Beilstein Journal of Nanotechnology

Efficiency of electron cooling in cold-electron bolometers with traps

Dmitry A. Pimanov, Vladimir A Frost, Anton V Blagodatkin, Anna V. Gordeeva, A. L. Pankratov, L. S. Kuzmin

Published Sep 7, 2022• 11 citations
Publisher

Abstract

Electron on-chip cooling from the base temperature of 300 mK is very important for highly sensitive detectors operating in space due to problems of dilution fridges at low gravity. Electron cooling is also important for ground-based telescopes equipped with 3 He cryostats being able to function at any operating angle. This work is aimed at the investigation of electron cooling in the low-temperature range. New samples of cold-electron bolometers with traps and hybrid superconducting/ferromagnetic absorbers have shown a temperature reduction of the electrons in the refrigerator junctions from 300 to 82 mK, from 200 to 33 mK, and from 100 to 25 mK in the idle regime without optical power load. The electron temperature was determined by solving heat balance equations with account of the leakage current, sixth power of temperature in the whole temperature range, and the Andreev current using numerical methods and an automatic fit algorithm.

DOI
10.3762/bjnano.13.80

Related papers

Ultrasensitive Cold-Electron Bolometer

Ian Jasper Agulo

The Cold-Electron Bolometer (CEB) is an ultrasensitive device designed for the detection of cosmic microwave background radiation. The key to its sensitivity is the electron cooling of the absorber by the superconductor-insulator-normal metal (SIN) tunnel junction. At a voltage near and below the superconducting gap, the electrons in the absorber are cooled well below the phonon temperature of the normal metal. This translates to the enhanced sensitivity of the CEB. This thesis describes the work we have done on the optimization of electron cooling of the normal metal absorber, and our measurement of the sensitivity of the CEB. We have optimized the electron cooling of the absorber by SIN tunnel junctions. The best electron cooling was achieved when normal metal traps were added in proximity to the superconducting electrodes in addition to the advanced geometry of the superconducting electrodes. With these modifications, we have decreased the electron temperature by 198 mK. With just the advanced geometry, the electron temperature drop was 129 mK. With just a simple geometry, the drop in temperature was 56 mK.The noise equivalent power (NEP) of the CEB was also measured at 100 mK to be at the level of 10^-18 W/Hz^1/2 at 1 kHz. The NEP was obtained by measuring the noise of the CEB, and then dividing that by its power responsivity, dV/dP. The main limitation in our measurements was the noise component from the amplifier. Finally, we have made measurements on the temperature sensitivity of the SIN tunnel junctions. We have compared the sensitivity between single and ten SIN junctions in series and found that it increases proportionally to the number of junctions. The best temperature responsivity obtained for 10 junctions was approximately 15 μV/mK. Using such thermometer, we have been able to measure the temperature stability of the Oxford Instruments cryogenfree refrigerator to be plus/minus 250 μK for a period of 8 hours. The resolution of the thermometer was measured to be plus/minus100 μK, limited by the noise due to the amplifier. The current and future works are also discussed. These include: a CEB array designed to distribute the total power load, improving further the sensitivity; a one-thousand SIN tunnel junction series thermometer in order to realize and understand the fundamental limitation of such a device; a superconducting cold-electron bolometer (SCEB) for high background power loads; and different read-out systems including an on-chip quasiparticle amplifier (QPA).

•Aug 1, 2007•0 citations

Quantum Efficiency of Cold Electron Bolometer Optical Response

Michael A. Tarasov, Valerian S. Edelman, Andrey B. Ermakov +2 more

In this paper, we present the measurements of optical response dependence on power load of a Cold Electron Bolometer integrated in a twin slot antenna. These measurements are also compared to the models of the bolometer limit and the photon counter limit. The responsivity of 0.22*109V/W was measured at 0.22 pW radiation power from a black body at 3.5 K. According to our estimations, for optimized device the voltage responsivity at 100 mK electron temperature can approach S v = 1010V/W for power load below 0.1 pW and decreases down to 107V/W at 300 mK for 5 pW signal power in a sample with absorber volume of 5*10-20m3. In the case of low bath temperatures and high applied RF power the changes of tunneling current, dynamic resistance and voltage response are explained by non-thermal energy distribution of excited electrons. Distribution of excited electrons in such system at lower temperatures can be of non-Fermi type, hot electrons with energies of the order of 1 K tunnel from normal metal absorber to superconductor instead of relaxing down to thermal energy kTein absorber before tunneling. This effect can reduce quantum efficiency of the bolometer at 350 GHz from η = hf/kTph> 100 in ideal case down to single electron per absorbed photon ( η = 1) in the high power case. Methods of preserving high quantum efficiency are discussed.

IEEE Transactions on Terahertz Science and Technology•Jan 1, 2014•12 citations

Power load dependencies of cold electron bolometer optical response at 350 ghz

Michael A. Tarasov, Valeryan S. Edel'man, Andrey B. Ermakov +2 more

Cold electron bolometers integrated with twin-slot antennas have been designed and fabricated. Optical response was measured in 0.06-0.6 K temperature range using black body radiation source at temperature 2-15 K. The responsivity of 0.3109 V/W was measured at 2.7 K radiation temperature. The estimated ultimate dark responsivity at 100 mK can approach Sv=1010 V/W and reduces down to 1.1108 V/W at 300 mK for the sample with absorber volume of 510-20 m3. At high power load levels and low temperatures the changes of tunneling current, dynamic resistance and voltage response have been explained by non-thermal energy distribution of excited electrons. Distribution of excited electrons in such system is of none-Fermi type, electrons with energies of the order of 1 K tunnel from normal metal absorber to superconductor instead of relaxing down to thermal energy kTe. This effect can reduce quantum efficiency of bolometer from hf/kTph in ideal case down to single electron per signal quantum in the high power case.

•Jan 1, 2014•0 citations

Optimal Cold-Electron Bolometer with a Superconductor-Insulator-Normal Tunnel Junction and an Andreev Contact

L. S. Kuzmin

A novel concept of the optimal Cold-Electron Bolometer (CEB) with a Superconductor-Insulator-Normal (SIN) Tunnel Junction and Andreev SN contact has been proposed. This concept has been developed to improve noise properties of the CEB by increasing current responsivity for SQUID readout (in voltage-biased mode) in comparison with classical CEB concept comprising two SIN tunnel junctions. In this configuration the power of incoming signal is not split between two series junctions and the current response of a single junction is twice larger in comparison with double junction structure. The signal is concentrated from antenna to an absorber through capacitance of the tunnel junction from one side and Andreev contact from another side. HF matching is realized by resistance of a normal metal absorber that is independent on tunnel junction parameters. The volume of a normal metal is partly squeezed due to proximity effect of a superconducting electrode from the Andreev contact that also increases efficiency of the electron cooling. The concept is based on direct electron cooling of the absorber by SIN tunnel junction that serves as negative electrothermal feedback for the signal. Noise properties are considerably improved by decreasing the electron temperature. Ultimate performance of the CEB is determined by optical load converted to shot noise of the signal readout. The goal is to achieve noise-equivalent power (NEP) of the CEB with standard SQUID readout less than photon noise. Ultimate NEP better than photon noise can be achieved practically in wide range of power loads from 0.1 fW (SPICA) to 30 pW (OLIMPO, CLOVER, PILOT). Applicability of the CEB to post-Herschel space missions looks very promising.

•May 1, 2006•3 citations

Efficient electronic cooling by niobium-based superconducting tunnel junctions

Joel Hätinen, Alberto Ronzani, R. P. Loreto +15 more

Replacing the bulky cryoliquid-based cooling stages of cryoenabled instruments by chip-scale refrigeration is envisioned to disruptively reduce the system size similar to microprocessors did for computers. Electronic refrigerators based on superconducting tunnel junctions have been anticipated to provide a solution, but reaching the necessary above the 1-K operation temperature range has remained a goal out of reach for several decades. We show efficient electronic refrigeration by $\mathrm{Al}$-${\mathrm{Al}\mathrm{O}}_{x}$-$\mathrm{Nb}$ superconducting tunnel junctions starting from bath temperatures above 2 K. The junctions can deliver electronic cooling power up to approximately $\mathrm{mW}/{\mathrm{mm}}^{2}$, which enables us to demonstrate tunnel-current-driven electron temperature reduction from 2.4 K to below 1.6 K (34% relative cooling) against the phonon bath. Our work shows that the key material of integrated superconducting circuits---niobium---enables powerful cryogenic refrigerator technology. This result is a prerequisite for practical cryogenic chip-scale refrigerators and, at the same time, it introduces a new electrothermal tool for quantum heat-transport experiments.

arXiv:2403.08655•Physical Review Applied•Dec 13, 2024•10 citations

A Hot Spot Mixer Model for Superconducting Phonon-Cooled HEB Far Above the Quasiparticle Bandgap

Harald Merkel, P. Khosropanah, Pavel A. Yagoubov +1 more

Abstract — A hot spot mixer model for phonon cooled hot electron bolometers is set up to accurately determine the dependence of the bolometer resistance on bias and absorbed LO power. An one-dimensional power balance for the nonequilibrium electrons containing an electron heat conduction term along the film and a loss term due to phonon escape to the substrate is solved. In the device's operating region of interest the absorbed heating power is usually large enough to heat a part of the bolometer bridge above the critical temperature forming a normal conducting hot spot. In this model heating due to the LO is assumed to be uniform whereas bias heating takes place in the hot spot region only. Solving the nonlinear power balance for the hot spot length allows to predict current-voltage characteristics, required heating powers and regions of optimal operation. Applying a small signal model in a given operating point yields an estimate for the intrinsic conversion gain. I. LARGE SIGNAL MODEL Existing device models for hot electron bolometers [1,2] treat the bolometer as a lumped element. It is assigned an effective temperature for the phonons and another for the electrons at a given bath temperature. In terms of heating bias power and RF power are equivalent and exchangeable. From this a method [3,4] to calculate the absorbed RF power is derived. This method is referred to as "isotherm " method: Operating points with identical device resistance must have identical temperatures since R(To„,,(,,, ) is a single valued monotonous function. Identical temperature implies identical power losses and identical 592

Softwaretechnik-Trends•Mar 1, 1999•5 citations
Electron on-chip cooling from the base temperature of 300 mK is very important for highly sensitive detectors operating in space due to problems of dilution fridges at low gravity. Electron cooling is also important for ground-based telescopes equipped with 3 He cryostats being able to function at any operating angle. This work is aimed at the investigation of electron cooling in the low-temperature range. New samples of cold-electron bolometers with traps and hybrid superconducting/ferromagnetic absorbers have shown a temperature reduction of the electrons in the refrigerator junctions from 300 to 82 mK, from 200 to 33 mK, and from 100 to 25 mK in the idle regime without optical power load. The electron temperature was determined by solving heat balance equations with account of the leakage current, sixth power of temperature in the whole temperature range, and the Andreev current using numerical methods and an automatic fit algorithm.
The Cold-Electron Bolometer (CEB) is an ultrasensitive device designed for the detection of cosmic microwave background radiation. The key to its sensitivity is the electron cooling of the absorber by the superconductor-insulator-normal metal (SIN) tunnel junction. At a voltage near and below the superconducting gap, the electrons in the absorber are cooled well below the phonon temperature of the normal metal. This translates to the enhanced sensitivity of the CEB. This thesis describes the work we have done on the optimization of electron cooling of the normal metal absorber, and our measurement of the sensitivity of the CEB. We have optimized the electron cooling of the absorber by SIN tunnel junctions. The best electron cooling was achieved when normal metal traps were added in proximity to the superconducting electrodes in addition to the advanced geometry of the superconducting electrodes. With these modifications, we have decreased the electron temperature by 198 mK. With just the advanced geometry, the electron temperature drop was 129 mK. With just a simple geometry, the drop in temperature was 56 mK.The noise equivalent power (NEP) of the CEB was also measured at 100 mK to be at the level of 10^-18 W/Hz^1/2 at 1 kHz. The NEP was obtained by measuring the noise of the CEB, and then dividing that by its power responsivity, dV/dP. The main limitation in our measurements was the noise component from the amplifier. Finally, we have made measurements on the temperature sensitivity of the SIN tunnel junctions. We have compared the sensitivity between single and ten SIN junctions in series and found that it increases proportionally to the number of junctions. The best temperature responsivity obtained for 10 junctions was approximately 15 μV/mK. Using such thermometer, we have been able to measure the temperature stability of the Oxford Instruments cryogenfree refrigerator to be plus/minus 250 μK for a period of 8 hours. The resolution of the thermometer was measured to be plus/minus100 μK, limited by the noise due to the amplifier. The current and future works are also discussed. These include: a CEB array designed to distribute the total power load, improving further the sensitivity; a one-thousand SIN tunnel junction series thermometer in order to realize and understand the fundamental limitation of such a device; a superconducting cold-electron bolometer (SCEB) for high background power loads; and different read-out systems including an on-chip quasiparticle amplifier (QPA).
In this paper, we present the measurements of optical response dependence on power load of a Cold Electron Bolometer integrated in a twin slot antenna. These measurements are also compared to the models of the bolometer limit and the photon counter limit. The responsivity of 0.22*109V/W was measured at 0.22 pW radiation power from a black body at 3.5 K. According to our estimations, for optimized device the voltage responsivity at 100 mK electron temperature can approach S v = 1010V/W for power load below 0.1 pW and decreases down to 107V/W at 300 mK for 5 pW signal power in a sample with absorber volume of 5*10-20m3. In the case of low bath temperatures and high applied RF power the changes of tunneling current, dynamic resistance and voltage response are explained by non-thermal energy distribution of excited electrons. Distribution of excited electrons in such system at lower temperatures can be of non-Fermi type, hot electrons with energies of the order of 1 K tunnel from normal metal absorber to superconductor instead of relaxing down to thermal energy kTein absorber before tunneling. This effect can reduce quantum efficiency of the bolometer at 350 GHz from η = hf/kTph> 100 in ideal case down to single electron per absorbed photon ( η = 1) in the high power case. Methods of preserving high quantum efficiency are discussed.
Cold electron bolometers integrated with twin-slot antennas have been designed and fabricated. Optical response was measured in 0.06-0.6 K temperature range using black body radiation source at temperature 2-15 K. The responsivity of 0.3109 V/W was measured at 2.7 K radiation temperature. The estimated ultimate dark responsivity at 100 mK can approach Sv=1010 V/W and reduces down to 1.1108 V/W at 300 mK for the sample with absorber volume of 510-20 m3. At high power load levels and low temperatures the changes of tunneling current, dynamic resistance and voltage response have been explained by non-thermal energy distribution of excited electrons. Distribution of excited electrons in such system is of none-Fermi type, electrons with energies of the order of 1 K tunnel from normal metal absorber to superconductor instead of relaxing down to thermal energy kTe. This effect can reduce quantum efficiency of bolometer from hf/kTph in ideal case down to single electron per signal quantum in the high power case.
A novel concept of the optimal Cold-Electron Bolometer (CEB) with a Superconductor-Insulator-Normal (SIN) Tunnel Junction and Andreev SN contact has been proposed. This concept has been developed to improve noise properties of the CEB by increasing current responsivity for SQUID readout (in voltage-biased mode) in comparison with classical CEB concept comprising two SIN tunnel junctions. In this configuration the power of incoming signal is not split between two series junctions and the current response of a single junction is twice larger in comparison with double junction structure. The signal is concentrated from antenna to an absorber through capacitance of the tunnel junction from one side and Andreev contact from another side. HF matching is realized by resistance of a normal metal absorber that is independent on tunnel junction parameters. The volume of a normal metal is partly squeezed due to proximity effect of a superconducting electrode from the Andreev contact that also increases efficiency of the electron cooling. The concept is based on direct electron cooling of the absorber by SIN tunnel junction that serves as negative electrothermal feedback for the signal. Noise properties are considerably improved by decreasing the electron temperature. Ultimate performance of the CEB is determined by optical load converted to shot noise of the signal readout. The goal is to achieve noise-equivalent power (NEP) of the CEB with standard SQUID readout less than photon noise. Ultimate NEP better than photon noise can be achieved practically in wide range of power loads from 0.1 fW (SPICA) to 30 pW (OLIMPO, CLOVER, PILOT). Applicability of the CEB to post-Herschel space missions looks very promising.
Replacing the bulky cryoliquid-based cooling stages of cryoenabled instruments by chip-scale refrigeration is envisioned to disruptively reduce the system size similar to microprocessors did for computers. Electronic refrigerators based on superconducting tunnel junctions have been anticipated to provide a solution, but reaching the necessary above the 1-K operation temperature range has remained a goal out of reach for several decades. We show efficient electronic refrigeration by Al\mathrm{Al}Al-AlOx{\mathrm{Al}\mathrm{O}}_{x}AlOx​-Nb\mathrm{Nb}Nb superconducting tunnel junctions starting from bath temperatures above 2 K. The junctions can deliver electronic cooling power up to approximately mW/mm2\mathrm{mW}/{\mathrm{mm}}^{2}mW/mm2, which enables us to demonstrate tunnel-current-driven electron temperature reduction from 2.4 K to below 1.6 K (34% relative cooling) against the phonon bath. Our work shows that the key material of integrated superconducting circuits---niobium---enables powerful cryogenic refrigerator technology. This result is a prerequisite for practical cryogenic chip-scale refrigerators and, at the same time, it introduces a new electrothermal tool for quantum heat-transport experiments.
Abstract — A hot spot mixer model for phonon cooled hot electron bolometers is set up to accurately determine the dependence of the bolometer resistance on bias and absorbed LO power. An one-dimensional power balance for the nonequilibrium electrons containing an electron heat conduction term along the film and a loss term due to phonon escape to the substrate is solved. In the device's operating region of interest the absorbed heating power is usually large enough to heat a part of the bolometer bridge above the critical temperature forming a normal conducting hot spot. In this model heating due to the LO is assumed to be uniform whereas bias heating takes place in the hot spot region only. Solving the nonlinear power balance for the hot spot length allows to predict current-voltage characteristics, required heating powers and regions of optimal operation. Applying a small signal model in a given operating point yields an estimate for the intrinsic conversion gain. I. LARGE SIGNAL MODEL Existing device models for hot electron bolometers [1,2] treat the bolometer as a lumped element. It is assigned an effective temperature for the phonons and another for the electrons at a given bath temperature. In terms of heating bias power and RF power are equivalent and exchangeable. From this a method [3,4] to calculate the absorbed RF power is derived. This method is referred to as "isotherm " method: Operating points with identical device resistance must have identical temperatures since R(To„,,(,,, ) is a single valued monotonous function. Identical temperature implies identical power losses and identical 592