Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Chinese Physics B

Tolerance-enhanced SU(1,1) interferometers using asymmetric gain

Jiandong Zhang, Shuai Wang

Published Oct 7, 2022• 7 citations
Publisher

Abstract

SU(1,1) interferometers play an important role in quantum metrology. Previous studies focus on various inputs and detection strategies with symmetric gain. In this paper, we analyze a modified SU(1,1) interferometer using asymmetric gain. Two vacuum states are used as the input and on–off detection is performed at the output. In a lossless scenario, symmetric gain is the optimal selection and the corresponding phase sensitivity can achieve the Heisenberg limit as well as the quantum Cramer–Rao bound. In addition, we analyze the phase sensitivity with symmetric gain in the lossy scenario. The phase sensitivity is sensitive to internal losses but extremely robust against external losses. We address the optimal asymmetric gain and the results suggest that this method can improve the tolerance to internal losses. Our work may contribute to the practical development of quantum metrology.

DOI
10.1088/1674-1056/ac981d

Related papers

Phase sensitivity for an SU(1,1) interferometer via multiphoton subtraction at the output port

Tao Jiang, Zekun Zhao, Qingqian Kang +4 more

In the field of quantum precision measurement, enhancing phase sensitivity is crucial for various applications, including quantum metrology and quantum sensing technologies. We theoretically investigate the improvement in phase sensitivity and quantum Fisher information achieved through multiphoton subtraction operations at the output port of an SU(1,1) interferometer under conditions of photon loss. We use vacuum and coherent states as the inputs and detect the outputs by intensity detection. The results indicate that internal photon losses within the SU(1,1) interferometer have a more significant impact on the phase sensitivity compared to external photon losses. Moreover, increasing the number of photon subtractions m effectively enhances both the phase sensitivity and the quantum Fisher information. Notably, even under conditions of severe photon loss, the multiphoton subtraction operations can enable the phase sensitivity to surpass the standard quantum limit, approaching both the Heisenberg limit and the quantum Cramér-Rao bound. This study provides a new theoretical basis for enhancing the phase sensitivity in the SU(1,1) interferometer.

arXiv:2410.17612•Optics Express•Apr 14, 2025•8 citations

Sensitivity Evaluation of SU(1,1) Interferometers with Arbitrary Input Probe State and Homodyne Detections

Sonu Jana, Dhruv Baheti, Paul Grossiord +3 more

We provide a general theoretical derivation of the phase sensitivity achieved by SU(1,1) interferometers under homodyne detection. The general expressions obtained accommodate arbitrary input states and include internal and external losses. In this systematic review, both full SU(1,1) interferometers with two parametric amplifiers and the truncated interferometers with only one parametric amplifier are examined. We investigate scenarios involving both single-output ports and joint homodyne detection, and consider parametric amplifiers with equal gains or with a boosted gain second amplifier. Our analytical formulation provides physical insight and understanding of the improvements in the sensitivity, which are shown to originate from noise reduction and/or signal amplification, depending on the configurations and practical implementations. Surprisingly, the configuration with single-output mode detection and parametric amplifiers with equal gains exhibits the highest robustness to very high internal losses. We finally apply this framework to a ubiquitous $|α,0\rangle$ input two-mode coherent probe state. This approach permits the comparison of different strategies and the optimization of the interferometer performance in the presence of losses. In particular, we determine which amplification and detection configurations provide the best performance, depending on the level of losses. This exemplifies how this general analytical approach provides a powerful tool to design quantum-enhanced interferometers and achieve optimal sensitivity with selected probe states and homodyne detection.

quant-pharXiv:2605.22029•May 22, 2026•1 citation

Phase estimation of an SU(1,1) interferometer with superposition of even and odd coherent states

Abdelmajid El Maaroufi, Mouad Ait Maskour, Bouchra Maroufi +1 more

Abstract The SU(1,1) interferometer, a nonlinear analog of the traditional Mach–Zehnder interferometer, has emerged as a powerful tool for achieving phase sensitivity beyond the standard quantum limit. In this work, we propose the use of a superposition of even and odd coherent states as input state to enhance the phase sensitivity of an SU(1,1) interferometer. These non-classical states exhibit unique properties such as squeezing, entanglement, and quantum interference, which can be harnessed to improve metrological precision. Phase sensitivity is analyzed using single-intensity detection and homodyne detection schemes under both ideal and photon loss cases, which demonstrates significant improvements over classical and squeezed-vacuum inputs. In addition, we evaluate the quantum Cramér-Rao lower bound by employing the quantum Fisher information formalism, showing that it surpasses the standard quantum limit and approaches the Heisenberg limit under optimal conditions. Our results highlight the potential of the even and odd coherent states superposition in quantum metrology and provide a pathway for achieving ultra-precise phase measurements in SU(1,1) interferometers for applications in optical sensing, and quantum information processing.

Physica Scripta•Feb 25, 2026•0 citations

Enhancing Phase Sensitivity in a Lossy Atom-Light SU(1,1) Interferometer via Iterative Feedback

Yueya Liu, Wenfeng Huang, Liqing Chen +2 more

We propose an iterative atom-light SU(1,1) interferometer that optimizes phase sensitivity, beats the standard quantum limit under losses, closely approaches the quantum Cramér-Rao bound, and enhances robustness for practical quantum sensing. This research provides a new approach to addressing the performance degradation of quantum interferometers in lossy environments and contributes to promoting the robust application of quantum-enhanced measurement in practical lossy scenarios.

Conference on Lasers and Electro-Optics Pacific Rim (CLEO-PR)•Aug 1, 2026•0 citations

Quantum optical metrology in the lossy SU(2) and SU(1,1) interferometers

Yang Gao

We study the phase sensitivity in the conventional SU(2) and nonconventional SU(1,1) interferometers with a coherent and squeezed vacuum input state via quantum Cramer-Rao bound. We explicitly construct the detection scheme that gives the optimal phase sensitivity. For practical purposes, we show that in the presence of photon loss, both interferometers with proper homodyne detections are nearly optimal. We also find that unlike the coherent state and the squeezed vacuum state, the effects of imperfect detector on the phase sensitivity cannot be asymptotically removed for a generic coherent-squeezed state.

arXiv:1606.08966•Physical Review A•Aug 18, 2016•25 citations

The Super Phase Sensitivity of an SU(1,1) Interferometer with a Two-Mode Squeezed Coherent State via Balanced Homodyne and Intensity Detection

Changlan Xu, Lei Wang, Shaoqiu Ke +2 more

We propose a novel scheme that is used for the enhancement of phase sensitivity. The SU(1,1) interferometer with a two-mode squeezed coherent state input, using balanced homodyne detection (BHD) and intensity detection (ID), is shown. Our results demonstrate that the phase sensitivity achieved via BHD outperforms that of ID. The optimal phase sensitivity via BHD surpasses the Heisenberg limit (HL) and approaches the quantum Cramér–Rao bound. A larger photon number and parameter strength can make the phase sensitivity better. Furthermore, we show the effects of internal and external losses on phase sensitivity in detail. When external loss reaches 10%, the phase sensitivity can reach the HL. Next, we have a detailed discussion on the impact of the squeezing parameter and photon number on phase sensitivity, which shows that our scheme has better phase sensitivity and enhanced robustness. This interferometer system thus holds significant potential for applications in quantum precision measurement.

Photonics•Mar 23, 2026•1 citation
SU(1,1) interferometers play an important role in quantum metrology. Previous studies focus on various inputs and detection strategies with symmetric gain. In this paper, we analyze a modified SU(1,1) interferometer using asymmetric gain. Two vacuum states are used as the input and on–off detection is performed at the output. In a lossless scenario, symmetric gain is the optimal selection and the corresponding phase sensitivity can achieve the Heisenberg limit as well as the quantum Cramer–Rao bound. In addition, we analyze the phase sensitivity with symmetric gain in the lossy scenario. The phase sensitivity is sensitive to internal losses but extremely robust against external losses. We address the optimal asymmetric gain and the results suggest that this method can improve the tolerance to internal losses. Our work may contribute to the practical development of quantum metrology.
In the field of quantum precision measurement, enhancing phase sensitivity is crucial for various applications, including quantum metrology and quantum sensing technologies. We theoretically investigate the improvement in phase sensitivity and quantum Fisher information achieved through multiphoton subtraction operations at the output port of an SU(1,1) interferometer under conditions of photon loss. We use vacuum and coherent states as the inputs and detect the outputs by intensity detection. The results indicate that internal photon losses within the SU(1,1) interferometer have a more significant impact on the phase sensitivity compared to external photon losses. Moreover, increasing the number of photon subtractions m effectively enhances both the phase sensitivity and the quantum Fisher information. Notably, even under conditions of severe photon loss, the multiphoton subtraction operations can enable the phase sensitivity to surpass the standard quantum limit, approaching both the Heisenberg limit and the quantum Cramér-Rao bound. This study provides a new theoretical basis for enhancing the phase sensitivity in the SU(1,1) interferometer.
We provide a general theoretical derivation of the phase sensitivity achieved by SU(1,1) interferometers under homodyne detection. The general expressions obtained accommodate arbitrary input states and include internal and external losses. In this systematic review, both full SU(1,1) interferometers with two parametric amplifiers and the truncated interferometers with only one parametric amplifier are examined. We investigate scenarios involving both single-output ports and joint homodyne detection, and consider parametric amplifiers with equal gains or with a boosted gain second amplifier. Our analytical formulation provides physical insight and understanding of the improvements in the sensitivity, which are shown to originate from noise reduction and/or signal amplification, depending on the configurations and practical implementations. Surprisingly, the configuration with single-output mode detection and parametric amplifiers with equal gains exhibits the highest robustness to very high internal losses. We finally apply this framework to a ubiquitous ∣α,0⟩|α,0\rangle∣α,0⟩ input two-mode coherent probe state. This approach permits the comparison of different strategies and the optimization of the interferometer performance in the presence of losses. In particular, we determine which amplification and detection configurations provide the best performance, depending on the level of losses. This exemplifies how this general analytical approach provides a powerful tool to design quantum-enhanced interferometers and achieve optimal sensitivity with selected probe states and homodyne detection.
Abstract The SU(1,1) interferometer, a nonlinear analog of the traditional Mach–Zehnder interferometer, has emerged as a powerful tool for achieving phase sensitivity beyond the standard quantum limit. In this work, we propose the use of a superposition of even and odd coherent states as input state to enhance the phase sensitivity of an SU(1,1) interferometer. These non-classical states exhibit unique properties such as squeezing, entanglement, and quantum interference, which can be harnessed to improve metrological precision. Phase sensitivity is analyzed using single-intensity detection and homodyne detection schemes under both ideal and photon loss cases, which demonstrates significant improvements over classical and squeezed-vacuum inputs. In addition, we evaluate the quantum Cramér-Rao lower bound by employing the quantum Fisher information formalism, showing that it surpasses the standard quantum limit and approaches the Heisenberg limit under optimal conditions. Our results highlight the potential of the even and odd coherent states superposition in quantum metrology and provide a pathway for achieving ultra-precise phase measurements in SU(1,1) interferometers for applications in optical sensing, and quantum information processing.
We study the phase sensitivity in the conventional SU(2) and nonconventional SU(1,1) interferometers with a coherent and squeezed vacuum input state via quantum Cramer-Rao bound. We explicitly construct the detection scheme that gives the optimal phase sensitivity. For practical purposes, we show that in the presence of photon loss, both interferometers with proper homodyne detections are nearly optimal. We also find that unlike the coherent state and the squeezed vacuum state, the effects of imperfect detector on the phase sensitivity cannot be asymptotically removed for a generic coherent-squeezed state.
We propose a novel scheme that is used for the enhancement of phase sensitivity. The SU(1,1) interferometer with a two-mode squeezed coherent state input, using balanced homodyne detection (BHD) and intensity detection (ID), is shown. Our results demonstrate that the phase sensitivity achieved via BHD outperforms that of ID. The optimal phase sensitivity via BHD surpasses the Heisenberg limit (HL) and approaches the quantum Cramér–Rao bound. A larger photon number and parameter strength can make the phase sensitivity better. Furthermore, we show the effects of internal and external losses on phase sensitivity in detail. When external loss reaches 10%, the phase sensitivity can reach the HL. Next, we have a detailed discussion on the impact of the squeezing parameter and photon number on phase sensitivity, which shows that our scheme has better phase sensitivity and enhanced robustness. This interferometer system thus holds significant potential for applications in quantum precision measurement.