Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Uspekhi Fizicheskih Nauk

Lecture demonstration of equal-inclination interference fringes

Ya. E. Amstislavskii

Published Jan 1, 1968• 0 citations
Publisher
DOI
10.3367/ufnr.0096.196810f.0369

Related papers

Interference Fringe Demonstrations

T. C. Sayetta

American Journal of Physics•Jul 1, 1973•0 citations

Interference fringes in a nonlinear Michelson interferometer based on spontaneous parametric down-conversion

Chen Yang, Zhi‐Yuan Zhou, Liu-Long Wang +7 more

Quantum nonlinear interferometers (QNIs) can measure the infrared physical quantities of a sample by detecting visible photons. A QNI with Michelson geometry based on the spontaneous parametric down-conversion in a second-order nonlinear crystal is studied systematically. A simplified theoretical model of the QNI is presented. The interference visibility, coherence length, equal-inclination interference, and equal-thickness interference for the QNI are demonstrated theoretically and experimentally. As an application example of the QNI, the refractive index and the angle between two surfaces of a BBO crystal are measured using equal-inclination interference and equal-thickness interference.

arXiv:2109.07668•Optics Express•Sep 13, 2021•6 citations

Interference and Interferometry

Ángel S. Sanz, Salvador Miret-Artés

Lecture notes in physics•Sep 13, 2013•0 citations

Visibility of Interference Fringes and the Double Slit

J. K. Robertson

Nature•Jul 26, 1917•1 citation

Angular-spectrum-dependent interference

Chen Yang, Zhi‐Yuan Zhou, Yan Li +4 more

Optical interference is not only a fundamental phenomenon that has enabled new theories of light to be derived but it has also been used in interferometry for the measurement of small displacements, refractive index changes, and surface irregularities. In a two-beam interferometer, variations in the interference fringes are used as a diagnostic for anything that causes the optical path difference (OPD) to change; therefore, for a specified OPD, greater variation in the fringes indicates better measurement sensitivity. Here, we introduce and experimentally validate an interesting optical interference phenomenon that uses photons with a structured frequency-angular spectrum, which are generated from a spontaneous parametric down-conversion process in a nonlinear crystal. This interference phenomenon is manifested as interference fringes that vary much more rapidly with increasing OPD than the corresponding fringes for equal-inclination interference; the phenomenon is parameterised using an equivalent wavelength, which under our experimental conditions is 29.38 nm or about 1/27 of the real wavelength. This phenomenon not only enriches the knowledge with regard to optical interference but also offers promise for applications in interferometry.

arXiv:2110.14132•Light Science & Applications•Oct 26, 2021•8 citations

Experiments on intensity interferometry

Andreas Zmija, Peter Deiml, A. Zink +7 more

Verhandlungen der Deutschen Physikalischen Gesellschaft•Jan 1, 2018•0 citations
Quantum nonlinear interferometers (QNIs) can measure the infrared physical quantities of a sample by detecting visible photons. A QNI with Michelson geometry based on the spontaneous parametric down-conversion in a second-order nonlinear crystal is studied systematically. A simplified theoretical model of the QNI is presented. The interference visibility, coherence length, equal-inclination interference, and equal-thickness interference for the QNI are demonstrated theoretically and experimentally. As an application example of the QNI, the refractive index and the angle between two surfaces of a BBO crystal are measured using equal-inclination interference and equal-thickness interference.
Optical interference is not only a fundamental phenomenon that has enabled new theories of light to be derived but it has also been used in interferometry for the measurement of small displacements, refractive index changes, and surface irregularities. In a two-beam interferometer, variations in the interference fringes are used as a diagnostic for anything that causes the optical path difference (OPD) to change; therefore, for a specified OPD, greater variation in the fringes indicates better measurement sensitivity. Here, we introduce and experimentally validate an interesting optical interference phenomenon that uses photons with a structured frequency-angular spectrum, which are generated from a spontaneous parametric down-conversion process in a nonlinear crystal. This interference phenomenon is manifested as interference fringes that vary much more rapidly with increasing OPD than the corresponding fringes for equal-inclination interference; the phenomenon is parameterised using an equivalent wavelength, which under our experimental conditions is 29.38 nm or about 1/27 of the real wavelength. This phenomenon not only enriches the knowledge with regard to optical interference but also offers promise for applications in interferometry.