Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Annual Meeting Optical Society of America

Partially coherent squeezed light: generation and detection

Prem Kumar, Orhan Aytür

Published Jan 1, 1989• 0 citations
Publisher

Abstract

Squeezed light with partial coherence is generated via optical parametric amplification (OPA) in a KTiOPO4 crystal that is pumped by the second harmonic of a Q-switched multimode Nd:YAG laser.1 More than 1 dB of squeezing is observed when a proper mode of the downconverted light is homodyned with the 380-ns multilongitudinal-mode local oscillator (LO) pulse. In such a system, large OPA gain is easily obtained in a single-crystal signal-pass setup. The detection of squeezed light is, however, not straightforward. In the usual implementation of a balanced homodyne detection scheme,2 the vacuum-noise level, as measured on a radio frequency spectrum analyzer, is determined by the average LO power. If the LO is derived from a Q-switched laser, as is the case in our experiment, the associated peak power can easily saturate the detectors and the subsequent electronics. To overcome this limitation, we have implemented a hybrid frequency/time domain measurement scheme in which the vacuum noise level is determined by the peak (instead of the average) LO power. The LO average power requirement is thus relaxed and the detector saturation problem avoided.

DOI
10.1364/oam.1989.thii2

Related papers

Pulsed squeezed-light measurement: a new technique

Orhan Aytür, Prem Kumar

A transient noise measurement scheme is described to observe pulsed squeezing generated by means of parametric downconversion of a Q-switched laser. In the usual implementation of balanced-homodyne detection, the vacuumstate noise level is determined by the average local oscillator power. However, if the local oscillator is derived from a pulsed laser, as is the case in our experiments, the associated peak power can easily saturate the detectors along with the subsequent electronics. To overcome this limitation we have implemented a hybrid frequency-time-domain measurement scheme in which the vacuum-state noise level is determined by the peak, instead of the average, local oscillator power, thus avoiding the saturation problem.

Optics Letters•Apr 1, 1990•22 citations

Quantum-noise reduction with a Q-switched laser

Orhan Aytür, Prem Kumar

Pulsed squeezed light and intensity-correlated twin beams are generated by means of a traveling-wave optical parametric amplifier (OPA) consisting of a type-II phase-matched KTiOPO4 crystal that is pumped by a Q-switched and frequency-doubled Nd:YAG laser. Q switching of the laser results in a high peak pump intensity and a large peak parametric gain. Squeezed light is generated by amplifying the vacuum input field to the OPA, and it is detected by a balanced homodyne configuration that uses the fundamental beam of the laser as a local oscillator.1 Twin beams are generated by supplying a small input signal to the OPA. The amplified signal and idler beams are direct-detected individually and yield quantum-noise reduction when the two photocurrents are subtracted.

Annual Meeting Optical Society of America•Jan 1, 1990•0 citations

Squeezed-light generation with a mode-locked Q-switched laser and detection by using a matched local oscillator

Orhan Aytür, Prem Kumar

We report pulsed squeezed-light generation by means of an optical parametric downconverter that is pumped by the second harmonic of a mode-locked Q-switched laser. Using the fundamental beam of the laser as a local oscillator, we observe 2-dB squeezing for a parametric gain of 2.0. This local oscillator, however, is nonoptimal because of its spatiotemporal mode mismatch with the squeezed mode generated by the downconverter. We describe an experiment in which a matched local oscillator is generated with the use of an optical parametric amplifier that is pumped by the same laser as is the downconverter. In this case, 2-dB squeezing is observed for a parametric gain of 1.5. The present experimental setup is limited by the uncontrollable phase fluctuations that prohibit us from making squeezing measurements at higher parametric gains.

Optics Letters•Apr 1, 1992•43 citations

Multimode squeezed light generation and characterization

Alexander Chudakov, Vladislav Severin, Anastasia Poshevkina +5 more

Nowadays, the realization of quantum computations and communications based on continuous variables has attracted a significant attention due to a substantial expansion of the system dimensionality. The main progress in this area is attributed to the implementation of multimode systems based on squeezed states of light. One of the simplest ways to generate such states relies upon their producing in a single-pass optical parametric amplifier (OPA) using ultrafast pumping. However, for homodyne detection of such multimode states, the profile of the local oscillator (LO) must perfectly match the profile of the measured mode. Usually, this is not the case; therefore a proper treatment of multimode squeezing is required. In this work, we study both theoretically and experimentally the multimode squeezed light generated in type-0 and type-II OPA. We characterize such sources and investigate the degree of squeezing in dependence on the LO spectral profile, employing a pulse shaping technique. The theoretical analysis is performed using the Schmidt-mode theory. This work might have a significant impact on the realization of multimode quantum protocols

quant-pharXiv:2609.08591•Sep 9, 2026•1 citation

Theoretical and experimental study on methods for increasing squeezed level in the generation of squeezed light

Fei Feng, Wenyan Qu, Jiazheng Song +1 more

We demonstrate the methods for increasing the observed squeezing level in the generation of squeezed states of light at 1064 nm with periodically poled KTiOPO4 (PPKTP) crystal. We analyze the technical limits to the reduction of noise in the squeezed quadrature theoretically, including the intra-cavity loss of the optical parametric amplifier (OPA) cavity, the normalized amplitude, the detection frequency, and the mode matching on the balanced homodyning stage. To observe a high degree of squeezing, we improve the quality of mode matching into the OPA cavity and the mode cleaning (MC) cavity experimentally. By optimizing mode matching of the light into cavities, the finesse of the cavities would be higher in practice and the desirable spatial mode can be realized. As the intensity noise of the laser light reach the shot noise limit above the frequency of 1 MHz, which is sufficient for our experiment, so the MC cavity is incorporated to filter higher-order transverse modes of the local oscillator (LO) beam for the balanced homodyne detection. The experimental and theoretical results show that it is essential to optimize the mode matching efficiency to generate and detect high degree of squeezing otherwise an inefficiency mode matching will throw away the squeezing and transform the squeezed field into a vacuum field.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Aug 21, 2013•0 citations

Generation of low-frequency squeezed states

Liu Zeng-Jun, Zhai Ze-Hui, Sun Heng-Xin +1 more

Squeezed state of light is an important resource of optical measuerments below the shot noise limit and has been used to improve measurement sensitivity in many areas such as gravitational wave detection, especially in audio frequency region. Compared with the high-frequency squeezed states, the generation of the low-frequency squeezed states is more difficult, because it is limited by several technical noise sources. In this paper we report the observation of more than 2 dB of vacuum squeezing at 1064 nm in the gravitational-wave detection band down to 3 kHz with a double-resonant optical parametric oscillator (OPO). The OPO has a configuration of linear cavity consisting of an input coupling mirror with a transmission of 11% at 532 nm and an output coupling mirror with the transmission of 12% at 1064 nm. The nonlinear materials in the OPO is type-I periodically poled potassium titanyl phosphate (PPKTP) crystal which is chosen for this experiment due to its higher nonlinearity, broader phase matching temperature, and smaller photo-thermal effect. The OPO is pumped by the light of 532 nm from Nd: YVO4/KTP solid-state laser of maximum optical power 3 W. To avoid various noise coupled from the seed beam, the OPO is seeded by vacuum fluctuations instead of coherent field at the fundamental wavelength (1064 nm). A Pound-Drever-Hall (PDH) locking scheme is used to lock the OPO cavity length with the signal derived from the reflected pump beam, so as to lock the pump field and also lock the fundamental field. To make both the pump and seed beams resonant simultaneously, the temperature of the PPKTP is carefully adjusted. The squeezed state can be detected on a homodyne detection by interfering it with the local oscillator (LO) and detected by a balanced detector with two photodiodes (EXT500 T) but having the same quantum efficiency of 86% at 1064 nm. The subsequent electronic noise is analyzed with a low-frequency spectrum analyzer, which shows that the audio noise sources from lab enviroment, locking quality, escape efficiency, propagation loss, homodyne efficiency and detection efficiency have effect on the squeezing pruced by an OPO.

Acta Physica Sinica•Jan 1, 2016•2 citations
Squeezed light with partial coherence is generated via optical parametric amplification (OPA) in a KTiOPO4 crystal that is pumped by the second harmonic of a Q-switched multimode Nd:YAG laser.1 More than 1 dB of squeezing is observed when a proper mode of the downconverted light is homodyned with the 380-ns multilongitudinal-mode local oscillator (LO) pulse. In such a system, large OPA gain is easily obtained in a single-crystal signal-pass setup. The detection of squeezed light is, however, not straightforward. In the usual implementation of a balanced homodyne detection scheme,2 the vacuum-noise level, as measured on a radio frequency spectrum analyzer, is determined by the average LO power. If the LO is derived from a Q-switched laser, as is the case in our experiment, the associated peak power can easily saturate the detectors and the subsequent electronics. To overcome this limitation, we have implemented a hybrid frequency/time domain measurement scheme in which the vacuum noise level is determined by the peak (instead of the average) LO power. The LO average power requirement is thus relaxed and the detector saturation problem avoided.
A transient noise measurement scheme is described to observe pulsed squeezing generated by means of parametric downconversion of a Q-switched laser. In the usual implementation of balanced-homodyne detection, the vacuumstate noise level is determined by the average local oscillator power. However, if the local oscillator is derived from a pulsed laser, as is the case in our experiments, the associated peak power can easily saturate the detectors along with the subsequent electronics. To overcome this limitation we have implemented a hybrid frequency-time-domain measurement scheme in which the vacuum-state noise level is determined by the peak, instead of the average, local oscillator power, thus avoiding the saturation problem.
Pulsed squeezed light and intensity-correlated twin beams are generated by means of a traveling-wave optical parametric amplifier (OPA) consisting of a type-II phase-matched KTiOPO4 crystal that is pumped by a Q-switched and frequency-doubled Nd:YAG laser. Q switching of the laser results in a high peak pump intensity and a large peak parametric gain. Squeezed light is generated by amplifying the vacuum input field to the OPA, and it is detected by a balanced homodyne configuration that uses the fundamental beam of the laser as a local oscillator.1 Twin beams are generated by supplying a small input signal to the OPA. The amplified signal and idler beams are direct-detected individually and yield quantum-noise reduction when the two photocurrents are subtracted.
We report pulsed squeezed-light generation by means of an optical parametric downconverter that is pumped by the second harmonic of a mode-locked Q-switched laser. Using the fundamental beam of the laser as a local oscillator, we observe 2-dB squeezing for a parametric gain of 2.0. This local oscillator, however, is nonoptimal because of its spatiotemporal mode mismatch with the squeezed mode generated by the downconverter. We describe an experiment in which a matched local oscillator is generated with the use of an optical parametric amplifier that is pumped by the same laser as is the downconverter. In this case, 2-dB squeezing is observed for a parametric gain of 1.5. The present experimental setup is limited by the uncontrollable phase fluctuations that prohibit us from making squeezing measurements at higher parametric gains.
Nowadays, the realization of quantum computations and communications based on continuous variables has attracted a significant attention due to a substantial expansion of the system dimensionality. The main progress in this area is attributed to the implementation of multimode systems based on squeezed states of light. One of the simplest ways to generate such states relies upon their producing in a single-pass optical parametric amplifier (OPA) using ultrafast pumping. However, for homodyne detection of such multimode states, the profile of the local oscillator (LO) must perfectly match the profile of the measured mode. Usually, this is not the case; therefore a proper treatment of multimode squeezing is required. In this work, we study both theoretically and experimentally the multimode squeezed light generated in type-0 and type-II OPA. We characterize such sources and investigate the degree of squeezing in dependence on the LO spectral profile, employing a pulse shaping technique. The theoretical analysis is performed using the Schmidt-mode theory. This work might have a significant impact on the realization of multimode quantum protocols
We demonstrate the methods for increasing the observed squeezing level in the generation of squeezed states of light at 1064 nm with periodically poled KTiOPO4 (PPKTP) crystal. We analyze the technical limits to the reduction of noise in the squeezed quadrature theoretically, including the intra-cavity loss of the optical parametric amplifier (OPA) cavity, the normalized amplitude, the detection frequency, and the mode matching on the balanced homodyning stage. To observe a high degree of squeezing, we improve the quality of mode matching into the OPA cavity and the mode cleaning (MC) cavity experimentally. By optimizing mode matching of the light into cavities, the finesse of the cavities would be higher in practice and the desirable spatial mode can be realized. As the intensity noise of the laser light reach the shot noise limit above the frequency of 1 MHz, which is sufficient for our experiment, so the MC cavity is incorporated to filter higher-order transverse modes of the local oscillator (LO) beam for the balanced homodyne detection. The experimental and theoretical results show that it is essential to optimize the mode matching efficiency to generate and detect high degree of squeezing otherwise an inefficiency mode matching will throw away the squeezing and transform the squeezed field into a vacuum field.
Squeezed state of light is an important resource of optical measuerments below the shot noise limit and has been used to improve measurement sensitivity in many areas such as gravitational wave detection, especially in audio frequency region. Compared with the high-frequency squeezed states, the generation of the low-frequency squeezed states is more difficult, because it is limited by several technical noise sources. In this paper we report the observation of more than 2 dB of vacuum squeezing at 1064 nm in the gravitational-wave detection band down to 3 kHz with a double-resonant optical parametric oscillator (OPO). The OPO has a configuration of linear cavity consisting of an input coupling mirror with a transmission of 11% at 532 nm and an output coupling mirror with the transmission of 12% at 1064 nm. The nonlinear materials in the OPO is type-I periodically poled potassium titanyl phosphate (PPKTP) crystal which is chosen for this experiment due to its higher nonlinearity, broader phase matching temperature, and smaller photo-thermal effect. The OPO is pumped by the light of 532 nm from Nd: YVO4/KTP solid-state laser of maximum optical power 3 W. To avoid various noise coupled from the seed beam, the OPO is seeded by vacuum fluctuations instead of coherent field at the fundamental wavelength (1064 nm). A Pound-Drever-Hall (PDH) locking scheme is used to lock the OPO cavity length with the signal derived from the reflected pump beam, so as to lock the pump field and also lock the fundamental field. To make both the pump and seed beams resonant simultaneously, the temperature of the PPKTP is carefully adjusted. The squeezed state can be detected on a homodyne detection by interfering it with the local oscillator (LO) and detected by a balanced detector with two photodiodes (EXT500 T) but having the same quantum efficiency of 86% at 1064 nm. The subsequent electronic noise is analyzed with a low-frequency spectrum analyzer, which shows that the audio noise sources from lab enviroment, locking quality, escape efficiency, propagation loss, homodyne efficiency and detection efficiency have effect on the squeezing pruced by an OPO.