Achieving the Second Doppler Cooling and Measuring the Temperature of Strontium Atoms

谢玉林 XIE Yu-lin, 卢本全 LU Ben-quan, 刘辉 LIU Hui, 王叶兵 WANG Ye-bing, 常宏 Chang Hong

Published Jan 1, 2015• 2 citations
Publisher
DOI
10.3788/asqo20152102.0136

Related papers

Measurement of the Temperature of Strontium Atoms by Doppler Cooling

Hong Chang

After the realization of Doppler cooling based on(5s2)1S0→(5s5p)1P1 in alkaline-earth metal strontium,the temperature of two isotopes of strontium which is 88Sr(bosons)and 87Sr(fermions) are measured using time of flight and expansion measurement.And the result of the two isotopes are~9 mK(88Sr) and~2 mK(87Sr).According the theory of Doppler cooling limited temperature,the experimental results are analyzed.This can be the well basis for the next step,1S0→3P1 narrow line cooling of strontium.

Acta Sinica Quantum Optica•Jan 1, 2010•0 citations

Novel cooling schemes for atomic strontium

Benjamin Bloom, Sebastian Blatt, Travis Nicholson +5 more

APS•Mar 1, 2010•0 citations

SIMULTANEOUS DUAL LASER STABILIZATION FOR STRONTIUM ATOM INTERFEROMETRY

Spakowski, Matthew D.

The use of strontium in an atom interferometer presents the opportunity to perform detailed measurements of gravitational fields, rotation rates, and clock transitions as well as other natural phenomena. Strontium can be particularly effective in atom interferometry experiments for two reasons. The first is that the intrinsic magnetic properties of strontium result in less sensitivity of the transition frequencies to magnetic noise, allowing for better measurements. Second, strontium atoms can be cooled to a lower temperature just through ordinary Doppler cooling than other atoms typically used in interferometry (e.g., rubidium). A lower temperature means less initial kinetic energy and hence lower spatial dispersion over the course of an experiment. A magneto-optical trap consisting of two primary cooling lasers and two repump lasers cools and confines strontium atoms for use in the interferometer. This thesis focuses on the repump lasers and includes the design and performance of the optical system that frequency stabilizes each laser. The system demonstrated the ability to simultaneously frequency lock the two repump lasers to the degree necessary to form a strontium magneto-optical trap.

•Sep 1, 2022•0 citations

Laser cooling and trapping of strontium atoms for experiments towards precision measurements and frequency metrology

Chetan Vishwakarma

•Dec 1, 2020•0 citations

Recent Experiments in Ultracold Strontium

Sarah Nagel, Y. N. Martinez, Pascal G. Mickelson +1 more

Bulletin of the American Physical Society•May 19, 2006•0 citations

Narrow-line Doppler cooling of strontium to the recoil limit

Kurt R. Vogel, T. Dinneen, Alan C. Gallagher +1 more

Experimental results on narrow line cooling of strontium atoms are presented. Doppler cooling is performed on the /sup 1/S/sub 0/-/sup 3/P/sub 1/ intercombination transition at 689 nm resulting in temperatures near the recoil limit in a one-dimensional (1-D) optical molasses. Frequency chirp cooling is successfully demonstrated as a means of expanding the cooling range.

IEEE Transactions on Instrumentation and Measurement•Apr 1, 1999•49 citations
After the realization of Doppler cooling based on(5s2)1S0→(5s5p)1P1 in alkaline-earth metal strontium,the temperature of two isotopes of strontium which is 88Sr(bosons)and 87Sr(fermions) are measured using time of flight and expansion measurement.And the result of the two isotopes are~9 mK(88Sr) and~2 mK(87Sr).According the theory of Doppler cooling limited temperature,the experimental results are analyzed.This can be the well basis for the next step,1S0→3P1 narrow line cooling of strontium.
The use of strontium in an atom interferometer presents the opportunity to perform detailed measurements of gravitational fields, rotation rates, and clock transitions as well as other natural phenomena. Strontium can be particularly effective in atom interferometry experiments for two reasons. The first is that the intrinsic magnetic properties of strontium result in less sensitivity of the transition frequencies to magnetic noise, allowing for better measurements. Second, strontium atoms can be cooled to a lower temperature just through ordinary Doppler cooling than other atoms typically used in interferometry (e.g., rubidium). A lower temperature means less initial kinetic energy and hence lower spatial dispersion over the course of an experiment. A magneto-optical trap consisting of two primary cooling lasers and two repump lasers cools and confines strontium atoms for use in the interferometer. This thesis focuses on the repump lasers and includes the design and performance of the optical system that frequency stabilizes each laser. The system demonstrated the ability to simultaneously frequency lock the two repump lasers to the degree necessary to form a strontium magneto-optical trap.