Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Quantum-limited measurements on trapped laser-cooled ions

Cassius D'Helon

Published Jan 1, 1997• 0 citations
Publisher
DOI
10.14264/8702bf9

Related papers

Quantum measurements of trapped ions

Wayne M. Itano, James C Bergquist, J. J. Bollinger +5 more

Vistas in Astronomy•Jan 1, 1993•4 citations

Broadband laser cooling of trapped atoms with ultrafast pulses

B. B. Blinov, R. N. Kohn, M. J. Madsen +3 more

We demonstrate broadband laser cooling of atomic ions in an rf trap using ultrafast pulses from a mode-locked laser. The temperature of a single ion is measured by observing the size of a time-averaged image of the ion in the known harmonic trap potential. Although the lowest observed temperature was only about 1K, this method efficiently cools very hot atoms and can sufficiently localize trapped atoms to produce near diffraction-limited atomic images.

arXiv:quant-ph/0507074•Journal of the Optical Society of America B•Jun 1, 2006•30 citations

Measurements of Motional Frequencies for Laser-cooled Ions in a Penning Trap

Hidetsuka Imajo, Shinji Urabe, Kazuhiro Hayasaka +1 more

The characteristics of laser-cooled Be+ ions stored in a Penning trap are reported. Be+ ions are cooled by a laser to approximately 300 mK and the cyclotron and axial frequencies of the cooled ions are measured by a laser fluorescence technique. In addition, ion resonances are observed when several kinds of ions are trapped with Be+ ions.

Journal of Modern Optics•Feb 1, 1992•16 citations

Laser Cooling of Trapped Ions

Wayne M. Itano, Jonas Bergquist, J. J. Bollinger +1 more

•Jan 1, 1991•5 citations

Direct Laser Cooling Al${}^{+}$ Ion Optical Clocks

Jie Zhang, Ke Deng, Jun Luo +1 more

The Al ion optical clock is a very promising optical frequency standard candidate due to its extremely small black-body radiation shift. It has been successfully demonstrated with the indirect cooled, quantum-logic-based spectroscopy technique. Its accuracy is limited by second-order Doppler shift, and its stability is limited by the number of ions that can be probed in quantum logic processing. We propose a direct laser cooling scheme of Al ion optical clocks where both the stability and accuracy of the clocks are greatly improved. In the proposed scheme, two Al traps are utilized. The first trap is used to trap a large number of Al ions to improve the stability of the clock laser, while the second trap is used to trap a single Al ion to provide the ultimate accuracy. Both traps are cooled with a continuous wave 167 nm laser. The expected clock laser stability can reach . For the second trap, in addition to 167 nm laser Doppler cooling, a second stage pulsed 234 nm two-photon cooling laser is utilized to further improve the accuracy of the clock laser. The total systematic uncertainty can be reduced to about . The proposed Al ion optical clock has the potential to become the most accurate and stable optical clock .

arXiv:1609.03667•Chinese Physics Letters•May 1, 2017•17 citations

Laser Cooling of Trapped Ions

Ferdinand Schmidt‐Kaler, Jürgen Eschner, R. Blatt +3 more

Springer eBooks•Jan 1, 2002•13 citations
Direct Laser Cooling Al+{}^{+}+ Ion Optical Clocks
The Al ion optical clock is a very promising optical frequency standard candidate due to its extremely small black-body radiation shift. It has been successfully demonstrated with the indirect cooled, quantum-logic-based spectroscopy technique. Its accuracy is limited by second-order Doppler shift, and its stability is limited by the number of ions that can be probed in quantum logic processing. We propose a direct laser cooling scheme of Al ion optical clocks where both the stability and accuracy of the clocks are greatly improved. In the proposed scheme, two Al traps are utilized. The first trap is used to trap a large number of Al ions to improve the stability of the clock laser, while the second trap is used to trap a single Al ion to provide the ultimate accuracy. Both traps are cooled with a continuous wave 167 nm laser. The expected clock laser stability can reach . For the second trap, in addition to 167 nm laser Doppler cooling, a second stage pulsed 234 nm two-photon cooling laser is utilized to further improve the accuracy of the clock laser. The total systematic uncertainty can be reduced to about . The proposed Al ion optical clock has the potential to become the most accurate and stable optical clock .