Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics & Laser Technology

High-sensitivity pump–probe atomic magnetometer based on single fiber-coupled

Binbin Zhao, Junjian Tang, Hongying Yang, Lin Li, Yaohua Zhang, Ying Liu, Yueyang Zhai

Published Dec 13, 2022• 25 citations
Publisher
DOI
10.1016/j.optlastec.2022.109025

Related papers

High sensitivity detuned single-light-source orthogonal pump-probe SERF atomic magnetometer

Yuhao Wang, Ying Liu, Ziqian Yue +4 more

Optics and Lasers in Engineering•Feb 10, 2025•2 citations

A two-color pump probe atomic magnetometer for magnetoencephalography

Cort Johnson, Peter D. D. Schwindt

In recent years, atomic magnetometers (AMs) have demonstrated sub-femtotesla sensitivities and have emerged as potential replacements for superconducting quantum interference devices (SQUIDs). In an AM, a circularly polarized pump laser aligns the electron spins in a cloud of alkali metal vapor. Changes occur in the optical properties of the vapor when its collective moment interacts with an external magnetic field, resulting in a measurable polarization rotation of a linearly polarized probe beam. We present a unique pump/probe scheme in which a pump beam tuned to the87Rb D1 line (795 nm) and a probe beam tuned to the D2 line (780 nm) share a single optical axis. A dichroic waveplate is used to circularly polarize the pump beam while leaving the probe beam linearly polarized. Based upon this scheme, we have developed a small profile, fiber-coupled AM. By independently optimizing pump/probe power and detuning, we are able to achieve intrinsic single-channel sensitivity of <; 5 fT/√Hz, which is suitable for demanding applications such as magnetoencephalography (MEG). Furthermore, through straightforward adaptations of the current design, it should be possible to create dense, reconfigurable arrays of AMs for whole-head MEG.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jun 1, 2010•17 citations

Sensitivity Improvement of Spin-Exchange Relaxation Free Atomic Magnetometers by Hybrid Optical Pumping of Potassium and Rubidium

Yosuke Ito, Hiroyuki Ohnishi, Keigo Kamada +1 more

An optically pumped atomic magnetometer using a hybrid cell of potassium and rubidium atoms was demonstrated to yield high sensitivity to magnetic fields. We operated the magnetometer with the four possible combinations of optically pumped and optically probed atoms and found that the combination of optically pumped potassium and optically probed rubidium showed the highest sensitivity among the four combinations because the rubidium atoms were denser than those of potassium. Furthermore, we investigated the dependence of the sensitivity on the power densities of the pump and probe beams and the wavelength of the probe beam. The magnetometer using the hybrid cell required higher pump-beam power and had narrower magnetic linewidth than those of the single alkali-metal cell. However, the magnetic linewidth was larger than the theoretical value, ignoring the spin relaxation caused by the spin-exchange collisions. By adjusting the laser conditions, the highest sensitivity approached 30 fTrms/Hz1/2.

IEEE Transactions on Magnetics•Oct 1, 2011•53 citations

Progress in high sensitive atomic magnetometers

Guobin Liu, Xian-Ping Sun, 顾思洪 +2 more

Wuli•Jan 1, 2012•1 citation

Miniaturized atomic magnetometer employing pump-beam modulation

Ziqian Yue, Junjian Tang, Yueyang Zhai

Atomic magnetometers with magnetic field modulation have emerged as pivotal sensors for biomagnetic measurements. However, challenges such as crosstalk between adjacent modulation fields and the complexity of signal circuitry become increasingly serious in the development of array-based equipment with the magnetometers, especially in the miniaturized atomic magnetometer. This paper proposes an all-optical, fully integrated fiber-coupled atomic magnetometer that employs pump beam modulation. A miniaturized atomic magnetometer with a volume of 10 cm³ has been designed, incorporating an active measurement area of 3 × 3 × 3 mm3. The magnetometer operates in the spinexchange relaxation-free (SERF) regime with an 87Rb vapor cell. An amplitude-modulated pump beam directly modulates the rubidium atomic ensembles, rather than the magnetic field modulation. The optical rotation angle is detected by an unmodulated probe beam oriented orthogonally to the pump beam. In light of the discontinuous pumping characteristics, we developed a modified theoretical model to clarify the output response of the proposed atomic magnetometer. The experimental results demonstrate that the new design achieves the same sensitivity as conventional magnetometer configurations with a smaller volume and without crosstalk of the magnetic field. This research highlights the significant potential for advancing the development of highly sensitive, miniaturized atomic magnetometers, making them particularly suitable for applications in magnetocardiography (MCG) and magnetoencephalography (MEG).

Advanced Sensor Systems and Applications•Oct 11, 2024•0 citations

A compact fiberized alkali-vapor atomic magnetometer

E. Zhivun, Brian Patton, Chris Hovde +1 more

Bulletin of the American Physical Society•Jun 5, 2012•0 citations
In recent years, atomic magnetometers (AMs) have demonstrated sub-femtotesla sensitivities and have emerged as potential replacements for superconducting quantum interference devices (SQUIDs). In an AM, a circularly polarized pump laser aligns the electron spins in a cloud of alkali metal vapor. Changes occur in the optical properties of the vapor when its collective moment interacts with an external magnetic field, resulting in a measurable polarization rotation of a linearly polarized probe beam. We present a unique pump/probe scheme in which a pump beam tuned to the87Rb D1 line (795 nm) and a probe beam tuned to the D2 line (780 nm) share a single optical axis. A dichroic waveplate is used to circularly polarize the pump beam while leaving the probe beam linearly polarized. Based upon this scheme, we have developed a small profile, fiber-coupled AM. By independently optimizing pump/probe power and detuning, we are able to achieve intrinsic single-channel sensitivity of <; 5 fT/√Hz, which is suitable for demanding applications such as magnetoencephalography (MEG). Furthermore, through straightforward adaptations of the current design, it should be possible to create dense, reconfigurable arrays of AMs for whole-head MEG.
An optically pumped atomic magnetometer using a hybrid cell of potassium and rubidium atoms was demonstrated to yield high sensitivity to magnetic fields. We operated the magnetometer with the four possible combinations of optically pumped and optically probed atoms and found that the combination of optically pumped potassium and optically probed rubidium showed the highest sensitivity among the four combinations because the rubidium atoms were denser than those of potassium. Furthermore, we investigated the dependence of the sensitivity on the power densities of the pump and probe beams and the wavelength of the probe beam. The magnetometer using the hybrid cell required higher pump-beam power and had narrower magnetic linewidth than those of the single alkali-metal cell. However, the magnetic linewidth was larger than the theoretical value, ignoring the spin relaxation caused by the spin-exchange collisions. By adjusting the laser conditions, the highest sensitivity approached 30 fTrms/Hz1/2.
Atomic magnetometers with magnetic field modulation have emerged as pivotal sensors for biomagnetic measurements. However, challenges such as crosstalk between adjacent modulation fields and the complexity of signal circuitry become increasingly serious in the development of array-based equipment with the magnetometers, especially in the miniaturized atomic magnetometer. This paper proposes an all-optical, fully integrated fiber-coupled atomic magnetometer that employs pump beam modulation. A miniaturized atomic magnetometer with a volume of 10 cm³ has been designed, incorporating an active measurement area of 3 × 3 × 3 mm3. The magnetometer operates in the spinexchange relaxation-free (SERF) regime with an 87Rb vapor cell. An amplitude-modulated pump beam directly modulates the rubidium atomic ensembles, rather than the magnetic field modulation. The optical rotation angle is detected by an unmodulated probe beam oriented orthogonally to the pump beam. In light of the discontinuous pumping characteristics, we developed a modified theoretical model to clarify the output response of the proposed atomic magnetometer. The experimental results demonstrate that the new design achieves the same sensitivity as conventional magnetometer configurations with a smaller volume and without crosstalk of the magnetic field. This research highlights the significant potential for advancing the development of highly sensitive, miniaturized atomic magnetometers, making them particularly suitable for applications in magnetocardiography (MCG) and magnetoencephalography (MEG).