Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)

Chip-scale atomic devices based on microfabricated alkali vapor cells

John E. Kitching

Published Jun 1, 2007• 0 citations
Publisher
DOI
10.1109/cleoe-iqec.2007.4387076

Related papers

Fabrication and Study of Micro Alkali-Metal Vapor Cell Applied to Chip Scale Atomic Clock

汤跃 Tang Yue, 任子明 Ren Ziming, 李云超 Li Yunchao +3 more

Laser & Optoelectronics Progress•Jan 1, 2018•1 citation

The Microfabricated Alkali Vapor Cell with High Hermeticity for Chip-Scale Atomic Clock

Shuo Jia, Zhiyuan Jiang, Binbin Jiao +4 more

Herein, a microfabricated millimeter-level vapor alkali cell with a high hermeticity is fabricated through a wet etching and single-chip anodic bonding process. The vapor cell, containing Rb and N2, was investigated in a coherent population trapping (CPT) setup for the application of a chip-scale atomic clock (CSAC). The contrast of CPT resonance is up to 1.1% within the only 1 mm length of light interacting with atom. The effects of some critical external parameters on the CPT resonance, such as laser intensity, cell temperature, and buffer gas pressure, are thoroughly studied and optimized. The improved microfabricated vapor cell also exhibited great potential for other chip-scale atomic devices.

Applied Sciences•Jan 3, 2022•21 citations

Chip-Scale AtomicDevices BasedonMicrofabricated Alkali VaporCells

John E. Kitching, Svenja A. Knappe, John Moreland +6 more

•Jan 1, 2004•0 citations

Chip scale atomic devices

Svenja A. Knappe, Peter D. D. Schwindt, Vladislav P. Gerginov +9 more

•Mar 13, 2007•0 citations

Chip-Scale Atomic Devices Based on Microfabricated Alkali Vapor Cells

John E. Kitching, Svenja A. Knappe, John Moreland +8 more

We describe recent progress in the development of millimeter-scale instruments based on alkali atom vapor cells implemented with microfabrication techniques. Because of their small size and correspondingly low power requirements, these "chip-scale" atomic clocks and magnetometers have the potential to bring atomically precise instrumentation to portable, battery-operated systems such as GPS receivers, remote sensors and wireless communication devices. In addition, wafer-level processing and assembly potentially allows for very low cost per instrument if high volumes are produced.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 1, 2007•1 citation

Improvement of Sensitivity by Using Microfabricated Spherical Alkali Vapor Cells for Chip-Scale Atomic Magnetometers

Yu Ji, Jintang Shang, Qi Gan +2 more

The designs of microfabricated alkali vapor cells play an important role when the atomic magnetometers are developing toward on-chip integration. This paper presents microfabricated spherical alkali vapor cells with improved sensitivity for chip-scale atomic magnetometers. A microfabricated spherical rubidium vapor cell and a traditional microfabricated planar rubidium vapor cell are designed for comparison, which are of the same volume and interconnected by a microchannel to acquire equal inner buffer gas pressure. In chip-scale spin-exchange relaxation-free (SERF) atomic magnetometers, the rubidium polarization lifetimes of three pairs of spherical and planar vapor cells at different buffer gas pressures of 0.35, 0.73, and 2.00 amg are measured, respectively. The sensitivity of SERF atomic magnetometers using the vapor cells at a 0.35-amg buffer gas pressure is also measured. The results show that the transverse polarization lifetime of the spherical vapor cell is 2.46, 1.44, and 1.05 times that of the planar one at 0.35-, 0.73-, and 2.00-amg buffer gas pressures, respectively. Combining the improved polarization lifetime and increased optical path length, chip-scale SERF atomic magnetometer using the microspherical vapor cell has the sensitivity of 60 fT/Hz1/2from 5 to 15 Hz, while that based on the planar one is demonstrated with the sensitivity of 400 fT/Hz1/2from 5 to 15 Hz.

IEEE Transactions on Components Packaging and Manufacturing Technology•Sep 3, 2018•23 citations
Herein, a microfabricated millimeter-level vapor alkali cell with a high hermeticity is fabricated through a wet etching and single-chip anodic bonding process. The vapor cell, containing Rb and N2, was investigated in a coherent population trapping (CPT) setup for the application of a chip-scale atomic clock (CSAC). The contrast of CPT resonance is up to 1.1% within the only 1 mm length of light interacting with atom. The effects of some critical external parameters on the CPT resonance, such as laser intensity, cell temperature, and buffer gas pressure, are thoroughly studied and optimized. The improved microfabricated vapor cell also exhibited great potential for other chip-scale atomic devices.
We describe recent progress in the development of millimeter-scale instruments based on alkali atom vapor cells implemented with microfabrication techniques. Because of their small size and correspondingly low power requirements, these "chip-scale" atomic clocks and magnetometers have the potential to bring atomically precise instrumentation to portable, battery-operated systems such as GPS receivers, remote sensors and wireless communication devices. In addition, wafer-level processing and assembly potentially allows for very low cost per instrument if high volumes are produced.
The designs of microfabricated alkali vapor cells play an important role when the atomic magnetometers are developing toward on-chip integration. This paper presents microfabricated spherical alkali vapor cells with improved sensitivity for chip-scale atomic magnetometers. A microfabricated spherical rubidium vapor cell and a traditional microfabricated planar rubidium vapor cell are designed for comparison, which are of the same volume and interconnected by a microchannel to acquire equal inner buffer gas pressure. In chip-scale spin-exchange relaxation-free (SERF) atomic magnetometers, the rubidium polarization lifetimes of three pairs of spherical and planar vapor cells at different buffer gas pressures of 0.35, 0.73, and 2.00 amg are measured, respectively. The sensitivity of SERF atomic magnetometers using the vapor cells at a 0.35-amg buffer gas pressure is also measured. The results show that the transverse polarization lifetime of the spherical vapor cell is 2.46, 1.44, and 1.05 times that of the planar one at 0.35-, 0.73-, and 2.00-amg buffer gas pressures, respectively. Combining the improved polarization lifetime and increased optical path length, chip-scale SERF atomic magnetometer using the microspherical vapor cell has the sensitivity of 60 fT/Hz1/2from 5 to 15 Hz, while that based on the planar one is demonstrated with the sensitivity of 400 fT/Hz1/2from 5 to 15 Hz.