Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Quantum spatial correlations in the photon-counting regime

Jean-Luc Blanchet, Éric Lantz, Luca Furfaro, F. Devaux

Published Sep 29, 2008• 0 citations
OpenAlex

Related papers

Photon Correlation of Correlated Photons

John Rarity, P. R. Tapster

Springer eBooks•Jan 1, 1997•0 citations

Image-Plane Detection of Spatially Entangled Photon Pairs with a CMOS Camera

David McFadden, Rainer Heintzmann

Spatially entangled photon pairs (biphotons) generated by spontaneous parametric down-conversion offer unique opportunities for quantum imaging, but image-plane biphoton correlations are difficult to observe with camera-based detectors. Previous camera-based biphoton imaging experiments have relied on photon-counting detection, which necessitates operation deep in the photon-sparse regime and requires extremely low dark rates. Here, we demonstrate the detection of spatial biphoton joint probability distributions in both the image plane and the pupil plane (also termed "near-field plane" and "far-field plane" respectively) using a conventional scientific CMOS camera operated in linear mode. We work at mesoscopic intensity levels, corresponding to a photon flux approximately four orders of magnitude higher than typical photon-counting approaches. From the measured image- and pupil plane correlations, we observe position and momentum correlations consistent with an EPR-type entanglement witness. A tailored correlation analysis suited for image plane imaging suppresses detector artifacts and intensity fluctuations, enabling acquisition with significantly fewer frames. Our results demonstrate that spatially entangled-light imaging can be performed efficiently with standard imaging hardware, extending quantum imaging techniques beyond the photon-counting regime.

quant-pharXiv:2512.24878•Jan 1, 2026•0 citations

Photon Counting and Field Correlations

Roy J. Glauber

•Jan 1, 1966•12 citations

Resolution and Contrast Enhancement of Correlated Imaging in Photon Counting Regime

Feng Wen, Xun Zhang, Chenzhi Yuan +4 more

We theoretically discuss the four-photon spatial correlation property under different detection schemes. Compared with the two- and three-photon spatial correlation of thermal light source, we found that the enhancement in the visibility and the contrast when the fourth-order spatial correlation function is measured with quadruple coincidence measurement in the single photon counting regime. The resolution, however, is not changed when we scan three of four detectors with identical speed and direction. But if we scan two of three detectors in opposite directions and same speed, simultaneously, other two in identical direction and speed of one detector is twice of that of the other, we can see that both the contrast and resolution are improved significantly. We also show that the conclusion can be applied to the Nth-order ghost imaging.

Journal of the Physical Society of Japan•Sep 24, 2014•4 citations

Photon-photon correlation: milestones in quantum optics

Alain Aspect

•Jan 6, 2008•0 citations

Fourth-Order Spatial Correlation of Thermal Light

Feng Wen, Xun Zhang, Xinxin Xue +3 more

We investigate the fourth-order spatial correlation properties of pseudo-thermal light in the photon counting regime, and apply the Klyshko advanced-wave picture to describe the process of four-photon coincidence counting measurement. We deduce the theory of a proof-of-principle four-photon coincidence counting configuration, and find that if the four randomly radiated photons come from the same radiation area and are indistinguishable in principle, the fourth-order correlation of them is 24 times larger than that when four photons come from different radiation areas. In addition, we also show that the higher-order spatial correlation function can be decomposed into multiple lower-order correlation functions, and the contrast and visibility of low-order correlation peaks are less than those of higher orders, while the resolutions all are identical. This study may be useful for better understanding the four-photon interference and multi-channel correlation imaging.

Chinese Physics Letters•Nov 1, 2014•4 citations
Spatially entangled photon pairs (biphotons) generated by spontaneous parametric down-conversion offer unique opportunities for quantum imaging, but image-plane biphoton correlations are difficult to observe with camera-based detectors. Previous camera-based biphoton imaging experiments have relied on photon-counting detection, which necessitates operation deep in the photon-sparse regime and requires extremely low dark rates. Here, we demonstrate the detection of spatial biphoton joint probability distributions in both the image plane and the pupil plane (also termed "near-field plane" and "far-field plane" respectively) using a conventional scientific CMOS camera operated in linear mode. We work at mesoscopic intensity levels, corresponding to a photon flux approximately four orders of magnitude higher than typical photon-counting approaches. From the measured image- and pupil plane correlations, we observe position and momentum correlations consistent with an EPR-type entanglement witness. A tailored correlation analysis suited for image plane imaging suppresses detector artifacts and intensity fluctuations, enabling acquisition with significantly fewer frames. Our results demonstrate that spatially entangled-light imaging can be performed efficiently with standard imaging hardware, extending quantum imaging techniques beyond the photon-counting regime.
We theoretically discuss the four-photon spatial correlation property under different detection schemes. Compared with the two- and three-photon spatial correlation of thermal light source, we found that the enhancement in the visibility and the contrast when the fourth-order spatial correlation function is measured with quadruple coincidence measurement in the single photon counting regime. The resolution, however, is not changed when we scan three of four detectors with identical speed and direction. But if we scan two of three detectors in opposite directions and same speed, simultaneously, other two in identical direction and speed of one detector is twice of that of the other, we can see that both the contrast and resolution are improved significantly. We also show that the conclusion can be applied to the Nth-order ghost imaging.
We investigate the fourth-order spatial correlation properties of pseudo-thermal light in the photon counting regime, and apply the Klyshko advanced-wave picture to describe the process of four-photon coincidence counting measurement. We deduce the theory of a proof-of-principle four-photon coincidence counting configuration, and find that if the four randomly radiated photons come from the same radiation area and are indistinguishable in principle, the fourth-order correlation of them is 24 times larger than that when four photons come from different radiation areas. In addition, we also show that the higher-order spatial correlation function can be decomposed into multiple lower-order correlation functions, and the contrast and visibility of low-order correlation peaks are less than those of higher orders, while the resolutions all are identical. This study may be useful for better understanding the four-photon interference and multi-channel correlation imaging.