Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Research in Optical Sciences

Ghost imaging by intense multimode twin beam

Alessia Allevi, Maria Bondani

Published Jan 1, 2012• 3 citations
Publisher

Abstract

We present the first experimental implementation of the ghost-imaging protocol based on an intense multimode spontaneous parametric down-conversion process. Temporal and spatial properties of the quantum field used in the protocol are also discussed.
DOI
10.1364/qim.2012.qt4b.2

Related papers

Temporal ghost imaging with twin photons

Séverine Denis, Paul‐Antoine Moreau, F. Devaux +1 more

Abstract We use twin photons generated by spontaneous parametric down conversion to perform temporal ghost imaging of a single time signal. The retrieval of a binary signal containing eight bits is performed with an error rate below 1%.

arXiv:1612.05723•Journal of Optics•Feb 9, 2017•35 citations

Ghost imaging with intense entangled fields

Alessandra Andreoni, E. Puddu, Ivo Pietro Degiovanni +2 more

We implement a frequency degenerate seeded downconversion process in which the seed field is a spatially multimode chaotic field. The two output fields are quantum correlated in space and intensity and maintain the same spatial and temporal structure as the seeding field and thus represent two almost twin multimode fields that can be used for ghost imaging applications.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Sep 11, 2007•0 citations

Ghost imaging by intense multimode twin beam

Maria Bondani, Alessia Allevi, Alessandra Andreoni

The European Physical Journal Special Topics•Apr 1, 2012•17 citations

Temporal ghost imaging with photon pairs

Séverine Denis, Paul‐Antoine Moreau, F. Devaux +1 more

We present an experiment of temporal ghost imaging based on the spatial properties of twin photons. The retrieval of a binary time signal of 8 bits is performed with an error rate of 0.70%.

Quantum Information and Measurement (QIM)•Jan 1, 2017•0 citations

Multimode thermal-seeded parametric down-conversion: Entanglement and ghost imaging

Ivo Pietro Degiovanni, Maria Bondani, E. Puddu +2 more

The European Physical Journal Special Topics•Jun 17, 2008•0 citations

Accessible “Spooky Action at a Distance”

Tate Thomas, Dulcinea Cabreda

“Ghost” imaging is a process utilizing entangled photon pairs, by which an image is produced indirectly, using photons that have never interacted with the object being imaged. We can do this by taking advantage of correlations inherent in Spontaneous Parametric Down Conversion (SPDC), which is used to produce these entangled photon pairs. SPDC is a classically forbidden process in which a photon of a high frequency is converted into a pair of photons. The change in frequency makes this a nonlinear process. Processes like absorption, reflection, refraction, and polarization are linear processes. These can affect the properties of a light field but cannot change the frequency. SPDC allows us to produce a pair of correlated photons. By utilizing a coincidence-counter, we will be able to measure photon pairs from the source beam arriving within a narrow time interval. With this restriction, we can limit our attention to these correlated photons. One of these photons, which does interact with the object to be imaged, is used to turn on a “camera” detecting the other photon. It is the correlations between these photons that allow for ghost imaging, the reconstruction of the image of an object, even though the object never interacts directly with those single photons that are going to our camera.

•Apr 11, 2026•0 citations
“Ghost” imaging is a process utilizing entangled photon pairs, by which an image is produced indirectly, using photons that have never interacted with the object being imaged. We can do this by taking advantage of correlations inherent in Spontaneous Parametric Down Conversion (SPDC), which is used to produce these entangled photon pairs. SPDC is a classically forbidden process in which a photon of a high frequency is converted into a pair of photons. The change in frequency makes this a nonlinear process. Processes like absorption, reflection, refraction, and polarization are linear processes. These can affect the properties of a light field but cannot change the frequency. SPDC allows us to produce a pair of correlated photons. By utilizing a coincidence-counter, we will be able to measure photon pairs from the source beam arriving within a narrow time interval. With this restriction, we can limit our attention to these correlated photons. One of these photons, which does interact with the object to be imaged, is used to turn on a “camera” detecting the other photon. It is the correlations between these photons that allow for ghost imaging, the reconstruction of the image of an object, even though the object never interacts directly with those single photons that are going to our camera.