A quantum gas microscope plays an important role in cold-atom experiments, which provides a high-resolution imaging of the spatial distributions of cold atoms. Here we design, build and calibrate an integrated microscope for quantum gases with all the optical components fixed outside the vacuum chamber. It provides large numerical aperture (NA) of 0.75, as well as good optical access from side for atom loading in cold-atom experiments due to long working distance (7 mm fused silica+6 mm vacuum) of the microscope objective. We make a special design of the vacuum viewport with a T-shape window, to suppress the window flatness distortion introduced by the metal-glass binding process, and protect the high-resolution imaging from distortions due to unflattened window. The achieved Strehl ratio is 0.9204 using scanning-near-field microscopy (SNOM) fiber coupling incoherent light as point light source.
A quantum gas microscope plays an important role in cold-atom experiments, which provides a high-resolution imaging of the spatial distributions of cold atoms. Here we design, build and calibrate an integrated microscope for quantum gases with all the optical components fixed outside the vacuum chamber. It provides large numerical aperture (NA) of 0.75, as well as good optical access from side for atom loading in cold-atom experiments due to long working distance (7 mm fused silica+6 mm vacuum) of the microscope objective. We make a special design of the vacuum viewport with a T-shape window, to suppress the window flatness distortion introduced by the metal-glass binding process, and protect the high-resolution imaging from distortions due to unflattened window. The achieved Strehl ratio is 0.9204 using scanning-near-field microscopy (SNOM) fiber coupling incoherent light as point light source.
In cold atom experiments, high resolution imaging systems have been used to extract in-situ density information when studying quantum gases, which is one of the hot topics in this field. Such a system is usually called “quantum-gas microscope”. In order to achieve a long working distance and large magnification, high resolution imaging of cold atoms through a vacuum window usually requires a long distance between the atoms and the camera. However, due to space limitation caused by a large number of nearby optical elements, it may be difficult to realize a long imaging system, which is a common case in cold atom experiments. Herein we present an imaging system that can achieve a short distance between the atoms and the image plane with diffraction-limited 1 μm resolution and 50 magnification. The telephoto lens design is adopted to reduce the back focal length and enhance the pointing stability of the imaging lens. The system is optimized at an operating wavelength of 767 nm and corrects aberrations induced by a 5-mm-thick silica vacuum window. At a working distance of 32 mm, a diffraction-limited field of view of 408 μm is obtained. The simulation result shows that by changing the air space between lenses, our design operates across a wide range of window thicknesses (0–15 mm), which makes it robust enough to be used in typical laboratories. This compact imaging system is made from commercial on-shelf Φ2 in (1 in = 2.54 cm) singlets and consists of two components: a microscope objective with a numerical aperture of 0.47 and a telephoto objective with a long effective focal length of 1826 mm. Both are infinitely corrected, allowing the distance between them to be adjusted to insert optical elements for irradiating atoms with laser beams of different wavelengths without affecting the imaging resolution. Taking the manufacturing and assembling tolerances into consideration, the Monte Carlo analyses show that more than 95% of the random samples are diffraction-limited within the field of view. This high success rate ensures that these two objectives can be achieved easily in the experiment. Combined with its performance with other wavelengths (470–1064 nm), this imaging system can be used for imaging different atom species, such as sodium, lithium, and cesium.
We present a high resolution objective lens made entirely from catalog singlets that has a numerical aperture of 0.36. It corrects for aberrations introduced by a glass window and has a long working distance of 35 mm, making it suitable for imaging objects within a vacuum system. This offers simple high resolution imaging for many in the quantum gas community. The objective achieves a resolution of 1.3 μm at the design wavelength of 780 nm, and a diffraction-limited field of view of 360 μm when imaging through a 5 mm thick window. Images of a resolution target and a pinhole show quantitative agreement with the simulated lens performance. The objective is suitable for diffraction-limited monochromatic imaging on the D2 line of all the alkalis by changing only the aperture diameter, retaining numerical apertures above 0.32. The design corrects for window thicknesses of up to 15 mm if the singlet spacings are modified.
This thesis describes the methods used to achieve single-atom and single-site resolved fluorescence imaging of a quantum gas of fermionic atoms held in an optical lattice. This kind of quantum gas microscopy has been previously applied to bosonic atoms in two experiments, and has allowed for extensive studies of many-body quantum systems. Here we detail methods to extend the techniques of quantum gas microscopy to fermionic species of atoms, opening the door to quantum simulation of electronic models of condensed matter physics. We prepare quantum degenerate gases of fermionic 40K through sympathetic cooling with a gas of \Rb. The gas prepared is trapped less than 1 mm away from a thin vacuum window, an experimental geometry which permits interrogation with a large Numerical Aperture microscope objective. The cloud is loaded into a 527 nm-period cubic optical lattice, ideal for quantum simulation of many-body models of fermionic particles such as the Hubbard model. The optical lattice is designed to allow for potential depths up to V/kB = 250 microKelvin, sufficient to strongly confine 40K atoms into individual lattice sites. EIT cooling --- a technique previously demonstrated in ion-trapping experiments --- is used to cool the fermionic atoms deeply towards the ground motional state of the lattice wells. We collect the photons scattered during continuous application of EIT cooling, while atoms are kept pinned in the lattice for many seconds. We strongly suppress all other sources of light with the use of a modulated cooling scheme and a spinning chopper wheel. Collecting the scattered light produced during 2 s of EIT cooling allows us to resolve single atoms in a fluorescence image. We demonstrate that the high resolution of our imaging apparatus also permits atom positions to be precisely identified on the length scale of the optical lattice. Thus we demonstrate the realisation of a quantum gas microscope for fermionic atoms, allowing for precise investigation of the ground states and dynamics of correlated quantum states of fermionic particles.
This thesis details the complete upgrade and renovation of an existing experimental platform into a high-resolution quantum gas microscope for ultracold 87Rb atoms. Quantum gas microscopes enable site-resolved imaging, providing unprecedented access to quantum statistical effects and many-body phenomena. While such instruments are often employed to study physics in optical lattices, we have innovatively adapted our apparatus to investigate bulk system behavior. A major part of this project involved upgrading the scientific apparatus and retrofitting the previous system. We introduced new optical components, including a high-NA objective, and improved the vacuum system for better optical access. Extensive lab renovations, from upgrading the optical table to reorganizing the laser and imaging setups, were carried out to enhance mechanical and thermal stability. Rigorous optical benchmarking confirmed that the objective achieves diffractionlimited imaging, which is critical for resolving single atoms. This capability allowed us to detect density fluctuations at the scale of the thermal de Broglie wavelength in a quasi-two-dimensional gas of 87Rb atoms. In an experiment resembling Hanbury Brown and Twiss interferometry, we measured a 30% enhancement in the second-order correlation function in situ, demonstrating strong bosonic bunching. This outcome underscores the microscope’s precision and the importance of high-resolution imaging in capturing subtle quantum statistical effects. The successful realization of this apparatus demonstrates the utility of quantum gas microscopes in probing bulk systems. With this new platform in place, future studies can explore critical phenomena, many-body correlations, matter-wave emission, and quantum simulations with cold atoms.
We present the design and assembly of a cavity microscope for quantum simulations with ultracold atoms. The system integrates a high-finesse optical cavity with a pair of high-numerical aperture lenses sharing a common optical axis, enabling simultaneous operation with light close-to-atomic resonance. The system keeps the advantages of a rigid, single-block structure holding the lenses and cavity together, and improves over existing designs by using most of the solid angle left free by the cavity mode for imaging and atomic manipulation purposes. The cavity has a length of 19.786 mm, a finesse of 2.35 × 10 4 and operates 214 µm away from the concentric limit, deep in the strong coupling regime. The two lenses offer a numerical aperture of 0.52 each and maximal optical access in all directions transverse to the cavity axis, compatible with applications in quantum-gas microscopes, micro-tweezer arrays or few-fermions systems, as well as future cavity-assisted quantum simulation protocols demanding sub-cavity-mode control of the atom-cavity coupling.
In this thesis, I present single-site detection of neutral atoms stored in a three-dimensional optical lattice using a numerical aperture objective lens (NAdesign = 0.92). The combination of high-resolution imaging with state-dependent trapping along two-direction of the lattice opens up the path towards quantum simulations via quantum walks. Suppressing the interactions of a quantum system with the environment is essential for all quantum simulation experiments. It demands a precise control of both the external magnetic (stray) fields and the polarization properties of laser beams inside the vacuum chamber. I designed a metal shielding to reduce magnetic field fluctuations and designed, assembled and characterized a novel ultra-high vacuum glass cell. The glass cell consists of special glass material and exhibits an ultra-low birefringence Δn of a few times 10^-8 to highly suppress polarization disturbances originating from stress birefringence in vacuum windows. Furthermore, anti-reflection coatings avoid reflections on all window surfaces. The cell hosts the assembled vacuum-compatible objective, that exhibits a diffraction limited resolution of up to 453 nm and allows to optically resolve the spacing of the optical lattice. Fluorescence images of single trapped atoms are used to characterize the imaging system. The filling, orientation and geometry of the optical lattice is precisely reconstructed using positions of atoms that can be determined from fluorescence images. Furthermore, I present a scheme to realize state-dependent transport and discuss its robustness against experimental imperfections in a technical implementation. This transport scheme enable the realization of discrete-time quantum walks with neutral atoms in two dimensions. These quantum walks pave the way towards the simulation of artificial magnetic fields and topologically protected edge states.