Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Springer eBooks

Exact Trapping State Dynamics for the 85Rb Atom Micromaser at Very High Q and/or Very Low T

R. Bullough, Amitabh Joshi, A. Kremid, N. Nayak, B. V. Thompson

Published Jan 1, 1996• 0 citations
Publisher
DOI
10.1007/978-1-4757-9742-8_43

Related papers

Trapping states and micromaser dynamics by a quantum-trajectory approach

Federico Casagrande, Maria Lisa Garavaglia, ALFREDO LULLI

Optics Communications•Jun 1, 1998•13 citations

Exact trapping state dynamics for the 85Rb atom micromaser at very high Q and/or very low T

Amitabh Joshi, A. Kremid, N. Nayak +2 more

Matrix continued fraction methods pioneered previously [1–3] are used to solve essentially exactly the dynamics of the one 85Rb atom micromaser. Ranges of cavity Q values, of average atomic input rates R = T p −1 and of atomic interaction times t int are studied with the principal aim of minimizing the cavity field variance v. As expected for T p ≳ 200t int the system does evolve to a steady state with v < 1 and sub-Poissonian photon statistics. But even Q = 5 × 1010 and temperature T = 0·070 K are apparently insufficient conditions for avoiding evolution to a steady state with v < 0 when t int = 1·54/(44 kHz) unless T p is also substantially reduced. Only in this way is actual trapping state dynamics obtained for this value of t int, while no example is found where the system evolves to v = 0 and a single Fock state is produced. The field variance v considered alone is not a good diagnostic for observing such trapping state dynamics and more information will be needed in order to describe adequately the cavity field.

Journal of Modern Optics•May 1, 1996•4 citations

Exact trapping state dynamics for the 85 Rb atom micromaser at very high Q and/or very low T

Amitabh Joshi, A. Kremid, N. Nayak +2 more

We have used matrix continued fraction methods pioneered previously, to solve essentially exactly for the dynamics of the one 85Rb atom micromaser. A range of cavity Q values and of average atomic input rates R equals Tp-1 and of atomic interaction times tint is studied. For Tp approximately greater than 200tint the system does evolve to a steady state. And even Q equals 5 multiplied by 1010 and temperature T equals 0.070 degrees K are apparently insufficient to avoid evolution to a steady state with finite variance of the cavity field when tint equals 1.54/44 kHz unless Tp is also substantially reduced. Only in this way are actual trapping state dynamics obtained. The field variance v is not a good diagnostic for observing such trapping state dynamics.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•May 6, 1996•2 citations

Micromaser Trapping States By Quantum-trajectory Simulations

Federico Casagrande, Maria Lisa Garavaglia, ALFREDO LULLI

European Quantum Electronics Conference (EQEC)•Aug 24, 2005•0 citations

Trapping and photon number states in a two-photon micromaser

Moorad Alexanian, S. Bose, Lee Chow

Journal of Luminescence•Feb 1, 1998•4 citations

EXACT CALCULATIONS FOR ONE PHOTON MICROMASER WITH COHERENT INPUTS I

A. Kremid

We report a numerical simulation of the action of the one 85 Rb atom micromaser which shows that the micromaser field evolves towards a steady state equilibrium when the condition that Tp t int satisfies. In this steady state regime the cavity field reaches a steady state after a sufficient number of atoms have passed through the cavity. The cavity temperature T and the cavity quality factor Q can produce a quantitive change when one of them or the two are changed but they are not responsible for the qualitative changes in the micromaser field. Evidently the only responsible parameter for these qualitative changes is the repetition time T p namely if T p t int then the micromaser field evolution is towards a steady state equilibrium. In contrast when T p reduced to the order of t int then the micromaser field evolution is controlled by the trapping state dynamics – no steady state is apparent in this case. The first going-up trapping state at n=3 plays a significant role in the early dynamics of the micromaser field. Moreover the state of the field ultimately evolves towards a mixed state rather than a pure state.

EPH - International Journal of Applied Science•Dec 27, 2021•1 citation
Matrix continued fraction methods pioneered previously [1–3] are used to solve essentially exactly the dynamics of the one 85Rb atom micromaser. Ranges of cavity Q values, of average atomic input rates R = T p −1 and of atomic interaction times t int are studied with the principal aim of minimizing the cavity field variance v. As expected for T p ≳ 200t int the system does evolve to a steady state with v < 1 and sub-Poissonian photon statistics. But even Q = 5 × 1010 and temperature T = 0·070 K are apparently insufficient conditions for avoiding evolution to a steady state with v < 0 when t int = 1·54/(44 kHz) unless T p is also substantially reduced. Only in this way is actual trapping state dynamics obtained for this value of t int, while no example is found where the system evolves to v = 0 and a single Fock state is produced. The field variance v considered alone is not a good diagnostic for observing such trapping state dynamics and more information will be needed in order to describe adequately the cavity field.
We have used matrix continued fraction methods pioneered previously, to solve essentially exactly for the dynamics of the one 85Rb atom micromaser. A range of cavity Q values and of average atomic input rates R equals Tp-1 and of atomic interaction times tint is studied. For Tp approximately greater than 200tint the system does evolve to a steady state. And even Q equals 5 multiplied by 1010 and temperature T equals 0.070 degrees K are apparently insufficient to avoid evolution to a steady state with finite variance of the cavity field when tint equals 1.54/44 kHz unless Tp is also substantially reduced. Only in this way are actual trapping state dynamics obtained. The field variance v is not a good diagnostic for observing such trapping state dynamics.
We report a numerical simulation of the action of the one 85 Rb atom micromaser which shows that the micromaser field evolves towards a steady state equilibrium when the condition that Tp t int satisfies. In this steady state regime the cavity field reaches a steady state after a sufficient number of atoms have passed through the cavity. The cavity temperature T and the cavity quality factor Q can produce a quantitive change when one of them or the two are changed but they are not responsible for the qualitative changes in the micromaser field. Evidently the only responsible parameter for these qualitative changes is the repetition time T p namely if T p t int then the micromaser field evolution is towards a steady state equilibrium. In contrast when T p reduced to the order of t int then the micromaser field evolution is controlled by the trapping state dynamics – no steady state is apparent in this case. The first going-up trapping state at n=3 plays a significant role in the early dynamics of the micromaser field. Moreover the state of the field ultimately evolves towards a mixed state rather than a pure state.