Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

MULTIMODE SQUEEZING PROPERTIES OF A CONFOCAL OPO: BEYOND THE THIN CRYSTAL APPROXIMATION

Lopez, Laurent, Sylvain Gigan, Nicolas Treps, Agnès Maître, Claude Fabre, Gatti, Alessandra

Published Jan 1, 2005• 0 citations
OpenAlex

Abstract

Up to now, transverse quantum effects (usually labelled as "quantum imaging" effects) which are generated by nonlinear devices inserted in resonant optical cavities have been calculated using the "thin crystal approximation", i.e. taking into account the effect of diffraction only inside the empty part of the cavity, and neglecting its effect in the nonlinear propagation inside the nonlinear crystal. We introduce in the present paper a theoretical method which is not restricted by this approximation. It allows us in particular to treat configurations closer to the actual experimental ones, where the crystal length is comparable to the Rayleigh length of the cavity mode. We use this method in the case of the confocal OPO, where the thin crystal approximation predicts perfect squeezing on any area of the transverse plane, whatever its size and shape. We find that there exists in this case a "coherence length" which gives the minimum size of a detector on which perfect squeezing can be observed, and which gives therefore a limit to the improvement of optical resolution that can be obtained using such devices.

Related papers

Multimode squeezing properties of a confocal optical parametric oscillator: Beyond the thin-crystal approximation

L. Lopez, Sylvain Gigan, Nicolas Treps +3 more

Up to now, transverse quantum effects (usually labeled as ``quantum imaging'' effects) which are generated by nonlinear devices inserted in resonant optical cavities have been calculated using the ``thin-crystal approximation,'' i.e., taking into account the effect of diffraction only inside the empty part of the cavity, and neglecting its effect in the nonlinear propagation inside the nonlinear crystal. We introduce in the present paper a theoretical method which is not restricted by this approximation. It allows us in particular to treat configurations closer to the actual experimental ones, where the crystal length is comparable to the Rayleigh length of the cavity mode. We use this method in the case of the confocal optical parametric oscillator, where the thin-crystal approximation predicts perfect squeezing on any area of the transverse plane, whatever its size and shape. We find that there exists in this case a ``coherence length'' which gives the minimum size of a detector on which perfect squeezing can be observed, and which gives therefore a limit to the improvement of optical resolution that can be obtained using such devices.

arXiv:quant-ph/0503055•Physical Review A•Jul 8, 2005•12 citations

Spatial squeezing and super-resolution in optical imaging

Mikhail I. Kolobov, Claude Fabre

Summary form only given. To achieve super-resolution one must take into account a priori information about localization of the object. Such an a priori information exists in the case of an object of finite size. Its Fourier transform located in the focal plane of the lens is an entire analytic function, and analytic continuation of the object spectrum outside the spatial-frequency band allows for unlimited resolution. However such a super-resolution is extremely sensitive to the noise in the detected image. The ultimate limit of super-resolution is determined by the quantum fluctuations of light in the detection plane. We present the quantum theory of super-resolution for a one-dimensional coherent optical imaging scheme and discuss possibilities of improving the resolution limit by using multimode squeezed light. For quantum-mechanical description of this scheme we take into account the vacuum fluctuations of the electromagnetic field in the input plane outside the object. Interference of these vacuum fluctuations with the field amplitude of the object in the detection plane is the origin of the standard quantum limit or shot noise of photodetection in the image. To go beyond this limit we suggest to illuminate the object with multimode squeezed light having the spot size much larger than the object area. Then the vacuum fluctuations outside the object can be effectively suppressed resulting in sub-shot-noise detection of the image.

Conference on Lasers and Electro-Optics•Aug 29, 2005•0 citations

Quantum imaging with continuous variables

Sylvain Gigan, V. Delaubert, M. Martinelli +3 more

The visibility and quality of optical images is ultimately limited not by diffraction but by the quantum noise affecting each pixel of a detector. Multimode non-classical states of light, characterized by spatial quantum correlation or local reduced quantum noise, permit in principle to go beyond the standard quantum limit and therefore to improve transverse optical resolution. It has been predicted that Optical Parametric Oscillators (OPO) operating simultaneously on many transverse modes are good candidates for generating multimode non-classical states of light. We perform an experiment showing that a c.w. confocal OPO above threshold emits such states. Below threshold, the OPO is turned to a multimode optical parametric amplifier.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Feb 3, 2004•0 citations

Multimode quantum properties of a self-imaging optical parametric oscillator: Squeezed vacuum and Einstein-Podolsky-Rosen-beams generation

L. Lopez, Bénoît Chalopin, Arnaud Rivière De La Souchère +3 more

We investigate the spatial quantum properties of the light emitted by a perfectly spatially degenerate optical parametric oscillator (self-imaging optical parametric oscillator). We show that this device produces local squeezing for areas bigger than a coherence area that depends on the crystal length and pump width. Furthermore, it generates local EPR beams in the far field. We show, calculating the eigenmodes of the system, that it is highly multimode for realistic experimental parameters.

arXiv:0812.4735•Physical Review A•Oct 16, 2009•25 citations

Quantum Image Generation by c.w. Optical Parametric Amplification

L. Lopez, Nicolas Treps, Claude Fabre +1 more

In this paper, experimental evidence of cw amplification of images in the quantum regime, using a phase sensitive optical parametric amplification operating inside transverse degenerate cavities. Injecting various images (mismatched Gaussian modes and double slits of different orientations) at the input of the device, showed that the output image was amplitude squeezed by 30% in the regime of deamplification of a type II frequency-degenerate OPO operating below threshold in a semi-confocal cavity, when the polarization of the input image is at 45deg from the crystal axes. The authors showed also that, in the regime of amplification, the two polarization components along the signal and idler axes had quantum correlated intensity fluctuations (intensity difference fluctuations measured at 30% below the standard quantum noise level).

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 1, 2007•0 citations

Quantum Imaging: Fundamentals And Promises

Mikhail I. Kolobov

Quantum imaging can be defined as an area of quantum optics that investigates the ultimate performance limits of optical imaging allowed by the quantum nature of light. Quantum Imaging techniques possess a high potential for improving the performance in recording, storage, and readout of optical images beyond the limits set by the standard quantum level of fluctuations known as the shot noise. This talk aims at giving an overview of the fundamentals of Quantum Imaging as well as its most important directions. We shall discuss generation of the spatially multimode squeezed states of light be means of a travelling-wave optical parametric amplifier. We shall demonstrate that this kind of light allows us to reduce the spatial fluctuations of the photocurrent in a properly chosen homodyne detection scheme with a highly efficient CCD camera. It will be shown that using the amplified quadrature of the light wave in a travelling-wave optical parametric amplifier, one can perform noiseless amplification of optical images. We shall provide recent experimental results demonstrating a single-shot noiseless image amplification by a pulsed optical parametric amplifier. One of important experimental achievements of Quantum Imaging, coined in the literature as quantum laser pointer, is a precise measurement of position and transverse displacement of a laser beam with resolution beyond the limit imposed by the shot noise. We shall describe briefly the idea of the experiment in which the transverse displacement of a laser beam was measured with resolution of the order of Angstrom. The problem of precise measurement of transverse displacement of a light beam brings us to a more general question about the quantum limits of optical resolution. The classical resolution criterion, derived in the nineteen century by Abbe and Rayleigh, states that the resolution of an optical instrument is limited by diffraction and is related to the wavelength of the light used in the imaging scheme. However, it was for a long time recognised in the literature that in some cases when one has some a priori information about the object, one can improve the resolution beyond the Rayleigh limit using the so-called super-resolution techniques. As a final topic in this talk, we shall discuss the quantum limits of optical super-resolution. In particular, we shall formulate the standard quantum limit of super-resolution and demonstrate how one can go beyond this limit using specially designed multimode squeezed light.

Qatar Foundation Annual Research Forum Volume 2013 Issue 1•Jan 1, 2013•0 citations
Up to now, transverse quantum effects (usually labelled as "quantum imaging" effects) which are generated by nonlinear devices inserted in resonant optical cavities have been calculated using the "thin crystal approximation", i.e. taking into account the effect of diffraction only inside the empty part of the cavity, and neglecting its effect in the nonlinear propagation inside the nonlinear crystal. We introduce in the present paper a theoretical method which is not restricted by this approximation. It allows us in particular to treat configurations closer to the actual experimental ones, where the crystal length is comparable to the Rayleigh length of the cavity mode. We use this method in the case of the confocal OPO, where the thin crystal approximation predicts perfect squeezing on any area of the transverse plane, whatever its size and shape. We find that there exists in this case a "coherence length" which gives the minimum size of a detector on which perfect squeezing can be observed, and which gives therefore a limit to the improvement of optical resolution that can be obtained using such devices.
Up to now, transverse quantum effects (usually labeled as ``quantum imaging'' effects) which are generated by nonlinear devices inserted in resonant optical cavities have been calculated using the ``thin-crystal approximation,'' i.e., taking into account the effect of diffraction only inside the empty part of the cavity, and neglecting its effect in the nonlinear propagation inside the nonlinear crystal. We introduce in the present paper a theoretical method which is not restricted by this approximation. It allows us in particular to treat configurations closer to the actual experimental ones, where the crystal length is comparable to the Rayleigh length of the cavity mode. We use this method in the case of the confocal optical parametric oscillator, where the thin-crystal approximation predicts perfect squeezing on any area of the transverse plane, whatever its size and shape. We find that there exists in this case a ``coherence length'' which gives the minimum size of a detector on which perfect squeezing can be observed, and which gives therefore a limit to the improvement of optical resolution that can be obtained using such devices.
Summary form only given. To achieve super-resolution one must take into account a priori information about localization of the object. Such an a priori information exists in the case of an object of finite size. Its Fourier transform located in the focal plane of the lens is an entire analytic function, and analytic continuation of the object spectrum outside the spatial-frequency band allows for unlimited resolution. However such a super-resolution is extremely sensitive to the noise in the detected image. The ultimate limit of super-resolution is determined by the quantum fluctuations of light in the detection plane. We present the quantum theory of super-resolution for a one-dimensional coherent optical imaging scheme and discuss possibilities of improving the resolution limit by using multimode squeezed light. For quantum-mechanical description of this scheme we take into account the vacuum fluctuations of the electromagnetic field in the input plane outside the object. Interference of these vacuum fluctuations with the field amplitude of the object in the detection plane is the origin of the standard quantum limit or shot noise of photodetection in the image. To go beyond this limit we suggest to illuminate the object with multimode squeezed light having the spot size much larger than the object area. Then the vacuum fluctuations outside the object can be effectively suppressed resulting in sub-shot-noise detection of the image.
The visibility and quality of optical images is ultimately limited not by diffraction but by the quantum noise affecting each pixel of a detector. Multimode non-classical states of light, characterized by spatial quantum correlation or local reduced quantum noise, permit in principle to go beyond the standard quantum limit and therefore to improve transverse optical resolution. It has been predicted that Optical Parametric Oscillators (OPO) operating simultaneously on many transverse modes are good candidates for generating multimode non-classical states of light. We perform an experiment showing that a c.w. confocal OPO above threshold emits such states. Below threshold, the OPO is turned to a multimode optical parametric amplifier.
In this paper, experimental evidence of cw amplification of images in the quantum regime, using a phase sensitive optical parametric amplification operating inside transverse degenerate cavities. Injecting various images (mismatched Gaussian modes and double slits of different orientations) at the input of the device, showed that the output image was amplitude squeezed by 30% in the regime of deamplification of a type II frequency-degenerate OPO operating below threshold in a semi-confocal cavity, when the polarization of the input image is at 45deg from the crystal axes. The authors showed also that, in the regime of amplification, the two polarization components along the signal and idler axes had quantum correlated intensity fluctuations (intensity difference fluctuations measured at 30% below the standard quantum noise level).
Quantum imaging can be defined as an area of quantum optics that investigates the ultimate performance limits of optical imaging allowed by the quantum nature of light. Quantum Imaging techniques possess a high potential for improving the performance in recording, storage, and readout of optical images beyond the limits set by the standard quantum level of fluctuations known as the shot noise. This talk aims at giving an overview of the fundamentals of Quantum Imaging as well as its most important directions. We shall discuss generation of the spatially multimode squeezed states of light be means of a travelling-wave optical parametric amplifier. We shall demonstrate that this kind of light allows us to reduce the spatial fluctuations of the photocurrent in a properly chosen homodyne detection scheme with a highly efficient CCD camera. It will be shown that using the amplified quadrature of the light wave in a travelling-wave optical parametric amplifier, one can perform noiseless amplification of optical images. We shall provide recent experimental results demonstrating a single-shot noiseless image amplification by a pulsed optical parametric amplifier. One of important experimental achievements of Quantum Imaging, coined in the literature as quantum laser pointer, is a precise measurement of position and transverse displacement of a laser beam with resolution beyond the limit imposed by the shot noise. We shall describe briefly the idea of the experiment in which the transverse displacement of a laser beam was measured with resolution of the order of Angstrom. The problem of precise measurement of transverse displacement of a light beam brings us to a more general question about the quantum limits of optical resolution. The classical resolution criterion, derived in the nineteen century by Abbe and Rayleigh, states that the resolution of an optical instrument is limited by diffraction and is related to the wavelength of the light used in the imaging scheme. However, it was for a long time recognised in the literature that in some cases when one has some a priori information about the object, one can improve the resolution beyond the Rayleigh limit using the so-called super-resolution techniques. As a final topic in this talk, we shall discuss the quantum limits of optical super-resolution. In particular, we shall formulate the standard quantum limit of super-resolution and demonstrate how one can go beyond this limit using specially designed multimode squeezed light.