Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

npj Quantum Information

Towards a microwave single-photon counter for searching axions

A. L. Pankratov, L. S. Revin, Anna V. Gordeeva, Anton A. Yablokov, L. S. Kuzmin, Evgeni V. Il’ichev

Published May 18, 2022• 50 citations
Publisher

Abstract

Abstract The major task of detecting axions or axion-like particles has two challenges. On the one hand, the ultimate sensitivity is required, down to the energy of a single microwave photon of the yoctojoule range. On the other hand, since the detected events are supposed to be rare, the dark count rate of the detector must be extremely low. We show that this trade-off can be approached due to the peculiar switching dynamics of an underdamped Josephson junction in the phase diffusion regime. The detection of a few photons’ energy at 10 GHz with dark count time above 10 s and the efficiency close to unity was demonstrated. Further enhancements require a detailed investigation of the junction switching dynamics.

DOI
10.1038/s41534-022-00569-5

Related papers

Stepping Closer to Pulsed Single Microwave Photon Detectors for Axions Search

Alessandro D’Elia, A. Rettaroli, S. Tocci +23 more

Axions detection requires the ultimate sensitivity down to the single-photon limit. In the microwave region, this corresponds to energies in the yJ range. This extreme sensitivity has to be combined with an extremely low dark-count rate since the probability of axions conversion into microwave photons is supposed to be very low. To face this complicated task, we followed two promising approaches that both rely on the use of superconducting devices based on the Josephson effect. The first one is to use a single Josephson junction (JJ) as a switching detector (i.e., exploiting the superconducting to normal state transition in the presence of microwave photons). We designed a device composed of a coplanar waveguide terminated on a current-biased JJ. We tested its efficiency to pulsed (pulse duration 10 ns) microwave signals since this configuration is closer to an actual axions search experiment. We show how our device is able to reach detection capability of the order of ten photons with the frequency of 8 GHz. The second approach is based on an intrinsically quantum device formed by two resonators coupled only via a superconducting qubit network. This approach relies on quantum nondemolition measurements of the resonator photons. We show that by injecting radiofrequency power into the resonator, the frequency position of the resonant drop in the transmission coefficient (S21) can be modulated up to 4 MHz. We anticipate that, once optimized, both the devices have the potential to reach single-photon sensitivity.

arXiv:2302.07556•IEEE Transactions on Applied Superconductivity•Nov 4, 2022•20 citations

Single Photon Counter Based on a Josephson Junction at 14 GHz for Searching Galactic Axions

L. S. Kuzmin, Alexander S. Sobolev, Claudio D. Gatti +4 more

Axions and axion-like particles appear in well-motivated extensions of the standard model of particle physics and may be the solution to the long-standing puzzle of the dark matter in our Universe. Several new experiments are foreseen in the next decade searching them in a wide range of the parameter space. In the mass region from few to several tens of microelectronvolt, detector sensitivity will be limited by the standard quantum limit of linear amplifiers and a new class of single microwave-photon detector will be needed. We have developed a single photon counter based on the voltage switching of an underdamped Josephson junction that is coupled to a coplanar waveguide. By measuring the switching voltage, we can register single photons at 14 GHz with the rate less than 1 photon per 3000 s.

IEEE Transactions on Applied Superconductivity•Jul 19, 2018•50 citations

Single-Photon Detection with a Josephson Junction Coupled to a Resonator

Dmitry S. Golubev, Evgeni V. Il’ichev, L. S. Kuzmin

We use a semiclassical formalism to optimize a microwave single-photon detector based on switching events of a current-biased Josephson junction coupled to a resonator. To detect very rare events, the average time between dark counts ${\ensuremath{\tau}}_{\mathrm{dark}}$ should be maximized taking into account that the switching time ${\ensuremath{\tau}}_{\mathrm{sw}}$ should be sufficiently small. We demonstrate that these times can be tuned in a wide range by changing the junction parameters, and ${\ensuremath{\tau}}_{\mathrm{dark}}/{\ensuremath{\tau}}_{\mathrm{sw}}\ensuremath{\sim}{10}^{9}$ can be achieved. Therefore, a junction-resonator arrangement can be used to detect extremely low photon fluxes (e.g., for searching for galactic axions).

arXiv:2107.08113•Physical Review Applied•Jul 9, 2021•24 citations

Development of a Josephson junction based single photon microwave detector for axion detection experiments

D Alesini, D Babusci, C. Barone +30 more

Abstract Josephson junctions, in appropriate configurations, can be excellent candidates for detection of single photons in the microwave frequency band. Such possibility has been recently addressed in the framework of galactic axion detection. Here are reported recent developments in the modelling and simulation of dynamic behaviour of a Josephson junction single microwave photon detector. For a Josephson junction to be enough sensitive, small critical currents and operating temperatures of the order of ten of mK are necessary. Thermal and quantum tunnelling out of the zero-voltage state can also mask the detection process. Axion detection would require dark count rates in the order of 0.001 Hz. It is, therefore, is of paramount importance to identify proper device fabrication parameters and junction operation point.

arXiv:2107.01118•Journal of Physics Conference Series•Jun 1, 2020•13 citations

Detection of 5 GHz photons using Al Josephson junctions at 0.7 K

Dmitry A. Ladeynov, A. L. Pankratov, L. S. Revin +4 more

We predict that threshold detectors based on Al Josephson junctions with critical currents below 100 nA exhibiting a phase diffusion regime can be exploited for microwave photon detection at both 17 mK and 700 mK. We demonstrate the detection of two- and one-photon energies at 5 GHz with 90% and 15% efficiency and dark count times of about 0.1 s and 0.01 s, respectively. The weak temperature dependence of the detector’s performance observed in the sub-kelvin range fully confirms its phase diffusion mode of operation. On the other hand, these results show that inevitable thermal fluctuations are not the main source of detector noise. Consequently, there is still room to optimize the detector’s performance. These results are important for axion search experiments in the range of 5–25 GHz (20–100 μeV).

arXiv:2405.04426•Academia quantum.•Jun 27, 2025•2 citations

Josephson Junctions as Single Microwave Photon Counters: Simulation and Characterization

A. Rettaroli, D. Alesini, D. Babusci +17 more

Detection of light dark matter, such as axion-like particles, puts stringent requirements on the efficiency and dark-count rates of microwave-photon detectors. The possibility of operating a current-biased Josephson junction as a single-microwave photon-detector was investigated through numerical simulations, and through an initial characterization of two Al junctions fabricated by shadow mask evaporation, done in a dilution refrigerator by measuring escape currents at different temperatures, from 40 mK up to the Al transition temperature. The escape dynamics of the junctions were reproduced in the simulation, including the dissipative effects. Inhibition of thermal activation was observed, leaving the macroscopic quantum tunneling as the dominant effect well beyond the crossover temperature.

Instruments•Jul 16, 2021•14 citations
Abstract The major task of detecting axions or axion-like particles has two challenges. On the one hand, the ultimate sensitivity is required, down to the energy of a single microwave photon of the yoctojoule range. On the other hand, since the detected events are supposed to be rare, the dark count rate of the detector must be extremely low. We show that this trade-off can be approached due to the peculiar switching dynamics of an underdamped Josephson junction in the phase diffusion regime. The detection of a few photons’ energy at 10 GHz with dark count time above 10 s and the efficiency close to unity was demonstrated. Further enhancements require a detailed investigation of the junction switching dynamics.
Axions detection requires the ultimate sensitivity down to the single-photon limit. In the microwave region, this corresponds to energies in the yJ range. This extreme sensitivity has to be combined with an extremely low dark-count rate since the probability of axions conversion into microwave photons is supposed to be very low. To face this complicated task, we followed two promising approaches that both rely on the use of superconducting devices based on the Josephson effect. The first one is to use a single Josephson junction (JJ) as a switching detector (i.e., exploiting the superconducting to normal state transition in the presence of microwave photons). We designed a device composed of a coplanar waveguide terminated on a current-biased JJ. We tested its efficiency to pulsed (pulse duration 10 ns) microwave signals since this configuration is closer to an actual axions search experiment. We show how our device is able to reach detection capability of the order of ten photons with the frequency of 8 GHz. The second approach is based on an intrinsically quantum device formed by two resonators coupled only via a superconducting qubit network. This approach relies on quantum nondemolition measurements of the resonator photons. We show that by injecting radiofrequency power into the resonator, the frequency position of the resonant drop in the transmission coefficient (S21) can be modulated up to 4 MHz. We anticipate that, once optimized, both the devices have the potential to reach single-photon sensitivity.
Axions and axion-like particles appear in well-motivated extensions of the standard model of particle physics and may be the solution to the long-standing puzzle of the dark matter in our Universe. Several new experiments are foreseen in the next decade searching them in a wide range of the parameter space. In the mass region from few to several tens of microelectronvolt, detector sensitivity will be limited by the standard quantum limit of linear amplifiers and a new class of single microwave-photon detector will be needed. We have developed a single photon counter based on the voltage switching of an underdamped Josephson junction that is coupled to a coplanar waveguide. By measuring the switching voltage, we can register single photons at 14 GHz with the rate less than 1 photon per 3000 s.
We use a semiclassical formalism to optimize a microwave single-photon detector based on switching events of a current-biased Josephson junction coupled to a resonator. To detect very rare events, the average time between dark counts ${\ensuremath{\tau}}_{\mathrm{dark}}$ should be maximized taking into account that the switching time ${\ensuremath{\tau}}_{\mathrm{sw}}$ should be sufficiently small. We demonstrate that these times can be tuned in a wide range by changing the junction parameters, and ${\ensuremath{\tau}}_{\mathrm{dark}}/{\ensuremath{\tau}}_{\mathrm{sw}}\ensuremath{\sim}{10}^{9}$ can be achieved. Therefore, a junction-resonator arrangement can be used to detect extremely low photon fluxes (e.g., for searching for galactic axions).
Abstract Josephson junctions, in appropriate configurations, can be excellent candidates for detection of single photons in the microwave frequency band. Such possibility has been recently addressed in the framework of galactic axion detection. Here are reported recent developments in the modelling and simulation of dynamic behaviour of a Josephson junction single microwave photon detector. For a Josephson junction to be enough sensitive, small critical currents and operating temperatures of the order of ten of mK are necessary. Thermal and quantum tunnelling out of the zero-voltage state can also mask the detection process. Axion detection would require dark count rates in the order of 0.001 Hz. It is, therefore, is of paramount importance to identify proper device fabrication parameters and junction operation point.
We predict that threshold detectors based on Al Josephson junctions with critical currents below 100 nA exhibiting a phase diffusion regime can be exploited for microwave photon detection at both 17 mK and 700 mK. We demonstrate the detection of two- and one-photon energies at 5 GHz with 90% and 15% efficiency and dark count times of about 0.1 s and 0.01 s, respectively. The weak temperature dependence of the detector’s performance observed in the sub-kelvin range fully confirms its phase diffusion mode of operation. On the other hand, these results show that inevitable thermal fluctuations are not the main source of detector noise. Consequently, there is still room to optimize the detector’s performance. These results are important for axion search experiments in the range of 5–25 GHz (20–100 μeV).
Detection of light dark matter, such as axion-like particles, puts stringent requirements on the efficiency and dark-count rates of microwave-photon detectors. The possibility of operating a current-biased Josephson junction as a single-microwave photon-detector was investigated through numerical simulations, and through an initial characterization of two Al junctions fabricated by shadow mask evaporation, done in a dilution refrigerator by measuring escape currents at different temperatures, from 40 mK up to the Al transition temperature. The escape dynamics of the junctions were reproduced in the simulation, including the dissipative effects. Inhibition of thermal activation was observed, leaving the macroscopic quantum tunneling as the dominant effect well beyond the crossover temperature.