The study of ion-molecule reactions plays a vital role in cold chemistry, thus implying the need of well-controlled ion ensembles in a cold environment. The internal and external degrees of freedom of molecular ions, trapped in multipole radio frequency ion traps, can be cooled via collisions with neutral atoms [1]. Usually the coolant undergoes collisions with a thermal shield mounted on a cryostat attaining temperatures of about 4 K. To overcome this lower temperature limit two approaches have been proposed. Firstly, using a laser-cooled buffer-gas localized at the center of the ion cloud [2]. Secondly, sympathetic cooling via a second laser cooled molecular anion like C
2− [3]. This, in addition to its potential role in forming carbon chain anions in the interstellar medium, makes C
2− an important molecule in anion research. In this contribution we present a newly developed 16-pole cryogenic radio frequency wire trap for spectroscopic and kinetic studies of molecular anions. First results of quenching rates of the first excited vibrational level of C
2− due to collisions with H
2 are presented. Furthermore, possible reaction pathways with H
2 are discussed and recent spectroscopic measurements of the second electronic excited state of C
2− are presented. References: [1] R. Wester , J. Phys. B 42, 154001 (2009) [2] B. Höltkemeier et al., Phys. Rev. A 94, 062703, (2016) [3] P. Yzombard et al., Phys. Rev. Lett. 114, 213001 (2015)
Abstract We demonstrate the precise in situ measurement of extreme-high vacuum (XHV) in a cryogenic linear Paul trap operating at 5.7 K, utilizing laser-cooled Be + Coulomb crystals as dual-mode quantum probes. Two independent methods, elastic collision rate monitoring and reaction rate analysis, were employed to determine the vacuum level within the cryogenic linear Paul trap. Based on the collision rate of a single trapped beryllium ion with background gas, which was measured as 1.3(7) × 10 −4 Hz, the pressure under cryogenic conditions was calculated to be 6.0(3.4) × 10 −12 Pa. Alternatively, by leveraging the reaction rate of Be + ions with background gases, a pressure of 8.4(1) × 10 −12 Pa was obtained. The mutual agreement between these two methods validates the reliability of cold-atom-based vacuum metrology at the 10 −12 Pa scale, successfully overcoming the detection limits of conventional vacuum gauges. This approach, which capitalizes on the unique mass properties and photostability of Be + ions, fills a critical gap in XHV metrology and paves the way for the development of chip-trap-integrated in situ vacuum sensing technologies.
Using helium buffer gas cooling, we have prepared dense samples of ground-state molecular calcium monohydride (CaH X 2Σ) at cryogenic temperatures. We have used optical pumping to polarise the spin state of the CaH molecules and we have measured the inelastic collisions of molecular CaH with atomic helium at temperatures from 2 to 7 K. The measured CaH electronic spin depolarisation rate coefficient increases rapidly with increasing temperature, increasing from 2 × 10−13 cm3 s−1 to over 10−11 cm3 s−1. The strong dependence of rate coefficient on temperature is attributed to the CaH population in the first excited rotational state.