Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Annual Meeting Optical Society of America

Squeezed vacuum enhanced interferometry at the dark fringe

P. Granger, Richard E. Slusher, Arthur LaPorta

Published Jan 1, 1988• 0 citations
Publisher

Abstract

An experimental study of enhancement of interferometric sensitivity using squeezed vacuum fluctuations is described. By operating an interferometer at the dark fringe, large laser powers can be used for high sensitivity. It is possible to enhance the interferometric sensitivity beyond the shot-noise limit in the dark fringe arrangement by using an electrooptic modulator in the interferometer to vary the phase periodically away from the dark fringe. A detector at the dark output port can then operate at the shot-noise limit and detect phase imbalance at the sensitivity determined by power level at the bright output port.1 This shot-noise limit can be reduced further by illuminating the dark input port with squeezed vacuum, as demonstrated recently in balanced output port experiments.2,3 However, there are interesting limits to the sensitivity improvement expected in the dark fringe case.1 The experimental arrangement includes a polarization interferometer illuminated with 100 mW of 1.064-μm wavelength light from a Nd:YAG cw laser. Squeezed vacuum is generated by a KTP optical parametric amplifier. Experimental progress is reported at sensitivities in the nanoradian polarization rotation range.

DOI
10.1364/oam.1988.mm6

Related papers

Squeezed state enhanced polarization Interferometry

Philippe Grangier, Bernard Yurke, Richard E. Slusher

Since the first proposal by Caves1 that squeezed light could be used to enhance the sensitivity of a gravitational wave interferometric antenna, squeezed states have been demonstrated in the laboratory but not yet used in an actual measurement system. This paper describes a polarization interferometer experiment, operated with a squeezed light source, designed to improve the interferometer sensitivity beyond the standard quantum limit. The interferometer consists of two polarization beam splitters, whose axes are oriented 45° with respect to each other. Linearly polarized incident laser light is transmitted by the first polarizer and split by the second one, which also acts as the splitter for a balanced homodyne detector. A rotation of the polarization between the two polarizers can be detected with quantum-limited sensitivity (e.g., ±1 μrad). The squeezed light entering the other port of the interferometer is produced using a χ2 crystal (KTP) in an optical cavity, pumped by a frequency-doubled cw ring Nd:YAG laser. The interferometer sensitivity can thus be increased by a factor depending on the degree of squeezing achieved and on the detector quantum efficiency. Sensitivity increases by factors between 2 and 3 are predicted, and current performance is described.

Annual Meeting Optical Society of America•Jan 1, 1987•0 citations

Sub-Shot Noise Interferometry and Quantum Imaging

Richard E. Slusher, Arthur La Porta, Philippe Grangier +2 more

Optimizing the sensitivity for interferometric measurement of optical phase involves maximizing the intensity of the illuminating light source and minimizing any noise sources. Limits to the light source intensity may arise from the availability of a stable high-power laser or from damage to the system being measured. For example, we describe here a scanning confocal polarization microscope designed to image the dynamics of nerve networks. In this case the light intensity limit is set by several factors, including the scanning rate, the required response time and damage limits of the biological system. Assuming a stable experimental configuration for the interferometer and light source, the limiting noise source for visible light interferometry is shot-noise associated with the quantum state of the light inputs to the interferometer. Shot-noise can be thought of as arising from vacuum fluctuations entering the dark input port of the interferometer.(1) These vacuum field fluctuations combine with the light entering the other port to cause shot-noise in the detected photocurrent at the output ports of the interferometer. This shot-noise current normally limits the measured phase variance Δϕ to a value of 1/N where N is the average number of photons detected in a measurement interval. We describe an experiment which demonstrates that this shot-noise limit can be improved by injecting squeezed vacuum into the normally dark input port.(2) In this case the phase variance is reduced below the 1/N limit by the degree of squeezing. In contrast to early experiments,(2) we are now operating the interferometer in a dark fringe mode(3–5) in order to avoid setting a limit to the light level caused by detector saturation (near 1 mW).

Topical Meeting on Quantum-Limited Imaging and Image Processing•Jan 1, 1989•0 citations

Application of squeezed-state light to high-precision interferometry

Carlton M. Caves

A potential application of squeezed-state light is to improve the sensitivity of high-precision interferometers whose performance is generally limited by photon shot noise or photon-counting statistics. Such interferometers include passive laser gyroscopes and the very sensitive interferometers being developed to detect cosmic gravitational waves. One usually operates a high-precision interferometer in a differential mode, so that noise from the (laser) light source is in principle irrelevant. Operation in a differential mode means that there is a second, normally unused input port. Vacuum noise entering this second port is responsible for the irreducible photon shot noise at the interferometer’s output. Injecting squeezed-state light into the normally unused input port can improve the sensitivity. I discuss the use of squeezed-state light in ring interferometers, delayline Michelson interferometers, and Fabry-Perot interferometers. Included in the discussion are real degrading effects, such as losses, inefficient photodetectors, and laser noise in the presence of nonideal fringe contrast. I explore the compatibility of the squeezed-state technique with other exotic techniques for improving sensitivity, such as Drever's idea for power recycling. Sensitivity estimates for various configurations and techniques are presented.

Annual Meeting Optical Society of America•Jan 1, 1986•1 citation

Squeezed-light – enhanced polarization interferometer

Philippe Grangier, Richard E. Slusher, Bernard Yurke +1 more

Enhancement of the sensitivity of a polarization interferometer beyond the limit set by vacuum fluctuations of the electromagnetic field has been obtained with use of squeezed light generated by a ${\mathrm{KTiOPO}}_{4}$ optical parametric amplifier. The increase in signal-to-noise ratio relative to the shot-noise limit is 2 dB. The corresponding improvement in the response time of the interferometer is measured to be a factor of 1.6.

Physical Review Letters•Nov 9, 1987•499 citations

Loss-tolerant interferometry with squeezed light

Maria V. Chekhova, Gaetano Frascella, Sascha Agne +1 more

An important part of optical sensing is interferometry, where direct or homodyne detection at the output of an interferometer yields information about small phase shifts. Classical interferometry operates at the shot-noise limit (SNL), caused by the photon structure of light and reached when an interferometer is fed with coherent light. The use of nonclassical light at the input of an interferometer enables overcoming the SNL. In particular, squeezed light is known to be less noisy than coherent light. An interferometer fed with strongly squeezed light can, in principle, provide the phase sensitivity at the Heisenberg limit, the ultimate limit allowed by the laws of physics. However, this supersensitive operation is strongly degraded by loss – both inside the interferometer and outside it, at the stage of detection. While the former (internal loss) seems to be inevitable, the latter (detection loss) can be overcome, and we demonstrate it in our recent experiment. The clue is to amplify light at the interferometer output using a phase-sensitive optical parametric amplifier. This device does not introduce additional noise, but it amplifies the fragile quantum signal and thus makes it tolerant to loss at the detection stage. In a proof-of-principle experiment, we build a polarization Mach-Zehnder interferometer and feed it with coherent light in one port and a squeezed vacuum in another port. At one output port, we amplify light with an optical parametric amplifier and measure a phase sensitivity of 13 mrad for 1500 photons in the interferometer. This result, achieved with 50% detection efficiency, overcomes the SNL by 3 dB. Moreover, by using stronger amplification, we can overcome the SNL under detection efficiency as low as 13%. Our results outline a way to use squeezed light for real-life sensing, where the detection efficiency cannot be very high, especially in spectral ranges like middle-infrared or terahertz.

Emerging Imaging and Sensing Technologies for Security and Defence; and Advanced Manufacturing Technologies for Micro- and Nanosystems in Security and Defence•Sep 18, 2020•0 citations

Broadening the high sensitivity range of squeezing-assisted interferometers by means of two-channel detection

Gaurav K. Shukla, Dariya Salykina, Gaetano Frascella +3 more

For a squeezing-enhanced linear (so-called SU(2)) interferometer, we theoretically investigate the possibility to broaden the phase range of sub-shot-noise sensitivity. We show that this goal can be achieved by implementing detection in both output ports, with the optimal combination of the detectors outputs. With this modification, the interferometer has the phase sensitivity independent of the interferometer operation point and, similar to the standard dark port regime, is not affected by the laser technical (excess) noise. Provided that each detector is preceded by a phase-sensitive amplifier, this sensitivity could be also tolerant to the detection loss.

arXiv:2010.05276•Optics Express•Dec 10, 2020•28 citations
An experimental study of enhancement of interferometric sensitivity using squeezed vacuum fluctuations is described. By operating an interferometer at the dark fringe, large laser powers can be used for high sensitivity. It is possible to enhance the interferometric sensitivity beyond the shot-noise limit in the dark fringe arrangement by using an electrooptic modulator in the interferometer to vary the phase periodically away from the dark fringe. A detector at the dark output port can then operate at the shot-noise limit and detect phase imbalance at the sensitivity determined by power level at the bright output port.1 This shot-noise limit can be reduced further by illuminating the dark input port with squeezed vacuum, as demonstrated recently in balanced output port experiments.2,3 However, there are interesting limits to the sensitivity improvement expected in the dark fringe case.1 The experimental arrangement includes a polarization interferometer illuminated with 100 mW of 1.064-μm wavelength light from a Nd:YAG cw laser. Squeezed vacuum is generated by a KTP optical parametric amplifier. Experimental progress is reported at sensitivities in the nanoradian polarization rotation range.
Since the first proposal by Caves1 that squeezed light could be used to enhance the sensitivity of a gravitational wave interferometric antenna, squeezed states have been demonstrated in the laboratory but not yet used in an actual measurement system. This paper describes a polarization interferometer experiment, operated with a squeezed light source, designed to improve the interferometer sensitivity beyond the standard quantum limit. The interferometer consists of two polarization beam splitters, whose axes are oriented 45° with respect to each other. Linearly polarized incident laser light is transmitted by the first polarizer and split by the second one, which also acts as the splitter for a balanced homodyne detector. A rotation of the polarization between the two polarizers can be detected with quantum-limited sensitivity (e.g., ±1 μrad). The squeezed light entering the other port of the interferometer is produced using a χ2 crystal (KTP) in an optical cavity, pumped by a frequency-doubled cw ring Nd:YAG laser. The interferometer sensitivity can thus be increased by a factor depending on the degree of squeezing achieved and on the detector quantum efficiency. Sensitivity increases by factors between 2 and 3 are predicted, and current performance is described.
Optimizing the sensitivity for interferometric measurement of optical phase involves maximizing the intensity of the illuminating light source and minimizing any noise sources. Limits to the light source intensity may arise from the availability of a stable high-power laser or from damage to the system being measured. For example, we describe here a scanning confocal polarization microscope designed to image the dynamics of nerve networks. In this case the light intensity limit is set by several factors, including the scanning rate, the required response time and damage limits of the biological system. Assuming a stable experimental configuration for the interferometer and light source, the limiting noise source for visible light interferometry is shot-noise associated with the quantum state of the light inputs to the interferometer. Shot-noise can be thought of as arising from vacuum fluctuations entering the dark input port of the interferometer.(1) These vacuum field fluctuations combine with the light entering the other port to cause shot-noise in the detected photocurrent at the output ports of the interferometer. This shot-noise current normally limits the measured phase variance Δϕ to a value of 1/N where N is the average number of photons detected in a measurement interval. We describe an experiment which demonstrates that this shot-noise limit can be improved by injecting squeezed vacuum into the normally dark input port.(2) In this case the phase variance is reduced below the 1/N limit by the degree of squeezing. In contrast to early experiments,(2) we are now operating the interferometer in a dark fringe mode(3–5) in order to avoid setting a limit to the light level caused by detector saturation (near 1 mW).
A potential application of squeezed-state light is to improve the sensitivity of high-precision interferometers whose performance is generally limited by photon shot noise or photon-counting statistics. Such interferometers include passive laser gyroscopes and the very sensitive interferometers being developed to detect cosmic gravitational waves. One usually operates a high-precision interferometer in a differential mode, so that noise from the (laser) light source is in principle irrelevant. Operation in a differential mode means that there is a second, normally unused input port. Vacuum noise entering this second port is responsible for the irreducible photon shot noise at the interferometer’s output. Injecting squeezed-state light into the normally unused input port can improve the sensitivity. I discuss the use of squeezed-state light in ring interferometers, delayline Michelson interferometers, and Fabry-Perot interferometers. Included in the discussion are real degrading effects, such as losses, inefficient photodetectors, and laser noise in the presence of nonideal fringe contrast. I explore the compatibility of the squeezed-state technique with other exotic techniques for improving sensitivity, such as Drever's idea for power recycling. Sensitivity estimates for various configurations and techniques are presented.
Enhancement of the sensitivity of a polarization interferometer beyond the limit set by vacuum fluctuations of the electromagnetic field has been obtained with use of squeezed light generated by a KTiOPO4{\mathrm{KTiOPO}}_{4}KTiOPO4​ optical parametric amplifier. The increase in signal-to-noise ratio relative to the shot-noise limit is 2 dB. The corresponding improvement in the response time of the interferometer is measured to be a factor of 1.6.
An important part of optical sensing is interferometry, where direct or homodyne detection at the output of an interferometer yields information about small phase shifts. Classical interferometry operates at the shot-noise limit (SNL), caused by the photon structure of light and reached when an interferometer is fed with coherent light. The use of nonclassical light at the input of an interferometer enables overcoming the SNL. In particular, squeezed light is known to be less noisy than coherent light. An interferometer fed with strongly squeezed light can, in principle, provide the phase sensitivity at the Heisenberg limit, the ultimate limit allowed by the laws of physics. However, this supersensitive operation is strongly degraded by loss – both inside the interferometer and outside it, at the stage of detection. While the former (internal loss) seems to be inevitable, the latter (detection loss) can be overcome, and we demonstrate it in our recent experiment. The clue is to amplify light at the interferometer output using a phase-sensitive optical parametric amplifier. This device does not introduce additional noise, but it amplifies the fragile quantum signal and thus makes it tolerant to loss at the detection stage. In a proof-of-principle experiment, we build a polarization Mach-Zehnder interferometer and feed it with coherent light in one port and a squeezed vacuum in another port. At one output port, we amplify light with an optical parametric amplifier and measure a phase sensitivity of 13 mrad for 1500 photons in the interferometer. This result, achieved with 50% detection efficiency, overcomes the SNL by 3 dB. Moreover, by using stronger amplification, we can overcome the SNL under detection efficiency as low as 13%. Our results outline a way to use squeezed light for real-life sensing, where the detection efficiency cannot be very high, especially in spectral ranges like middle-infrared or terahertz.
For a squeezing-enhanced linear (so-called SU(2)) interferometer, we theoretically investigate the possibility to broaden the phase range of sub-shot-noise sensitivity. We show that this goal can be achieved by implementing detection in both output ports, with the optimal combination of the detectors outputs. With this modification, the interferometer has the phase sensitivity independent of the interferometer operation point and, similar to the standard dark port regime, is not affected by the laser technical (excess) noise. Provided that each detector is preceded by a phase-sensitive amplifier, this sensitivity could be also tolerant to the detection loss.