Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optical and Quantum Sensing and Precision Metrology II

Quantum advantage of seeded, squeezed light in absorption and gain measurement

G. S. Agarwal

Published Mar 9, 2022• 0 citations
Publisher

Abstract

We use bright squeezed light to demonstrate that direct absorption and gain measurements can be performed with sensitivity beyond the shot-noise limit without requiring homodyne/lock-in, or logic coincidence detection schemes. Previously we reported more than 1 dB quantum advantage [ 3 dB when corrected losses in optical paths] for the measurement sensitivity at faint absorption levels. We present our detailed results on definite quantum advantage of about 3dB in measurements of Brillouin gain.

DOI
10.1117/12.2616876

Related papers

Quantum Advantage with Seeded Squeezed Light for Absorption Measurement

Fu Li, Tian Li, Marlan O. Scully +1 more

Absorption measurement is an exceptionally versatile tool for many applications in science and engineering. For absorption measurements using laser beams of light, the sensitivity is theoretically limited by the shot noise due to the fundamental Poisson distribution of the photon number in laser radiation. In practice, the shot-noise limit can only be achieved when all other sources of noise are eliminated. Here, we use seeded squeezed light to demonstrate that direct-absorption measurements can be performed with a sensitivity beyond the shot-noise limit. We present a practically realizable scheme, where intensity-squeezed beams are generated by a seeded four-wave mixing process in an atomic rubidium-vapor cell. More than 1.2 dB quantum advantage for the measurement sensitivity is obtained at faint absorption levels ($\ensuremath{\le}10\mathrm{%}$). We also present a detailed theoretical analysis to show that the observed quantum advantage when corrected for optical loss would be equivalent to 3 dB. Our experiment demonstrates a direct sub-shot-noise measurement of absorption that requires neither homodyne or lock-in nor logic coincidence-detection schemes. It is therefore very applicable in many circumstances where sub-shot-noise-level absorption measurements are highly desirable.

arXiv:2007.05583•Physical Review Applied•Apr 20, 2021•33 citations

Quantum metrology of absorption and gain parameters using two-mode bright squeezed light

Mrunal Kamble, Jiaxuan Wang, G. S. Agarwal

Absorption and gain processes are fundamental to any light-matter interaction and a precise measurement of these parameters is important for various scientific and technological applications. Quantum probes, specifically the squeezed states, have proved very successful, particularly in the applications that deal with phase shift and force measurements. In this paper, we focus on improving the sensitivity of the estimation of the photon-loss coefficient of a weakly absorbing medium as well as the estimation of the gain parameter using a two-mode bright squeezed state. The generation of this state combines the advantage of a coherent beam for its large photon number with the quantum properties of the two-mode squeezing operation in an optical parametric amplifier. We present two measurement schemes: balanced photodetection and time-reversed metrology, both utilizing two-mode bright squeezed light. The maximum quantum advantage we can achieve using two-mode bright squeezed light is 3.7 times for the absorption parameter $\ensuremath{\alpha}=0.05$ and 8.4 times for $\ensuremath{\alpha}=0.01$ as compared to using only the coherent state. Similarly, the maximum quantum advantage for the estimation of optical gain is found around 2.95 times for the gain coefficient $G=1.05$ and around 6.35 times for $G=1.01$. We discuss the significance of using one measurement scheme over the other under different squeezing conditions. We compare our results with the Cram\'er-Rao bound for a two-mode bright squeezed state to assess the quality of the proposed methodologies.

arXiv:2404.00871•Physical Review A•May 16, 2024•17 citations

A Bright Squeezed Light Source for Quantum Sensing

Wenhai Yang, Wenting Diao, Chunxiao Cai +8 more

The use of optical sensing for in vivo applications is compelling, since it offers the advantages of non-invasiveness, non-ionizing radiation, and real-time monitoring. However, the signal-to-noise ratio (SNR) of the optical signal deteriorates dramatically as the biological tissue increases. Although increasing laser power can improve the SNR, intense lasers can severely disturb biological processes and viability. Quantum sensing with bright squeezed light can make the measurement sensitivity break through the quantum noise limit under weak laser conditions. A bright squeezed light source is demonstrated to avoid the deterioration of SNR and biological damage, which integrates an external cavity frequency-doubled laser, a semi-monolithic standing cavity with periodically poled titanyl phosphate (PPKTP), and a balanced homodyne detector (BHD) assembled on a dedicated breadboard. With the rational design of the mechanical elements, the optical layout, and the feedback control equipment, a maximum non-classical noise reduction of −10.7 ± 0.2 dB is observed. The average squeeze of −10 ± 0.2 dB in continuous operation for 60 min is demonstrated. Finally, the intracavity loss of degenerate optical parametric amplifier (DOPA) and the initial bright squeezed light can be calculated to be 0.0021 and −15.5 ± 0.2 dB, respectively. Through the above experimental and theoretical analysis, the direction of improving bright squeeze level is pointed out.

Chemosensors•Dec 25, 2022•14 citations

Bright seeded and quasi-continuous two-mode intensity squeezing in commercial fiber

Elad Zehavi, Alon Bernstein, Michal Natan +4 more

Squeezed states of light enable optical measurements with sensitivity beyond the shot noise limit of detection with classical light. Optical fibers represent a major potential platform for quantum squeezed sensing due to the extremely low loss and perfect single-spatial-mode operation. In this work, we demonstrate two-mode intensity squeezing directly within a commercially available optical fiber, based on a four-wave mixing process. The setup operates in a quasi-continuous-wave mode using 15 ns long pulses and relies on standard laser diode sources, telecommunication electro-optic modulators, and simple photo-detectors. The process is seeded by a coherent signal input, generating bright squeezed output states. Absolute noise reduction by 4 dB below the classical shot-noise limit is detected directly with no post-processing, for output signal and idler pulses of 2.4 × 10 6 photons in average. The results are applicable to quantum interferometry over fiber using simple, readily available components.

Optics Express•Jul 9, 2026•0 citations

Precision measurement beyond the shot-noise limit

Min Xiao, Ling-An Wu, H. J. Kimble

Improvements in precision beyond the limit set by the vacuum state or zero-point fluctuations of the field are reported for two optical experiments. Both experiments employ the squeezed light from an optical parametric oscillator to reduce the level of fluctuations in one of two quadrature phase amplitudes below the shot-noise level (SNL). The first experiment follows the work of Caves1 on precision interferometry with squeezed states. An increase in signal-to-noise of 2.5 dB relative to the SNL is demonstrated for the detection of phase modulation in a Mach-Zehnder interferometer. In the second experiment amplitude modulation is encoded on a weak signal beam with an acoustooptic modulator. For the case of a squeezed signal beam compared with a beam in a coherent state, an improvement in sensitivity of 2.5 dB is achieved for the detection of amplitude changes of the field. The observed increases in sensitivity in both experiments are currently limited by simple linear losses in propagation and detection and not by the degree of available squeezing.

Annual Meeting Optical Society of America•Jan 1, 1987•3 citations

Quantum Metrology with Bright Squeezed Light

George S. Atkinson

Squeezed light enables measurements with sensitivity beyond the quantum noise limit (QNL) for optical techniques such as spectroscopy, gravitational wave detection, magnetometry, and imaging. Precision of a measurement---as quantified by the variance of repeated estimates---has also been enhanced beyond the QNL using squeezed light. However, sub-QNL sensitivity is not sufficient to achieve sub-QNL precision. Furthermore, demonstrations of sub-QNL precision in estimating transmission have been limited to picowatts of probe power. Here we demonstrate simultaneous enhancement of precision and sensitivity to beyond the QNL for estimating modulated transmission with a squeezed amplitude probe of $0.2$ mW average ($25$ W peak) power, which is 8 orders of magnitude above the power limitations of previous sub-QNL precision measurements of transmission. Our approach enables measurements that compete with the optical powers of current classical techniques, but have both improved precision and sensitivity beyond the classical limit.

•Dec 1, 2021•38 citations
We use bright squeezed light to demonstrate that direct absorption and gain measurements can be performed with sensitivity beyond the shot-noise limit without requiring homodyne/lock-in, or logic coincidence detection schemes. Previously we reported more than 1 dB quantum advantage [ 3 dB when corrected losses in optical paths] for the measurement sensitivity at faint absorption levels. We present our detailed results on definite quantum advantage of about 3dB in measurements of Brillouin gain.
Absorption measurement is an exceptionally versatile tool for many applications in science and engineering. For absorption measurements using laser beams of light, the sensitivity is theoretically limited by the shot noise due to the fundamental Poisson distribution of the photon number in laser radiation. In practice, the shot-noise limit can only be achieved when all other sources of noise are eliminated. Here, we use seeded squeezed light to demonstrate that direct-absorption measurements can be performed with a sensitivity beyond the shot-noise limit. We present a practically realizable scheme, where intensity-squeezed beams are generated by a seeded four-wave mixing process in an atomic rubidium-vapor cell. More than 1.2 dB quantum advantage for the measurement sensitivity is obtained at faint absorption levels ($\ensuremath{\le}10\mathrm{%}$). We also present a detailed theoretical analysis to show that the observed quantum advantage when corrected for optical loss would be equivalent to 3 dB. Our experiment demonstrates a direct sub-shot-noise measurement of absorption that requires neither homodyne or lock-in nor logic coincidence-detection schemes. It is therefore very applicable in many circumstances where sub-shot-noise-level absorption measurements are highly desirable.
Absorption and gain processes are fundamental to any light-matter interaction and a precise measurement of these parameters is important for various scientific and technological applications. Quantum probes, specifically the squeezed states, have proved very successful, particularly in the applications that deal with phase shift and force measurements. In this paper, we focus on improving the sensitivity of the estimation of the photon-loss coefficient of a weakly absorbing medium as well as the estimation of the gain parameter using a two-mode bright squeezed state. The generation of this state combines the advantage of a coherent beam for its large photon number with the quantum properties of the two-mode squeezing operation in an optical parametric amplifier. We present two measurement schemes: balanced photodetection and time-reversed metrology, both utilizing two-mode bright squeezed light. The maximum quantum advantage we can achieve using two-mode bright squeezed light is 3.7 times for the absorption parameter $\ensuremath{\alpha}=0.05$ and 8.4 times for $\ensuremath{\alpha}=0.01$ as compared to using only the coherent state. Similarly, the maximum quantum advantage for the estimation of optical gain is found around 2.95 times for the gain coefficient G=1.05G=1.05G=1.05 and around 6.35 times for G=1.01G=1.01G=1.01. We discuss the significance of using one measurement scheme over the other under different squeezing conditions. We compare our results with the Cram\'er-Rao bound for a two-mode bright squeezed state to assess the quality of the proposed methodologies.
The use of optical sensing for in vivo applications is compelling, since it offers the advantages of non-invasiveness, non-ionizing radiation, and real-time monitoring. However, the signal-to-noise ratio (SNR) of the optical signal deteriorates dramatically as the biological tissue increases. Although increasing laser power can improve the SNR, intense lasers can severely disturb biological processes and viability. Quantum sensing with bright squeezed light can make the measurement sensitivity break through the quantum noise limit under weak laser conditions. A bright squeezed light source is demonstrated to avoid the deterioration of SNR and biological damage, which integrates an external cavity frequency-doubled laser, a semi-monolithic standing cavity with periodically poled titanyl phosphate (PPKTP), and a balanced homodyne detector (BHD) assembled on a dedicated breadboard. With the rational design of the mechanical elements, the optical layout, and the feedback control equipment, a maximum non-classical noise reduction of −10.7 ± 0.2 dB is observed. The average squeeze of −10 ± 0.2 dB in continuous operation for 60 min is demonstrated. Finally, the intracavity loss of degenerate optical parametric amplifier (DOPA) and the initial bright squeezed light can be calculated to be 0.0021 and −15.5 ± 0.2 dB, respectively. Through the above experimental and theoretical analysis, the direction of improving bright squeeze level is pointed out.
Squeezed states of light enable optical measurements with sensitivity beyond the shot noise limit of detection with classical light. Optical fibers represent a major potential platform for quantum squeezed sensing due to the extremely low loss and perfect single-spatial-mode operation. In this work, we demonstrate two-mode intensity squeezing directly within a commercially available optical fiber, based on a four-wave mixing process. The setup operates in a quasi-continuous-wave mode using 15 ns long pulses and relies on standard laser diode sources, telecommunication electro-optic modulators, and simple photo-detectors. The process is seeded by a coherent signal input, generating bright squeezed output states. Absolute noise reduction by 4 dB below the classical shot-noise limit is detected directly with no post-processing, for output signal and idler pulses of 2.4 × 10 6 photons in average. The results are applicable to quantum interferometry over fiber using simple, readily available components.
Improvements in precision beyond the limit set by the vacuum state or zero-point fluctuations of the field are reported for two optical experiments. Both experiments employ the squeezed light from an optical parametric oscillator to reduce the level of fluctuations in one of two quadrature phase amplitudes below the shot-noise level (SNL). The first experiment follows the work of Caves1 on precision interferometry with squeezed states. An increase in signal-to-noise of 2.5 dB relative to the SNL is demonstrated for the detection of phase modulation in a Mach-Zehnder interferometer. In the second experiment amplitude modulation is encoded on a weak signal beam with an acoustooptic modulator. For the case of a squeezed signal beam compared with a beam in a coherent state, an improvement in sensitivity of 2.5 dB is achieved for the detection of amplitude changes of the field. The observed increases in sensitivity in both experiments are currently limited by simple linear losses in propagation and detection and not by the degree of available squeezing.
Squeezed light enables measurements with sensitivity beyond the quantum noise limit (QNL) for optical techniques such as spectroscopy, gravitational wave detection, magnetometry, and imaging. Precision of a measurement---as quantified by the variance of repeated estimates---has also been enhanced beyond the QNL using squeezed light. However, sub-QNL sensitivity is not sufficient to achieve sub-QNL precision. Furthermore, demonstrations of sub-QNL precision in estimating transmission have been limited to picowatts of probe power. Here we demonstrate simultaneous enhancement of precision and sensitivity to beyond the QNL for estimating modulated transmission with a squeezed amplitude probe of 0.20.20.2 mW average (252525 W peak) power, which is 8 orders of magnitude above the power limitations of previous sub-QNL precision measurements of transmission. Our approach enables measurements that compete with the optical powers of current classical techniques, but have both improved precision and sensitivity beyond the classical limit.