Precisely measuring the three-dimensional position and orientation of individual fluorophores is challenging due to the substantial photon shot noise in single-molecule experiments. Facing this limited photon budget, numerous techniques have been developed to encode 2D and 3D position and 2D and 3D orientation information into fluorescence images. In this work, we adapt classical and quantum estimation theory and propose a mathematical framework to derive the best possible precision for measuring the position and orientation of dipole-like emitters for any fixed imaging system. We find that it is impossible to design an instrument that achieves the maximum sensitivity limit for measuring all possible rotational motions. Further, our vectorial dipole imaging model shows that the best quantum-limited localization precision is 4%-8% worse than that suggested by a scalar monopole model. Overall, we conclude that no single instrument can be optimized for maximum precision across all possible 2D and 3D localization and orientation measurement tasks.
Abstract We present a quantum sensing protocol for the simultaneous estimation of the difference in the localization parameters of two single-photon sources, paving the way to single-photon 3D imaging and 3D nanoscopy beyond the diffraction limit. This is achieved by exploiting two-photon interference of the two emitted photons at a beam splitter via sampling measurements in the frequency and transverse momenta at the output. We prove theoretically that this technique reaches the ultimate sensitivity in the 3D relative localization of two emitters, already with a number of sampling measurements of
∼2000 ∼ 2000 and a bias in the three localization parameters below
1% 1 % . These results are independent of the values of the localization parameters to estimate.