We show an optical heterodyne spectrometer with picometer resolution and high sensitivity. Moreover, we report the quantum limit of detecting multi-mode light using heterodyne detection, and compare it to a typical down conversion source output.
Optical heterodyne detection-based spectrometers are attractive due to their relatively simple construction and ultrahigh resolution. Here we demonstrate a proof-of-principle single-mode optical-fiber-based heterodyne spectrometer that has picometer resolution and quantum-limited sensitivity around 1550 nm. Moreover, we report a generalized quantum limit of detecting broadband multispectral-temporal-mode light using heterodyne detection, which provides a sensitivity limit on a heterodyne detection-based optical spectrometer. We then compare this sensitivity limit to several spectrometer types and dim light sources of interest such as spontaneous parametric downconversion, Raman scattering, and spontaneous four-wave mixing. We calculate that the heterodyne spectrometer is significantly less sensitive than a single-photon detector and is unable to detect these dim light sources, except for the brightest and narrowest-bandwidth examples.
The distance between two point light sources is difficult to estimate if that distance is below the diffraction (Rayleigh's) resolution limit of the imaging device. A recently proposed technique enhances the precision of this estimation by exploiting the source-separation-dependent coupling of light into higher-order transverse-electromagnetic (TEM) modes, particularly the TEM01 mode of the image. We theoretically analyze the estimation of the source separation by means of homodyne or heterodyne detection with a local oscillator in the TEM01 mode, which is maximally sensitive to the separation in the sub-Rayleigh regime. We calculate the Fisher information associated with this estimation and compare it with direct imaging. For thermal sources, the Fisher information in any mode of the image plane depends nonlinearly on the average received photon number. We show that the per-photon Fisher information surpasses that of direct imaging (in the interesting sub-Rayleigh regime) when the average received photon number per source exceeds two for homodyne detection and four for heterodyne detection.
A photorefractive adaptive optical heterodyne detection system is proposed. Its principle is introduced and typical numerical calculation is illustrated, which includes the reference beam output power and minimum detectable signal power versus system global power ratio, the effect of crystal coupling strength on reference beam output power and minimum detectable signal power, and the minimum detectable signal power versus nonlinear coupling strength. Several key factors which affect the system characteristics strongly are pointed out. In the proposed system, only one photorefractive crystal is used to attain optical heterodyne detection. The system features simple structure, low noise and high responsibility. It also answers two key questions of heterodyne detection: 1) phase distortion; 2) coherent length of light source.