Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Quantum Electronics

Comparison of field shifts in an atomic clock based on the effect of coherent population trapping in 87Rb atoms under modulation of laser pump current at frequencies of 3.4 and 6.8 GHz

S M Ignatovich, Mikhail N Skvortsov, I. S. Mesenzova, L.N. Kvashnin, V. I. Vishnyakov, Denis V. Brazhnikov, Sergei N Bagayev

Published Mar 30, 2022• 1 citation
Publisher

Abstract

Abstract Experimental parameters of the resonance of coherent population trapping (CTP) on D1 line in 87Rb and light shifts are compared under modulation of the laser pump current at frequencies of 3.4 and 6.8 GHz. Reproducibility of the parameters of a laser with a vertical cavity needed for long-term stability of an atomic clock is considered. The instabilities of atomic CPT-clock obtained for 1 s are 1.2 × 10−11 and 3 × 10−12 for frequencies of 3.4 GHz and 6.8 GHz, respectively.

DOI
10.1070/qel18023

Related papers

Coherent Population Trapping Resonance Parameters and Field Shifts during the Detection of Signals from Different Cross-Sectional Areas of the Interaction of Laser Radiation with Atoms

S M Ignatovich, Mikhail N Skvortsov, I. S. Mesenzova +4 more

Abstract The results of an experimental comparison of the parameters of the coherent population trapping (CPT) resonance for the 87Rb D1 line and the light shifts during the detection of signals from different cross-sectional areas of the interaction of laser radiation with atoms are presented. A method is proposed to search for zero-light-shift operating conditions and their automatic stabilization, which would improve the long-term stability of CPT-resonance-based microwave frequency standards.

Journal of Experimental and Theoretical Physics•Aug 1, 2023•0 citations

Properties of Rb CPT Atomic Clock at Subharmonic Microwave Modulation Frequencies

Daba A. Radnatarov, Sergey M Kobtsev, Valeriy Andryushkov +3 more

This letter presents for the first time a systematic study of an atomic frequency standard based on coherent population trapping (CPT) effect in87Rb vapour optically pumped with a multifrequency laser radiation formed with sidebands of a single-frequency laser whose injection current is modulated at a subharmonic frequency (1/2-1/6) relative to the frequency of hyperfine ground state splitting. Measured are the CPT resonance parameters and the atomic clock short-term stability at different subharmonic frequencies of microwave modulation. The possibility of CPT resonance light shift suppression is experimentally demonstrated at modulation frequencies between 1/3 and 1/5 of the resonant frequency for continuous wave optical pumping of the87Rb vapour D1 line. Analyzed are the capabilities and potential of reduced energy consumption of atomic clocks when CPT resonance in rubidium vapour is excited at subharmonic modulation frequencies.

IEEE photonics journal•Jun 26, 2019•2 citations

Performance of a prototype atomic clock based on lin‖lin coherent population trapping resonances in Rb atomic vapor

Eugeniy E. Mikhailov, Travis Horrom, Nathan Belcher +1 more

We report on the performance of the first table-top prototype atomic clock based on coherent population trapping (CPT) resonances with parallel linearly polarized optical fields (lin‖lin configuration). Our apparatus uses a vertical-cavity surface-emitting laser (VCSEL) tuned to the D1 line of 87Rb with the current modulation at the 87Rb hyperfine frequency. We demonstrate cancellation of the first-order light shift by the proper choice of rf modulation power and further improve our prototype clock stability by optimizing the parameters of the microwave lock loop. Operating in these optimal conditions, we measured a short-term fractional frequency stability (Allan deviation) 2×10−11τ−1/2 for observation times 1 s ≤ τ ≤ 20 s. This value is limited by large VCSEL phase noise and environmental temperature fluctuation. Further improvements in frequency stability should be possible with an apparatus designed as a dedicated lin‖lin CPT resonance clock with environmental impacts minimized.

arXiv:0910.5881•Journal of the Optical Society of America B•Feb 3, 2010•55 citations

Passive atomic frequency standard based on coherent population trapping in ^87Rb using injection-locked lasers

Han Seb Moon, Sang Eon Park, Young‐Ho Park +2 more

We present a microwave frequency standard based on coherent population trapping (CPT) in the 87Rb D1 line. The CPT spectrum is obtained using two Raman lasers with a 6.8 GHz frequency offset by injection locking of a master laser to a slave laser. We have constructed an atomic clock employing a 5 cm long Rb vapor cell confined with 6.67 kPa neon buffer gas at 70 °C. Using this system, we improve the CPT contrast through the elimination of undesired off-resonant fields created by the direct modulation method. We measured the frequency shift of the CPT signal as a function of the temperature of the Rb cell and estimated it to be approximately 1.3 ×10−9/K. The frequency of a 10 MHz crystal oscillator has been stabilized to the CPT spectrum between the two ground states in 87Rb. The relative frequency stability is approximately 2.3×10−12 for an average time of 68 s.

Journal of the Optical Society of America B•Nov 1, 2006•23 citations

Atomic clock based on a coherent population trapping resonance in87Rb with improved high-frequency modulation parameters

Sergey Khripunov, Daba A. Radnatarov, Sergey M Kobtsev

This work reports for the first time development and experimental study of a laboratory prototype of an atomic clock with stability of 2×10–11τ –1/2 (Allan deviation) over time 1 s < τ < 1000 s (7×10–13 over 1000 s) on the basis of a coherent population trapping (CPT) resonance in 87Rb in a compact spherical cell having 1.3-cm diameter and without any buffer gas. Demonstrated are dependencies of the width of the studied CPT resonance upon the amplitude and modulation frequency of optical frequency difference (3.417 GHz) of a bichromatic circularly polarised pump field. For the first time, a considerable non-linearity was discovered in the dependence upon the reference difference frequency of the spectral position of the CPT resonance when the modulation frequency of the optical frequency difference is varied within a broad range.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Mar 10, 2015•21 citations

Limitations of Long-Term Stability in a Coherent Population Trapping Cs Clock

Olga Kozlova, Jean-Marie Danet, Stéphane Guérandel +1 more

Vapor cell atomic clocks exhibit reduced frequency stability for averaging time between about one hundred and a few thousand seconds. Here we report a study on the impact of the main parameters on the mid-to-long term instability of a buffer-gas vapor cell Cs clock, based on coherent population trapping (CPT). The CPT signal is observed on the Cs D1 line transmission, using a double Λ scheme and a Ramsey interrogation technique. The effects on the clock frequency of the magnetic field, the cell temperature, and the laser intensities are reported. We show in particular that the laser intensity shift is temperature dependent. Along with the laser intensity ratio and laser polarization properties, this is one of the most important parameters.

arXiv:1311.1991•IEEE Transactions on Instrumentation and Measurement•Jan 31, 2014•63 citations
Abstract Experimental parameters of the resonance of coherent population trapping (CTP) on D1 line in 87Rb and light shifts are compared under modulation of the laser pump current at frequencies of 3.4 and 6.8 GHz. Reproducibility of the parameters of a laser with a vertical cavity needed for long-term stability of an atomic clock is considered. The instabilities of atomic CPT-clock obtained for 1 s are 1.2 × 10−11 and 3 × 10−12 for frequencies of 3.4 GHz and 6.8 GHz, respectively.
Abstract The results of an experimental comparison of the parameters of the coherent population trapping (CPT) resonance for the 87Rb D1 line and the light shifts during the detection of signals from different cross-sectional areas of the interaction of laser radiation with atoms are presented. A method is proposed to search for zero-light-shift operating conditions and their automatic stabilization, which would improve the long-term stability of CPT-resonance-based microwave frequency standards.
This letter presents for the first time a systematic study of an atomic frequency standard based on coherent population trapping (CPT) effect in87Rb vapour optically pumped with a multifrequency laser radiation formed with sidebands of a single-frequency laser whose injection current is modulated at a subharmonic frequency (1/2-1/6) relative to the frequency of hyperfine ground state splitting. Measured are the CPT resonance parameters and the atomic clock short-term stability at different subharmonic frequencies of microwave modulation. The possibility of CPT resonance light shift suppression is experimentally demonstrated at modulation frequencies between 1/3 and 1/5 of the resonant frequency for continuous wave optical pumping of the87Rb vapour D1 line. Analyzed are the capabilities and potential of reduced energy consumption of atomic clocks when CPT resonance in rubidium vapour is excited at subharmonic modulation frequencies.
We report on the performance of the first table-top prototype atomic clock based on coherent population trapping (CPT) resonances with parallel linearly polarized optical fields (lin‖lin configuration). Our apparatus uses a vertical-cavity surface-emitting laser (VCSEL) tuned to the D1 line of 87Rb with the current modulation at the 87Rb hyperfine frequency. We demonstrate cancellation of the first-order light shift by the proper choice of rf modulation power and further improve our prototype clock stability by optimizing the parameters of the microwave lock loop. Operating in these optimal conditions, we measured a short-term fractional frequency stability (Allan deviation) 2×10−11τ−1/2 for observation times 1 s ≤ τ ≤ 20 s. This value is limited by large VCSEL phase noise and environmental temperature fluctuation. Further improvements in frequency stability should be possible with an apparatus designed as a dedicated lin‖lin CPT resonance clock with environmental impacts minimized.
We present a microwave frequency standard based on coherent population trapping (CPT) in the 87Rb D1 line. The CPT spectrum is obtained using two Raman lasers with a 6.8 GHz frequency offset by injection locking of a master laser to a slave laser. We have constructed an atomic clock employing a 5 cm long Rb vapor cell confined with 6.67 kPa neon buffer gas at 70 °C. Using this system, we improve the CPT contrast through the elimination of undesired off-resonant fields created by the direct modulation method. We measured the frequency shift of the CPT signal as a function of the temperature of the Rb cell and estimated it to be approximately 1.3 ×10−9/K. The frequency of a 10 MHz crystal oscillator has been stabilized to the CPT spectrum between the two ground states in 87Rb. The relative frequency stability is approximately 2.3×10−12 for an average time of 68 s.
This work reports for the first time development and experimental study of a laboratory prototype of an atomic clock with stability of 2×10–11τ –1/2 (Allan deviation) over time 1 s < τ < 1000 s (7×10–13 over 1000 s) on the basis of a coherent population trapping (CPT) resonance in 87Rb in a compact spherical cell having 1.3-cm diameter and without any buffer gas. Demonstrated are dependencies of the width of the studied CPT resonance upon the amplitude and modulation frequency of optical frequency difference (3.417 GHz) of a bichromatic circularly polarised pump field. For the first time, a considerable non-linearity was discovered in the dependence upon the reference difference frequency of the spectral position of the CPT resonance when the modulation frequency of the optical frequency difference is varied within a broad range.
Vapor cell atomic clocks exhibit reduced frequency stability for averaging time between about one hundred and a few thousand seconds. Here we report a study on the impact of the main parameters on the mid-to-long term instability of a buffer-gas vapor cell Cs clock, based on coherent population trapping (CPT). The CPT signal is observed on the Cs D1 line transmission, using a double Λ scheme and a Ramsey interrogation technique. The effects on the clock frequency of the magnetic field, the cell temperature, and the laser intensities are reported. We show in particular that the laser intensity shift is temperature dependent. Along with the laser intensity ratio and laser polarization properties, this is one of the most important parameters.