Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Annual Meeting Optical Society of America

Beads on a string: experiments with a linear rf ion trap

Mark G. Raizen, Jonas Bergquist, Jonathan Magnolia Gilligan, Wayne M. Itano, D. J. Wineland

Published Jan 1, 1991• 0 citations
Publisher

Abstract

Trapping and cooling large numbers of ions, each confined to much less than an optical wavelength, is of great interest for high accuracy spectroscopy, improved frequency standards and atom-radiation field experiments. This can be achieved in a linear rf ion trap where the rf electric fields go to zero along a line rather than at only a point. As a step toward this goal we have constructed a linear trap and have observed simple crystallized linear structures of up to tens of 199Hg+ ions. By varying the axial well depth (determined by a static potential) we have also observed more complex crystallized structures. The ion positions in these structures are in close agreement with a calculation that used as input the measured secular frequencies of the trap. We have also observed the 40.5-GHz ground-state hyperfine transition of trapped 199Hg+ ions by microwave/optical double resonance.

DOI
10.1364/oam.1991.tujj4

Related papers

Linear Trap for High-accuracy Spectroscopy of Stored Ions

Mark G. Raizen, Jonathan Magnolia Gilligan, Jonas Bergquist +2 more

In a linear r.f. Paul trap, ‘crystallized’ structures of laser-cooled 199Hg+ ions are observed. The ground-state hyperfine transition at 40·5 GHz is observed in microwave-optical double-resonance spectroscopy. Future prospects are also discussed.

Journal of Modern Optics•Feb 1, 1992•93 citations

Cryogenic linear ion trap for accurate spectroscopy

Martin E. Poitzsch, Jonas Bergquist, Wayne M. Itano +1 more

We have observed linear ‘‘crystals’’ of up to tens of laser-cooled 199Hg+ ions in a linear rf ion trap. The trap operates at liquid-He temperature and is designed for use as a prototype 40.5 GHz frequency standard with high accuracy and stability.

Review of Scientific Instruments•Jan 1, 1996•66 citations

Ionic crystals in a linear Paul trap

Mark G. Raizen, Jonathan Magnolia Gilligan, Jonas Bergquist +2 more

We describe a configuration for a linear Paul rf ion trap. This trap can store a long string of ions with a small second-order Doppler shift, comparable to that achieved with a single ion in a quadrupole Paul trap. Crystallized strings of trapped ions, as well as more complicated structures, have been observed in the trap. We report an observation of the 40.5-GHz ground-state hyperfine interval of $^{199}\mathrm{Hg}^{+}$ by microwave-optical double-resonance spectroscopy and discuss prospects for a microwave frequency standard based on a trapped string of ions.

Physical Review A•May 1, 1992•343 citations

A cryogenic linear ion trap for /sup 199/Hg/sup +/ frequency standards

J.D. Miller, M.E. Poitzsch, Flávio C. Cruz +4 more

A cryogenic linear rf trap has been constructed to study the accuracy of a clock based on laser cooled /sup 199/Hg/sup +/. Crystals of tens of ions have been observed. The residual micromotion of the ions has been minimized and Ramsey interrogation periods of 25 s have been demonstrated for the 40.5 GHz transition. This system should eventually provide a frequency standard of high precision and accuracy. We report on the development of compact, efficient, solid-state sources at 194 nm and 282 nm for laser cooling of /sup 199/Hg/sup +/ and investigation of the /sup 2/S/sub 1/2//spl rarr//sup 2/D/sub 5/2/ quadrupole transition of interest for an optical frequency standard.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Nov 19, 2002•0 citations

Progress on a cryogenic linear trap for /sup 199/Hg/sup +/ ions

Martin E. Poitzsch, T.J.C. Bergquist, Wayne M. Itano +1 more

We have observed linear "crystals" of up to tens of laser-cooled /sup 199/Hg/sup +/ ions in a new cryogenic linear rf ion trap that operates at liquid helium temperature and is designed for use as a prototype 40.5 GHz frequency standard with high accuracy and stability.>

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Dec 17, 2002•1 citation

High-accuracy frequency standards using laser-cooled Hg+ ions

Dana J. Berkeland, J.D. Miller, Brent C. Young +3 more

We discuss frequency standards based on laser-cooled 199Hg+ ions confined in cryogenic rf traps. In one experiment, the frequency of a microwave source is served to the ions' ground-state hyperfine transition at 40.5 GHz. For seven ions and a Ramsey free precession time of 100 s, the fractional frequency stability is 3.3 (2) X 10-13 (tau) -1/2 for measurement times (tau) < 2 h. The ground-state hyperfine interval is measured to be 40 507 347 996.841 59 (14) (41) Hz, where the first number in parentheses is the uncertainty due to statistics and systematic errors, and the second is the uncertainty in the frequency of the time scale to which the standard is compared. In a second experiment under development, a strong-binding cryogenic trap will confine a single ion used for an optical frequency standard based on a narrow electric quadrupole transition at 282 nm. The bandwidth of the laser used to drive this transition is less than 10 Hz at 563 nm.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•May 15, 1998•1 citation
Trapping and cooling large numbers of ions, each confined to much less than an optical wavelength, is of great interest for high accuracy spectroscopy, improved frequency standards and atom-radiation field experiments. This can be achieved in a linear rf ion trap where the rf electric fields go to zero along a line rather than at only a point. As a step toward this goal we have constructed a linear trap and have observed simple crystallized linear structures of up to tens of 199Hg+ ions. By varying the axial well depth (determined by a static potential) we have also observed more complex crystallized structures. The ion positions in these structures are in close agreement with a calculation that used as input the measured secular frequencies of the trap. We have also observed the 40.5-GHz ground-state hyperfine transition of trapped 199Hg+ ions by microwave/optical double resonance.
We describe a configuration for a linear Paul rf ion trap. This trap can store a long string of ions with a small second-order Doppler shift, comparable to that achieved with a single ion in a quadrupole Paul trap. Crystallized strings of trapped ions, as well as more complicated structures, have been observed in the trap. We report an observation of the 40.5-GHz ground-state hyperfine interval of 199Hg+^{199}\mathrm{Hg}^{+}199Hg+ by microwave-optical double-resonance spectroscopy and discuss prospects for a microwave frequency standard based on a trapped string of ions.
A cryogenic linear rf trap has been constructed to study the accuracy of a clock based on laser cooled /sup 199/Hg/sup +/. Crystals of tens of ions have been observed. The residual micromotion of the ions has been minimized and Ramsey interrogation periods of 25 s have been demonstrated for the 40.5 GHz transition. This system should eventually provide a frequency standard of high precision and accuracy. We report on the development of compact, efficient, solid-state sources at 194 nm and 282 nm for laser cooling of /sup 199/Hg/sup +/ and investigation of the /sup 2/S/sub 1/2//spl rarr//sup 2/D/sub 5/2/ quadrupole transition of interest for an optical frequency standard.
We discuss frequency standards based on laser-cooled 199Hg+ ions confined in cryogenic rf traps. In one experiment, the frequency of a microwave source is served to the ions' ground-state hyperfine transition at 40.5 GHz. For seven ions and a Ramsey free precession time of 100 s, the fractional frequency stability is 3.3 (2) X 10-13 (tau) -1/2 for measurement times (tau) < 2 h. The ground-state hyperfine interval is measured to be 40 507 347 996.841 59 (14) (41) Hz, where the first number in parentheses is the uncertainty due to statistics and systematic errors, and the second is the uncertainty in the frequency of the time scale to which the standard is compared. In a second experiment under development, a strong-binding cryogenic trap will confine a single ion used for an optical frequency standard based on a narrow electric quadrupole transition at 282 nm. The bandwidth of the laser used to drive this transition is less than 10 Hz at 563 nm.