Asymmetric-Loss Equal-Born Test: proposal for a host laboratory and first-run equipment list
Robert James Cecil, Mark Trewick
Why this measurement is worth a bench: see section 2 of the proposal, "Why anyone should want to measure it". Contact: concursion.alebt@gmail.com. Two companion documents to the deposited paper, doi:10.5281/zenodo.22678044, and its pre-registration, osf.io/3h6yf. The question: does a 50/50 beam splitter transmit a single photon in exactly the same proportion as it transmits bright light? Standard linear optics says yes, exactly. The first run compares the two to one part in a thousand, with one source; only a calibrated attenuator changes between the bright phase and the single-photon phase. ALEBT_proposal_paper_v1_oct20.pdf: the proposal written for a host laboratory (the observable, the hypothesis, the error budget, the stages, the equipment and the open problems). ALEBT_equipment_list_v2_oct26.pdf: the first-run equipment list, with answers to the questions raised by groups we have written to (existing measurements, fibre-coupled detectors, differences between detectors). Version 2, 6 November 2026. Adds ALEBT_equipment_list_v3_nov06.pdf, which opens with a new section, "The one observable in which the hypothesis and linear optics differ, and its predicted size": zero exactly in linear optics; minus lambda* times (minus p ln p) under the hypothesis, with a fixed sign and a peak at p = 1/e; for the beam splitter alone a null at one part in 1,000 bounds lambda* below 0.003. It was written because two theorists who read the material did not find that difference stated in one place. The proposal (v1, 20 October) and the equipment list v2 (26 October, with its answers on existing measurements, fibre-coupled detectors and detector differences) are carried unchanged. The paper is now at version 2.1, doi:10.5281/zenodo.24014717, which quotes the Polyakov and Migdall (2007) comparison correctly as 0.14% plus or minus 0.14% at k = 1. Version 3, 6 November 2026. The proposal itself is now version 2 (ALEBT_proposal_paper_v2_nov06.pdf), replacing ALEBT_proposal_paper_v1_oct20.pdf, which remains in the earlier versions of this record. It adds section 2.0, "The one observable in which the hypothesis and linear optics differ, and its predicted size", and corrects the Polyakov and Migdall (2007) figure to 0.14% plus or minus 0.14% at k = 1 in two places. Nothing else in the proposal is changed. The two equipment lists (v2 of 26 October and v3 of 6 November) are carried unchanged.
•Oct 26, 2026•0 citations