Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optical atomic magnetometer

Dmitry Budker

Published Jan 23, 2023• 0 citations
OpenAlex

Abstract

An optical atomic magnetometers is provided operating on the principles of nonlinear magneto-optical rotation. An atomic vapor is optically pumped using linearly polarized modulated light. The vapor is then probed using a non-modulated linearly polarized light beam. The resulting modulation in polarization angle of the probe light is detected and used in a feedback loop to induce self-oscillation at the resonant frequency.

Related papers

Self-oscillating rubidium magnetometer using nonlinear magneto-optical rotation

Peter D. D. Schwindt, Leo W. Hollberg, John E. Kitching

The detection of nonlinear magneto-optical rotation (NMOR) of polarized light through alkali atomic vapor is a highly sensitive technique for measuring magnetic fields. We demonstrate that when using frequency modulated light to excite the NMOR resonance, it is possible to cause the system to self-oscillate. The NMOR signal is not a simple replica of the sine wave modulation of the light, but rather contains many higher harmonics of the modulation frequency, and we implement two ways of processing the signal to recover the fundamental modulation frequency in the feedback loop and induce self-oscillation. Self-oscillation simplifies and reduces the power consumption of the electronics required to operate a magnetometer, making the NMOR technique attractive for commercialized magnetic sensors.

Review of Scientific Instruments•Dec 1, 2005•56 citations

Sensitive optical atomic magnetometer based on nonlinear magneto-optical rotation

Chris Hovde, Brian Patton, Eric Corsini +2 more

A self-oscillating magnetometer based on nonlinear magneto-optical rotation using amplitude-modulated pump light and unmodulated probe light (AM-NMOR) in 87Rb has been constructed and tested towards a goal of airborne detection of magnetic anomalies. In AM-NMOR, stroboscopic optical pumping via amplitude modulation of the pump beam creates alignment of the ground electronic state of the rubidium atoms. The Larmor precession causes an ac rotation of the polarization of a separate probe beam; the polarization rotation frequency provides a measure of the magnetic field. An anti-relaxation coating on the walls of the atomic vapor cell results in a long lifetime of 56 ms for the alignment, which enables precise measurement of the precession frequency. Light is delivered to the magnetometer by polarization-maintaining optical fibers. Tests of the sensitivity include directly measuring the beat frequency between the magnetometer and a commercial instrument and measurements of Earth's field under magnetically quiet conditions, indicating a sensitivity of at least 5 pT/νHz. Rotating the sensor indicates a heading error of less than 1 nT, limited in part by residual magnetism of the sensor.

arXiv:1003.1531•Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Apr 23, 2010•5 citations

Pump-probe nonlinear magneto-optical rotation with frequency-modulated light

Szymon Pustelny, Derek F. Jackson Kimball, Simon Rochester +3 more

Specific types of atomic coherences between Zeeman sublevels can be generated and detected using a method based on nonlinear magneto-optical rotation with frequency-modulated light. Linearly polarized, frequency-modulated light is employed to selectively generate ground-state coherences between Zeeman sublevels for which $\mathrm{\ensuremath{\Delta}}m=2$ and $\mathrm{\ensuremath{\Delta}}m=4$ in $^{85}\mathrm{Rb}$ and $^{87}\mathrm{Rb}$ atoms, and additionally $\mathrm{\ensuremath{\Delta}}m=6$ in $^{85}\mathrm{Rb}$. The atomic coherences are detected with a separate, unmodulated probe light beam. Separation of the pump and probe beams enables independent investigation of the processes of creation and detection of the atomic coherences. With the present technique the transfer of the Zeeman coherences, including high-order coherences, from excited to ground state by spontaneous emission has been observed.

arXiv:physics/0511123•Physical Review A•Feb 21, 2006•49 citations

All-optical atomic magnetometers based on nonlinear magneto-optical rotation with amplitude modulated light

Szymon Pustelny, Adam M. Wojciechowski, M. Kotyrba +11 more

We demonstrate a magnetometric technique based on nonlinear magneto-optical rotation using amplitude modulated light. The magnetometers can be operated in either open-loop (typical nonlinear magneto-optical rotation with amplitude-modulated light) or closed-loop (self-oscillating) modes. The latter mode is particularly well suited for conditions where the magnetic field is changing by large amounts over a relatively short timescale.

arXiv:physics/0610253•Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Mar 2, 2007•7 citations

Method for Implementing Optical Phase Adjustment

D. C. Hovde, Eric Corsini

A method has been developed to mechanically implement the optical phase shift by adjusting the polarization of the pump and probe beams in an NMOR (nonlinear magneto-optical rotation) magnetometer as the proper phase shift is necessary to induce self-oscillation. This innovation consists of mounting the pump beam on a ring that surrounds the atomic vapor sample. The propagation of the probe beam is perpendicular to that of the pump beam. The probe beam can be considered as defining the axis of a cylinder, while the pump beam is directed radially. The magnetic field to be measured defines a third vector, but it is also taken to lie along the cylinder axis. Both the pump and probe beams are polarized such that their electric field vectors are substantially perpendicular to the magnet field. By rotation of the ring supporting the pump beam, its direction can be varied relative to the plane defined by the probe electric field and the magnetic field to be measured.

•Jan 1, 2011•0 citations

Rubidium atomic magnetometer based on pump-probe nonlinear magneto-optical rotation

Pei-Xian Miao, Shiyu Yang, Wang Jian-Xiang +4 more

We report a rubidium atomic magnetometer based on pump-probe nonlinear magneto-optical rotation. The rubidium vapor cell is placed in a five-layer magnetic shield with inner coils that can generate uniform magnetic fields along the direction of pump beam, and the cell is also placed in the center of a Helmholtz coil that can generate an oscillating magnetic field perpendicular to the direction of pump beam. The atoms are optically pumped by circularly polarized pump beam along a constant magnetic field in a period of time, then the pump beam is turned off and a /2 pulse of oscillating magnetic field for 87Rb atoms is applied. After the above process, the individual atomic magnetic moments become phase coherent, resulting in a transverse magnetization vector precessing at the Larmor frequency in the magnetic field. The linearly polarized probing beam is perpendicular to the direction of magnetic field, and can be seen as a superposition of the left and right circularly polarized light. Because of the different absorptions and dispersions of the left and right circularly polarized light by rubidium atoms, the polarization direction of probing beam rotates when probing beam passes through rubidium vapor cell. The rotation of the polarization is subsequently converted into an electric signal through a polarizing beam splitter. Finally, the decay signal related to the transverse magnetization vector is measured. The Larmor frequency proportional to magnetic field is obtained by the Fourier transform of the decay signal. The value of magnetic field is calculated from the formula:B=(2/) f, where and f are the gyromagnetic ratio and Larmor frequency, respectively. In order to measure the magnetic field in a wide range, the tracking lock mode is proposed and tested. The atomic magnetometer can track the magnetic field jump of 1000 nT or 10000 nT, indicating that the atomic magnetometer has strong locking ability and can be easily locked after start-up. The main performances in different magnetic fields are tested. The results show that the measurement range of the atomic magnetometer is from 100 nT to 100000 nT, the extreme sensitivity is 0.2 pT/Hz1/2, and the magnetic field resolution is 0.1 pT. The transverse relaxation times of the transverse magnetization vector in different magnetic fields are obtained, and the relaxation time decreases with the increase of the magnetic field. When the measurement range is from 5000 nT to 100000 nT, the magnetic field sampling rate of the atomic magnetometer can be adjusted in a range from 1 Hz to 1000 Hz. The atomic magnetometer in high sampling rate can measure weak alternating magnetic field at low frequency. This paper provides an important reference for developing the atomic magnetometer with large measurement range, high sensitivity and high sampling rate.

Acta Physica Sinica•Jan 1, 2017•12 citations
An optical atomic magnetometers is provided operating on the principles of nonlinear magneto-optical rotation. An atomic vapor is optically pumped using linearly polarized modulated light. The vapor is then probed using a non-modulated linearly polarized light beam. The resulting modulation in polarization angle of the probe light is detected and used in a feedback loop to induce self-oscillation at the resonant frequency.
The detection of nonlinear magneto-optical rotation (NMOR) of polarized light through alkali atomic vapor is a highly sensitive technique for measuring magnetic fields. We demonstrate that when using frequency modulated light to excite the NMOR resonance, it is possible to cause the system to self-oscillate. The NMOR signal is not a simple replica of the sine wave modulation of the light, but rather contains many higher harmonics of the modulation frequency, and we implement two ways of processing the signal to recover the fundamental modulation frequency in the feedback loop and induce self-oscillation. Self-oscillation simplifies and reduces the power consumption of the electronics required to operate a magnetometer, making the NMOR technique attractive for commercialized magnetic sensors.
A self-oscillating magnetometer based on nonlinear magneto-optical rotation using amplitude-modulated pump light and unmodulated probe light (AM-NMOR) in 87Rb has been constructed and tested towards a goal of airborne detection of magnetic anomalies. In AM-NMOR, stroboscopic optical pumping via amplitude modulation of the pump beam creates alignment of the ground electronic state of the rubidium atoms. The Larmor precession causes an ac rotation of the polarization of a separate probe beam; the polarization rotation frequency provides a measure of the magnetic field. An anti-relaxation coating on the walls of the atomic vapor cell results in a long lifetime of 56 ms for the alignment, which enables precise measurement of the precession frequency. Light is delivered to the magnetometer by polarization-maintaining optical fibers. Tests of the sensitivity include directly measuring the beat frequency between the magnetometer and a commercial instrument and measurements of Earth's field under magnetically quiet conditions, indicating a sensitivity of at least 5 pT/νHz. Rotating the sensor indicates a heading error of less than 1 nT, limited in part by residual magnetism of the sensor.
Specific types of atomic coherences between Zeeman sublevels can be generated and detected using a method based on nonlinear magneto-optical rotation with frequency-modulated light. Linearly polarized, frequency-modulated light is employed to selectively generate ground-state coherences between Zeeman sublevels for which $\mathrm{\ensuremath{\Delta}}m=2$ and $\mathrm{\ensuremath{\Delta}}m=4$ in 85Rb^{85}\mathrm{Rb}85Rb and 87Rb^{87}\mathrm{Rb}87Rb atoms, and additionally $\mathrm{\ensuremath{\Delta}}m=6$ in 85Rb^{85}\mathrm{Rb}85Rb. The atomic coherences are detected with a separate, unmodulated probe light beam. Separation of the pump and probe beams enables independent investigation of the processes of creation and detection of the atomic coherences. With the present technique the transfer of the Zeeman coherences, including high-order coherences, from excited to ground state by spontaneous emission has been observed.
A method has been developed to mechanically implement the optical phase shift by adjusting the polarization of the pump and probe beams in an NMOR (nonlinear magneto-optical rotation) magnetometer as the proper phase shift is necessary to induce self-oscillation. This innovation consists of mounting the pump beam on a ring that surrounds the atomic vapor sample. The propagation of the probe beam is perpendicular to that of the pump beam. The probe beam can be considered as defining the axis of a cylinder, while the pump beam is directed radially. The magnetic field to be measured defines a third vector, but it is also taken to lie along the cylinder axis. Both the pump and probe beams are polarized such that their electric field vectors are substantially perpendicular to the magnet field. By rotation of the ring supporting the pump beam, its direction can be varied relative to the plane defined by the probe electric field and the magnetic field to be measured.
We report a rubidium atomic magnetometer based on pump-probe nonlinear magneto-optical rotation. The rubidium vapor cell is placed in a five-layer magnetic shield with inner coils that can generate uniform magnetic fields along the direction of pump beam, and the cell is also placed in the center of a Helmholtz coil that can generate an oscillating magnetic field perpendicular to the direction of pump beam. The atoms are optically pumped by circularly polarized pump beam along a constant magnetic field in a period of time, then the pump beam is turned off and a /2 pulse of oscillating magnetic field for 87Rb atoms is applied. After the above process, the individual atomic magnetic moments become phase coherent, resulting in a transverse magnetization vector precessing at the Larmor frequency in the magnetic field. The linearly polarized probing beam is perpendicular to the direction of magnetic field, and can be seen as a superposition of the left and right circularly polarized light. Because of the different absorptions and dispersions of the left and right circularly polarized light by rubidium atoms, the polarization direction of probing beam rotates when probing beam passes through rubidium vapor cell. The rotation of the polarization is subsequently converted into an electric signal through a polarizing beam splitter. Finally, the decay signal related to the transverse magnetization vector is measured. The Larmor frequency proportional to magnetic field is obtained by the Fourier transform of the decay signal. The value of magnetic field is calculated from the formula:B=(2/) f, where and f are the gyromagnetic ratio and Larmor frequency, respectively. In order to measure the magnetic field in a wide range, the tracking lock mode is proposed and tested. The atomic magnetometer can track the magnetic field jump of 1000 nT or 10000 nT, indicating that the atomic magnetometer has strong locking ability and can be easily locked after start-up. The main performances in different magnetic fields are tested. The results show that the measurement range of the atomic magnetometer is from 100 nT to 100000 nT, the extreme sensitivity is 0.2 pT/Hz1/2, and the magnetic field resolution is 0.1 pT. The transverse relaxation times of the transverse magnetization vector in different magnetic fields are obtained, and the relaxation time decreases with the increase of the magnetic field. When the measurement range is from 5000 nT to 100000 nT, the magnetic field sampling rate of the atomic magnetometer can be adjusted in a range from 1 Hz to 1000 Hz. The atomic magnetometer in high sampling rate can measure weak alternating magnetic field at low frequency. This paper provides an important reference for developing the atomic magnetometer with large measurement range, high sensitivity and high sampling rate.