Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics Express

Spatial filtering of Zeeman sub-states in an atomic fountain

Xiaolong Wang, Gewen Sun, Bing Cheng, Bin Wu, Helin Wang, Zhaoying Wang, Jing Wang, Chunlin Chen, Li-Ming Wu, Shaohua Chang, Junze Tong, Rongrong Ma, Yafei Feng, Wenbin Xie, Qiang Lin

Published May 30, 2022• 1 citation
Publisher

Abstract

In an atomic fountain, atoms in motion can be spatially separated into discrete Zeeman sub-states by magnetically induced Stern-Gerlach effect. With resonant light pulses acting as a shutter, specific states are selected for subsequent experiments. Such separation-selection process in atomic optics is the analogue of a spatial filter in physical optics which selects and purifies the modes of light. This technique is demonstrated by injecting a pulsed current in a circular coil around a vertical atomic fountain, separating the pre-cooled Rubidium atoms by a distance of centimeters in between, and filtering each single sub-state with block pulses. The filtered atoms after the process is highly purified in the desired sub-state. The apparatus of the atomic spatial filter is adaptable in atomic optics and can be integrated into the high-vacuum chamber of an atomic fountain.

DOI
10.1364/oe.457610

Related papers

Nonlinear focusing of atom clouds by a short-focal-length magnetic lens

Jing Wang, Ziqian Wang, Shan Hua +14 more

Utilizing the Stern-Gerlach effect, magnetic lenses are used to focus atom clouds, reducing their dimensions, and boosting the central cloud density. In this research, a theoretical model based on nonlinear Zeeman splitting in high-intensity magnetic fields is established to explore the nonlinear focusing of a tightly focused magnetic lens. The research concentrates on the motion and focusing of 87 Rb atoms in various Zeeman substates within an atom fountain under pulsed magnetic fields and establishes a correlation between the field curvature and the effective focal length. The nonlinear model has been validated in the experiment conducted in the fountain. Atoms in different Zeeman substates were selectively focused by the magnetic lens which has applications in precise manipulation of atoms including collimation, concentration, and spatial filtering. A spatial filter based on this method has been deployed in the phase-shear atomic interferometer to prepare an atom cloud in a pure Zeeman substate.

Optics Express•Jun 13, 2025•0 citations

Atomic spatial coherence monitoring and engineering with magnetic fields

O. Gorceix, É. Maréchal, T. Miossec +4 more

Summary form only given. Spatial coherences are measured by means of a new atom interferometry technique. First, a coherent superposition of the Zeeman components of the atom is built by means of well-controlled magnetic interactions. Second, pulsed inhomogeneous magnetic fields are employed to coherently separate and reunite the atomic substates via the Stern-Gerlach induced forces. Finally, atomic interference fringes are recorded on the state-selected outcoming sample by changing the spatial separation. This method bears strong similarities with the Fourier-transform spectroscopy of light. The interferogram visibility curve yields the atom sample spatial coherences. For example, when the applied magnetic gradients are parallel to the atom trajectory, one gets the coherence length by varying the overlap of the separated wavepackets. Several experiments on cold cesium atoms have been performed and are presented. Furthermore, we have used our magnetic cooling method to prepare the atom cloud upstream from the interferometer. Large enhancements of the coherence length are demonstrated.

Conference on Lasers and Electro-Optics•Aug 29, 2005•0 citations

Optical Stern-Gerlach effect from the Zeeman-like ac Stark shift

Chang Yong Park, Ji Young Kim, Jong Min Song +1 more

We report a different type of optical Stern-Gerlach effect, where a magnetic-field gradient is replaced with a light-intensity gradient and a paramagnetic atom is deflected according to its magnetic quantum number. The laser light is detuned between the $D1$ and $D2$ frequencies, with the size of the detuning from the $D2$ resonance being twice that from the $D1$ resonance, and it is circularly polarized to produce an ac Stark shift that takes the form of a pure Zeeman shift. Slow rubidium atoms are extracted from a magneto-optical trap and then spin polarized. The atoms traversing the laser-intensity gradient on one side of the Gaussian beam profile show deflections that depend on the atomic spin state and the laser polarization. When the laser-beam axis is aligned with the slit that defines the atomic beam, we observe focusing and defocusing of the atomic beam.

Physical Review A•Feb 20, 2002•25 citations

Effect of selective saturated absorption on atomic line filter

Shuangqiang Liu, Weimin Sun

We report an atomic filter based on optical pumping induced anisotropy in Doppler-broadened two-level atoms. Atomic line filters (ALF) in previous research used a selective pump to populate atoms on special Zeeman sub-levels to obtain optical anisotropy because of dipole selection rules. Unlike them, we proposed a novel method to get circular anisotropy realized by selectively saturated absorption in rubidium.

International Conference on Optoelectronics and Microelectronics•Sep 1, 2013•0 citations

Efficient quantum state preparation using Stern–Gerlach effect on cold atoms

Vivek Singh, Vibhuti Bhushan Tiwari, Satya Ram Mishra

Abstract The Zeeman hyperfine state dependent force in a Stern–Gerlach experiment has been exploited to separate and quantitatively detect atoms in different Zeeman hyperfine states in a cold atom cloud of 87 Rb atoms. Using this atomic state detection technique, the quantum state of the atom cloud has been prepared with high efficiency for magnetic trapping application.

arXiv:2201.01589•Measurement Science and Technology•Jun 14, 2022•2 citations

Optically polarized selection in atomic vapor and its application in mapping the polarization distribution

Jinwen Wang, Yun Chen, Xin Yang +8 more

Abstract Based on the dichroism induced by the optical pumping effect, a novel and effective configuration to select an arbitrary polarization distribution is proposed. The influence of the distribution of atoms in different Zeeman sub-levels is the main cause to realize the measurement or ‘filtration’ of the state of polarization. A detailed process of the optical pumping effect in our configurations is presented in the theoretical analysis. In the experiment, the flexible function of the atomic medium, such as a polarizer or a polarized filter can efficiently be realized by different polarizations of the pump beam. Four different kinds of vector beams are tested and the ability to analyze any kind of beam with arbitrary polarization distribution is proven in agreement with the prediction. This work has potential applications in atomic physics and polarization optics. Furthermore, it can provide a reference to atom-optical elements and atom-optical devices.

Journal of Physics Communications•Jan 1, 2020•8 citations
In an atomic fountain, atoms in motion can be spatially separated into discrete Zeeman sub-states by magnetically induced Stern-Gerlach effect. With resonant light pulses acting as a shutter, specific states are selected for subsequent experiments. Such separation-selection process in atomic optics is the analogue of a spatial filter in physical optics which selects and purifies the modes of light. This technique is demonstrated by injecting a pulsed current in a circular coil around a vertical atomic fountain, separating the pre-cooled Rubidium atoms by a distance of centimeters in between, and filtering each single sub-state with block pulses. The filtered atoms after the process is highly purified in the desired sub-state. The apparatus of the atomic spatial filter is adaptable in atomic optics and can be integrated into the high-vacuum chamber of an atomic fountain.
Utilizing the Stern-Gerlach effect, magnetic lenses are used to focus atom clouds, reducing their dimensions, and boosting the central cloud density. In this research, a theoretical model based on nonlinear Zeeman splitting in high-intensity magnetic fields is established to explore the nonlinear focusing of a tightly focused magnetic lens. The research concentrates on the motion and focusing of 87 Rb atoms in various Zeeman substates within an atom fountain under pulsed magnetic fields and establishes a correlation between the field curvature and the effective focal length. The nonlinear model has been validated in the experiment conducted in the fountain. Atoms in different Zeeman substates were selectively focused by the magnetic lens which has applications in precise manipulation of atoms including collimation, concentration, and spatial filtering. A spatial filter based on this method has been deployed in the phase-shear atomic interferometer to prepare an atom cloud in a pure Zeeman substate.
Summary form only given. Spatial coherences are measured by means of a new atom interferometry technique. First, a coherent superposition of the Zeeman components of the atom is built by means of well-controlled magnetic interactions. Second, pulsed inhomogeneous magnetic fields are employed to coherently separate and reunite the atomic substates via the Stern-Gerlach induced forces. Finally, atomic interference fringes are recorded on the state-selected outcoming sample by changing the spatial separation. This method bears strong similarities with the Fourier-transform spectroscopy of light. The interferogram visibility curve yields the atom sample spatial coherences. For example, when the applied magnetic gradients are parallel to the atom trajectory, one gets the coherence length by varying the overlap of the separated wavepackets. Several experiments on cold cesium atoms have been performed and are presented. Furthermore, we have used our magnetic cooling method to prepare the atom cloud upstream from the interferometer. Large enhancements of the coherence length are demonstrated.
We report a different type of optical Stern-Gerlach effect, where a magnetic-field gradient is replaced with a light-intensity gradient and a paramagnetic atom is deflected according to its magnetic quantum number. The laser light is detuned between the D1D1D1 and D2D2D2 frequencies, with the size of the detuning from the D2D2D2 resonance being twice that from the D1D1D1 resonance, and it is circularly polarized to produce an ac Stark shift that takes the form of a pure Zeeman shift. Slow rubidium atoms are extracted from a magneto-optical trap and then spin polarized. The atoms traversing the laser-intensity gradient on one side of the Gaussian beam profile show deflections that depend on the atomic spin state and the laser polarization. When the laser-beam axis is aligned with the slit that defines the atomic beam, we observe focusing and defocusing of the atomic beam.
Abstract Based on the dichroism induced by the optical pumping effect, a novel and effective configuration to select an arbitrary polarization distribution is proposed. The influence of the distribution of atoms in different Zeeman sub-levels is the main cause to realize the measurement or ‘filtration’ of the state of polarization. A detailed process of the optical pumping effect in our configurations is presented in the theoretical analysis. In the experiment, the flexible function of the atomic medium, such as a polarizer or a polarized filter can efficiently be realized by different polarizations of the pump beam. Four different kinds of vector beams are tested and the ability to analyze any kind of beam with arbitrary polarization distribution is proven in agreement with the prediction. This work has potential applications in atomic physics and polarization optics. Furthermore, it can provide a reference to atom-optical elements and atom-optical devices.