We study the photon counting noise in optical interferometers used for gravitational wave detection. In order to reduce quantum noise a squeezed vacuum state is injected into the usually unused input port. Here, we specifically investigate the so-called “dark port case,” when the beam splitter is oriented close to 90° to the incoming laser beam, such that nearly all photons go to one output port of the interferometer, and only a small fraction of photons is seen in the other port (“dark port”). For this case it had been suggested that signal amplification is possible without concurrent noise amplification [R. Barak and Y. Ben-Aryeh, J. Opt. Soc. Am. B 25 , 361 (2008)]. We show that by injection of a squeezed vacuum state into the second input port, counting noise is reduced for large values of the squeezing factor, however the signal is not amplified. Signal strength only depends on the intensity of the laser beam.
We study the photon counting noise in optical interferometers used for gravitational wave detection. In order to reduce quantum noise, a squeezed vacuum is injected into the usually unused input port. It is investigated under which conditions the gravitational wave signal may be amplified without increasing counting noise concurrently. Such a possibility was suggested as a consequence of the entanglement of the two output ports of a beam splitter. We find that amplification without concurrent increase of noise is not possible for reasonable squeezing parameters. Photon distributions for various beam splitter angles and squeezing parameters are calculated.
The interferometers now being developed to detect gravitational waves work by measuring the relative positions of widely separated masses. Two fundamental sources of quantum-mechanical noise determine the sensitivity of such an interferometer: (i) fluctuations in number of output photons (photon-counting error) and (ii) fluctuations in radiation pressure on the masses (radiation-pressure error). Because of the low power of available continuous-wave lasers, the sensitivity of currently planned interferometers will be limited by photon-counting error. This paper presents an analysis of the two types of quantum-mechanical noise, and it proposes a new technique---the "squeezed-state" technique---that allows one to decrease the photon-counting error while increasing the radiation-pressure error, or vice versa. The key requirement of the squeezed-state technique is that the state of the light entering the interferometer's normally unused input port must be not the vacuum, as in a standard interferometer, but rather a "squeezed state"---a state whose uncertainties in the two quadrature phases are unequal. Squeezed states can be generated by a variety of nonlinear optical processes, including degenerate parametric amplification.
Quantum noise limits high-precision sensing, such as in gravitational wave detectors. Caves first proposed beating this shot-noise limit by injecting squeezed vacuum at the dark port of an interferometer. Frequency-dependent squeezing through a filter cavity now delivers broadband quantum noise reductions of up to 5.2 dB at Hanford and 6.1 dB at Livingston in the LIGO detectors' fourth observing run. Building on these advances, this thesis develops techniques for interferometric sensing under realistic loss and phase noise, spanning Gaussian state preparation, optomechanical readout and feedback control, and non-Gaussian state preparation. In Parts I and II, we work in the two-photon formalism, where states are Gaussian and dynamics are linear. In Part I, we present a waveguide squeezer as an alternative to the traditional bulk cavity-based source; it is single-pass, broadband, and compact, and its modularity opens a path to non-Gaussian state generation. We report the detection of squeezed light from waveguide sources at 1064 nm in the sub-MHz regime, and we phase-stabilize the squeezed vacuum with quantum noise locking. We also analyze the loss and phase-noise tolerance of Gaussian states. In Part II, we design a tabletop phase-sensitive optomechanical amplifier and analyze its performance in terms of cavity stability, control system, and noise budget. We then implement the locking scheme, including Pound-Drever-Hall locking of the cavity, and characterize the noise budget at the initial stage. We also propose using optomechanics for coherent feedback control, which could evade back-action and broaden the detection bandwidth of future gravitational wave detectors. In Part III, we turn to non-Gaussian states. Phase noise does not preserve Gaussianity, so the best input state under combined loss and phase noise need not be Gaussian. We numerically optimize the input state for displacement sensing over the
(η,σϕ) landscape, integrating the Lindblad master equation in a truncated Fock basis and computing the quantum Fisher information. Within the Gaussian sub-family, the optimizer returns a displaced squeezed state once phase noise is appreciable, rather than pure squeezed vacuum. Without the Gaussian restriction, the optimized states sort roughly into four classes (Fock-like, cubic-phase-like, discrete-rotational, and squeezed), each dominant in a different region of the parameter space. In the experimentally relevant region of 1% loss and 100 mrad phase noise, cat states outperform squeezed vacuum even with balanced homodyne readout, an improvement implementable in the near term. We also show that the non-Gaussian advantage persists at higher photon budgets, well above
Nˉ=5. Together, these results show how state preparation, readout, and feedback choices trade off against realistic loss and phase noise, and identify the regimes where non-Gaussian states perform better.
Quantum noise will be the dominant noise source for the advanced laser interferometric gravitational wave detectors currently under construction. Squeezing-enhanced laser interferometers have been recently demonstrated as a viable technique to reduce quantum noise. We propose two new methods of generating an error signal for matching the longitudinal phase of squeezed vacuum states of light to the phase of the laser interferometer output field. Both provide a superior signal to the one used in previous demonstrations of squeezing applied to a gravitational-wave detector. We demonstrate that the new signals are less sensitive to misalignments and higher order modes, and result in an improved stability of the squeezing level. The new signals also offer the potential of reducing the overall rms phase noise and optical losses, each of which would contribute to achieving a higher level of squeezing. The new error signals are a pivotal development towards realizing the goal of 6 dB and more of squeezing in advanced detectors and beyond.