An Actively Controlled Dual Species Rb Atomic Magnetometer for Low Frequency Communication.

Jonathan Bainbridge, N. R. Claussen, Joonas Iivanainen, Peter D. D. Schwindt

Published Oct 1, 2021• 0 citations
Publisher

Abstract

GoalCreate an RF magnetometer that can be used outside a magnetic shield as a high sensitivity receiver for very low frequency communication through lossy media. SAND2021-12583CThis paper describes objective technical results and analysis.Any subjective views or opinions that might be expressed in the paper do not necessarily represent the views of the U.S.

DOI
10.2172/1891426

Related papers

An Actively Controlled Dual Species Rb Atomic Magnetometer for Low Frequency Communication.

Jonathan Bainbridge, N. R. Claussen, Joonas Iivanainen +1 more

•Jul 1, 2021•0 citations

Optimization of a Radio-frequency Atomic Magnetometer Toward Very Low Frequency Signal Reception

Hyun Joon Lee, Ye-Jin Yu, Jang‐Yeol Kim +3 more

We describe a single-channel rubidium (Rb) radio-frequency atomic magnetometer (RFAM) as a receiver that takes magnetic signal resonating with Zeeman splitting of the ground state of Rb. We optimize the performance of the RFAM by recording the response signal and signal-to-noise ratio (SNR) in various parameters and obtain a noise level of 159 fT/Hz around 30 kHz. When a resonant radio-frequency magnetic field with a peak amplitude of 8.0 nT is applied, the bandwidth and signal-to-noise ratio are about 650 Hz and 88 dB, respectively. It is a good agreement that RFAM using alkali atoms is suitable for receiving signals in the very low frequency (VLF) carrier band, ranging from 3 kHz to 30 kHz. This study shows the new capabilities of the RFAM in communications applications based on magnetic signals with the VLF carrier band. Such communication can be expected to expand the communication space by overcoming obstacles through the high magnetic sensitive RFAM.

Current Optics and Photonics•Jun 25, 2021•2 citations

Dual-frequency operation in a single atomic magnetometer and frequency-shift keying modulation of magnetic field communication

Ye-Jin Yu, Han Seb Moon

We present a dual-frequency operation technique for a radio-frequency atomic magnetometer utilizing a single natural-abundance rubidium (Rb) vapor cell for the first time, and demonstrate a proof-of-concept for magnetic field communication using binary frequency-shift keying (BFSK) under unshielded conditions. The two operational frequencies correspond to the Larmor frequencies of 85 Rb and 87 Rb, as determined by their distinct gyromagnetic ratios in the same magnetic field environment. A rate of 400 symbols/s is adeptly demonstrated with an ambient noise floor of < 20 pT/√Hz, attaining a signal-to-noise ratio of 20 dB. These findings highlight the efficacy of dual-frequency atomic magnetometry as a sophisticated and resilient technique for magnetic field communication in unshielded environments.

Optics Express•Jun 17, 2025•3 citations

Ultra-sensitive high-density Rb-87 radio-frequency magnetometer

Igor Savukov, Todor S. Karaulanov, M. G. Boshier

Radio-frequency (RF) atomic magnetometers (AMs) can be used in many applications, such as magnetic resonance imaging and nuclear quadrupole resonance. High-density AMs provide both superior sensitivity and large bandwidth. Previously, high-density potassium AMs were demonstrated, but these magnetometers have various disadvantages, such as high-temperature of operation and bulky design. We demonstrate a rubidium-87 RF AM with 5 fT/Hz1/2 sensitivity (3 fT Hz1/2 probe noise), which is comparable to that of the best potassium magnetometers. Our magnetometer also features a simple fiber-optic design, providing maximum flexibility for magnetic-field measurements.

Applied Physics Letters•Jan 13, 2014•34 citations

Continuous High-Sensitivity and High-Bandwidth Atomic Magnetometer

Rujie Li, Fred N. Baynes, Andre Nicholas Luiten +1 more

Here we demonstrate an atomic magnetometer that has a bandwidth of more than 100 kHz and a sensitivity of $180\phantom{\rule{0.2em}{0ex}}\mathrm{fT/}\ensuremath{\surd}\mathrm{Hz}$ at a Fourier frequency of 8 Hz, and $0.7\phantom{\rule{0.2em}{0ex}}\mathrm{nT/}\ensuremath{\surd}\mathrm{Hz}$ at 100 kHz. These sensitivity measurements are achieved at geophysically useful magnetic field magnitudes (approximately $50\phantom{\rule{0.2em}{0ex}}\ensuremath{\mu}\mathrm{T}$ inside a three-layer $\ensuremath{\mu}$-metal shield) and are limited by the photon shot noise for frequencies above 8 Hz. This device is based on a nonlinear magneto-optical rotation sensor that is operated with an active feedback to the pump modulation frequency. We present a theoretical description of the response functions of the components in the magnetometer. We show that the range of operation of atomic magnetometers can thus be expanded beyond the conventional high-sensitivity, low-bandwidth domain, to provide a high-linearity, high-bandwidth, and high-sensitivity sensor.

Physical Review Applied•Dec 23, 2020•78 citations

High-sensitivity operation of an unshielded single cell radio-frequency atomic magnetometer

Han Yao, Benjamin Maddox, Ferruccio Renzoni

Real-world applications of atomic magnetometers require the ability to operate them with high-sensitivity in the presence of magnetic noise. In the present work, high-sensitivity operation of unshielded atomic magnetometers in a magnetically noisy environment is demonstrated. The distinguishing feature of the demonstrated approach is the implementation of active in-situ bias field stabilization using multiple fluxgate magnetometers. This is combined with the use of a counter-propagating pump and triple-pass probe configuration, to maximize the atomic polarization and the probe rotation respectively, so to reach high-sensitivity. The improvement in sensitivity of the unshielded system with respect to previous realizations is fully characterized, with the contributions of the different modifications of the apparatus individually quantified. The presented set-up is suitable for the detection of long-range magnetic fields, where shielding or differential measurements using multi-sensor set-ups do not constitute viable options.

Optics Express•Oct 21, 2022•31 citations
GoalCreate an RF magnetometer that can be used outside a magnetic shield as a high sensitivity receiver for very low frequency communication through lossy media. SAND2021-12583CThis paper describes objective technical results and analysis.Any subjective views or opinions that might be expressed in the paper do not necessarily represent the views of the U.S.
We describe a single-channel rubidium (Rb) radio-frequency atomic magnetometer (RFAM) as a receiver that takes magnetic signal resonating with Zeeman splitting of the ground state of Rb. We optimize the performance of the RFAM by recording the response signal and signal-to-noise ratio (SNR) in various parameters and obtain a noise level of 159 fT/Hz around 30 kHz. When a resonant radio-frequency magnetic field with a peak amplitude of 8.0 nT is applied, the bandwidth and signal-to-noise ratio are about 650 Hz and 88 dB, respectively. It is a good agreement that RFAM using alkali atoms is suitable for receiving signals in the very low frequency (VLF) carrier band, ranging from 3 kHz to 30 kHz. This study shows the new capabilities of the RFAM in communications applications based on magnetic signals with the VLF carrier band. Such communication can be expected to expand the communication space by overcoming obstacles through the high magnetic sensitive RFAM.
We present a dual-frequency operation technique for a radio-frequency atomic magnetometer utilizing a single natural-abundance rubidium (Rb) vapor cell for the first time, and demonstrate a proof-of-concept for magnetic field communication using binary frequency-shift keying (BFSK) under unshielded conditions. The two operational frequencies correspond to the Larmor frequencies of 85 Rb and 87 Rb, as determined by their distinct gyromagnetic ratios in the same magnetic field environment. A rate of 400 symbols/s is adeptly demonstrated with an ambient noise floor of < 20 pT/√Hz, attaining a signal-to-noise ratio of 20 dB. These findings highlight the efficacy of dual-frequency atomic magnetometry as a sophisticated and resilient technique for magnetic field communication in unshielded environments.
Radio-frequency (RF) atomic magnetometers (AMs) can be used in many applications, such as magnetic resonance imaging and nuclear quadrupole resonance. High-density AMs provide both superior sensitivity and large bandwidth. Previously, high-density potassium AMs were demonstrated, but these magnetometers have various disadvantages, such as high-temperature of operation and bulky design. We demonstrate a rubidium-87 RF AM with 5 fT/Hz1/2 sensitivity (3 fT Hz1/2 probe noise), which is comparable to that of the best potassium magnetometers. Our magnetometer also features a simple fiber-optic design, providing maximum flexibility for magnetic-field measurements.
Here we demonstrate an atomic magnetometer that has a bandwidth of more than 100 kHz and a sensitivity of $180\phantom{\rule{0.2em}{0ex}}\mathrm{fT/}\ensuremath{\surd}\mathrm{Hz}$ at a Fourier frequency of 8 Hz, and $0.7\phantom{\rule{0.2em}{0ex}}\mathrm{nT/}\ensuremath{\surd}\mathrm{Hz}$ at 100 kHz. These sensitivity measurements are achieved at geophysically useful magnetic field magnitudes (approximately $50\phantom{\rule{0.2em}{0ex}}\ensuremath{\mu}\mathrm{T}$ inside a three-layer $\ensuremath{\mu}$-metal shield) and are limited by the photon shot noise for frequencies above 8 Hz. This device is based on a nonlinear magneto-optical rotation sensor that is operated with an active feedback to the pump modulation frequency. We present a theoretical description of the response functions of the components in the magnetometer. We show that the range of operation of atomic magnetometers can thus be expanded beyond the conventional high-sensitivity, low-bandwidth domain, to provide a high-linearity, high-bandwidth, and high-sensitivity sensor.
Real-world applications of atomic magnetometers require the ability to operate them with high-sensitivity in the presence of magnetic noise. In the present work, high-sensitivity operation of unshielded atomic magnetometers in a magnetically noisy environment is demonstrated. The distinguishing feature of the demonstrated approach is the implementation of active in-situ bias field stabilization using multiple fluxgate magnetometers. This is combined with the use of a counter-propagating pump and triple-pass probe configuration, to maximize the atomic polarization and the probe rotation respectively, so to reach high-sensitivity. The improvement in sensitivity of the unshielded system with respect to previous realizations is fully characterized, with the contributions of the different modifications of the apparatus individually quantified. The presented set-up is suitable for the detection of long-range magnetic fields, where shielding or differential measurements using multi-sensor set-ups do not constitute viable options.