Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optical and Quantum Sensing and Precision Metrology II

Phase locking scheme for squeezed vacuum generated by single-pass optical parametric amplifier

Yoshitaka Taguchi, Yasuyuki Ozeki

Published Mar 3, 2022• 0 citations
Publisher

Abstract

Single-pass optical parametric amplification (OPA) is attractive in the generation of broadband squeezed vacuum. To achieve a higher squeezing level, precise control of the local oscillator (LO) phase is needed. However, the conventional control scheme was designed for squeezing by optical parametric oscillation (OPO). In this study, we propose a new scheme, which is applicable to single-pass OPA. In this scheme, we measure the modulation in the residual pump light after the OPA crystal to realize precise phase-locking of the LO. We anticipate that the proposed scheme will be indispensable for practical applications of squeezing with single-pass OPA.

DOI
10.1117/12.2607559

Related papers

Phase locking of squeezed vacuum generated by a single-pass optical parametric amplifier

Yoshitaka Taguchi, Kenichi Oguchi, Zicong Xu +5 more

In high-precision optical measurements, squeezed vacuum states are a promising resource for reducing the shot noise. To utilize a squeezed vacuum, it is important to lock the phase of the local oscillator (LO) to the squeezed light. The coherent control sideband (CCSB) scheme has been established for the precise phase locking, while the previous CCSB scheme was designed for the squeezed vacuum generated with an optical parametric oscillator (OPO). Thus the previous CCSB scheme is not applicable to squeezing by a single-pass optical parametric amplifier (OPA), which is attractive for generating broadband squeezed vacuum states. In this study, we propose a variant of CCSB scheme, which is applicable to the squeezing by single-pass OPA. In this scheme, we inject pump light and frequency-shifted signal light into an OPA crystal in the same way as the previous CCSB scheme. The parametric process in the OPA crystal generates a squeezed vacuum, amplifies the signal light, generates an idler light, and causes the pump depletion reflecting the interference of the amplified signal light and the idler light. Through the lock-in detection of the pump depletion, we can phase-lock the injected signal light to the pump light. Then, after the heterodyne detection of the signal and the idler light, we get the error signal of LO and realize the precise phase locking of LO to the squeezed quadrature. We show the feasibility of the proposed scheme by deriving the signal-to-noise ratio (SNR) of the modulated pump signal. We experimentally demonstrate the proposed scheme on pulsed squeezing by a single-pass OPA.

Optics Express•Feb 11, 2022•14 citations

Phase Locking of Pulsed Squeezed Light Generated by a Single-Pass Optical Parametric Amplifier

Yoshitaka Taguchi, Kenichi Oguchi, Zicong Xu +5 more

We propose and demonstrate a phase-locking scheme for squeezed vacuum generated by a single-pass optical parametric amplifier. Stable phase locking of picosecond squeezed vacuum with a squeezing level of −1.7 dB was achieved.

Conference on Lasers and Electro-Optics•Jan 1, 2022•0 citations

Generation of 10-dB squeezed light from a broadband waveguide optical parametric amplifier with improved phase locking method

Kazuki Hirota, Takahiro Kashiwazaki, Gyeongmin Ha +10 more

We report generation of 10.1\pm0.2-dB squeezed light from a broadband periodically poled lithium niobate (PPLN) waveguide optical parametric amplifier (OPA). Based on our previous report where a similar PPLN waveguide shows 8.3-dB squeezing [T. Kashiwazaki et al., Appl. Phys. Lett. 122, 234003 (2023)], we reduce phase fluctuations and overall optical losses in the measurement system. In particular, we introduce a novel phase detection technique that does not require tapping a part of the squeezed light to get a phase locking signal. We use a phase-detection OPA seeded by a tapped probe and pump light before a squeezer OPA. This configuration breaks the conventional trade-off between generating a phase-locking signal with high-signal-to-noise ratio and suppressing degradation of squeezing level caused by optical tapping. With all these improvements, the phase fluctuation angle is reduced from 14 mrad to 9 mrad, and the total optical loss from 12\% to 8\%. Achieving more than 10 dB of squeezing by the broadband waveguide OPA is a significant step towards realization of fault-tolerant ultra-fast universal optical quantum computation.

quant-pharXiv:2511.15082•Optics Express•Nov 20, 2025•11 citations

Multimode squeezed light generation and characterization

Alexander Chudakov, Vladislav Severin, Anastasia Poshevkina +5 more

Nowadays, the realization of quantum computations and communications based on continuous variables has attracted a significant attention due to a substantial expansion of the system dimensionality. The main progress in this area is attributed to the implementation of multimode systems based on squeezed states of light. One of the simplest ways to generate such states relies upon their producing in a single-pass optical parametric amplifier (OPA) using ultrafast pumping. However, for homodyne detection of such multimode states, the profile of the local oscillator (LO) must perfectly match the profile of the measured mode. Usually, this is not the case; therefore a proper treatment of multimode squeezing is required. In this work, we study both theoretically and experimentally the multimode squeezed light generated in type-0 and type-II OPA. We characterize such sources and investigate the degree of squeezing in dependence on the LO spectral profile, employing a pulse shaping technique. The theoretical analysis is performed using the Schmidt-mode theory. This work might have a significant impact on the realization of multimode quantum protocols

quant-pharXiv:2609.08591•Sep 9, 2026•1 citation

Generation of Long-Term Stable Squeezed Vacuum States Using Dither-Locking Technique

Daohua Wu, Yashuai Han, Xuehua Zhu +1 more

We report the generation of long-term stable squeezed vacuum states at 1064 nm using a degenerate optical parametric amplifier (DOPA) with a periodically poled KTiOPO4 crystal (PPKTP). The OPA is pumped by a 532 nm light produced by frequency doubling the fundamental light with a bow-tie enhancement second harmonic generator (SHG). When the DOPA and relative phases are locked using a dither-locking method, the squeezed vacuum states are stably measured over 2 h at 11 MHz. The highly compact and simple squeezed light source is suitable for applications in quantum optics experiments.

Photonics•Jul 6, 2022•2 citations

Effect of phase-sensitive manipulations on generation of low-frequency two-mode orthogonal squeezed vacuum states

Wei Wu, Hao Ming Zhao, Jinxia Feng +3 more

Two-mode orthogonal squeezed vacuum states are an important quantum resource for quantum communication, quantum computing, quantum simulation, quantum precision measurement and sensing. It is essential to obtain stable two-mode orthogonal squeezed vacuum states in a low frequency range and compact configurations for practical applications, especially in quantum precision measurement and sensing. Two-mode orthogonal squeezed vacuum states are commonly produced via a subthreshold nondegenerate optical parametric amplifier (NOPA) in a continuous variable system. However, it is a difficult problem that the subthreshold NOPA cavity is phase sensitive manipulated to obtain stable squeezed vacuum states. Previous signal light injecting scheme relies on an injection of a weak light field into the subthreshold NOPA for phase sensitive manipulation. The injected signal light has the same frequency as the generated squeezed vacuum state. Thereby even the weakest injected signal light can introduce large amounts of excessive noise at low frequencies and the squeezing degree of two-mode squeezed vacuum states will be reduced or squeezing cannot be achieved. In this paper, a single sideband frequency shifted light injecting scheme is proposed for phase sensitive manipulation of NOPA. The comparison between the single sideband frequency shifted light injecting scheme and the signal light injecting scheme for realization of phase sensitive manipulation of NOPA is conducted. The effects of the two schemes on the generation of the low-frequency two-mode orthogonal squeezed vacuum state light field are investigated experimentally . The experimental results show that in the signal light injecting scheme for phase sensitive manipulation, the squeezing degree of the two-mode orthogonal squeezed vacuum state continuously decreases until it disappears as the power of injected signal light increases. In the process of phase sensitive manipulation of NOPA by using the single sideband frequency shifted light injecting scheme, the squeezing degree of the two-mode orthogonal squeezed vacuum state does not change with the power of the injected frequency shifted light increasing. Stable phase sensitive manipulation is realized by injecting single sideband frequency shifted light into NOPA. The NOPA is operated in a phase sensitive amplification state for 30 min. Stable low-frequency two-mode orthogonal squeezed vacuum states are obtained. The (4.1 ± 0.1) dB amplitude orthogonal squeezed vacuum states and (4.0 ± 0.2) dB phase orthogonal squeezed vacuum states at a frequency of 200 kHz are generated stably, in a compact NOPA configuration.

Acta Physica Sinica•Dec 12, 2023•0 citations
Single-pass optical parametric amplification (OPA) is attractive in the generation of broadband squeezed vacuum. To achieve a higher squeezing level, precise control of the local oscillator (LO) phase is needed. However, the conventional control scheme was designed for squeezing by optical parametric oscillation (OPO). In this study, we propose a new scheme, which is applicable to single-pass OPA. In this scheme, we measure the modulation in the residual pump light after the OPA crystal to realize precise phase-locking of the LO. We anticipate that the proposed scheme will be indispensable for practical applications of squeezing with single-pass OPA.
In high-precision optical measurements, squeezed vacuum states are a promising resource for reducing the shot noise. To utilize a squeezed vacuum, it is important to lock the phase of the local oscillator (LO) to the squeezed light. The coherent control sideband (CCSB) scheme has been established for the precise phase locking, while the previous CCSB scheme was designed for the squeezed vacuum generated with an optical parametric oscillator (OPO). Thus the previous CCSB scheme is not applicable to squeezing by a single-pass optical parametric amplifier (OPA), which is attractive for generating broadband squeezed vacuum states. In this study, we propose a variant of CCSB scheme, which is applicable to the squeezing by single-pass OPA. In this scheme, we inject pump light and frequency-shifted signal light into an OPA crystal in the same way as the previous CCSB scheme. The parametric process in the OPA crystal generates a squeezed vacuum, amplifies the signal light, generates an idler light, and causes the pump depletion reflecting the interference of the amplified signal light and the idler light. Through the lock-in detection of the pump depletion, we can phase-lock the injected signal light to the pump light. Then, after the heterodyne detection of the signal and the idler light, we get the error signal of LO and realize the precise phase locking of LO to the squeezed quadrature. We show the feasibility of the proposed scheme by deriving the signal-to-noise ratio (SNR) of the modulated pump signal. We experimentally demonstrate the proposed scheme on pulsed squeezing by a single-pass OPA.
We report generation of 10.1\pm0.2-dB squeezed light from a broadband periodically poled lithium niobate (PPLN) waveguide optical parametric amplifier (OPA). Based on our previous report where a similar PPLN waveguide shows 8.3-dB squeezing [T. Kashiwazaki et al., Appl. Phys. Lett. 122, 234003 (2023)], we reduce phase fluctuations and overall optical losses in the measurement system. In particular, we introduce a novel phase detection technique that does not require tapping a part of the squeezed light to get a phase locking signal. We use a phase-detection OPA seeded by a tapped probe and pump light before a squeezer OPA. This configuration breaks the conventional trade-off between generating a phase-locking signal with high-signal-to-noise ratio and suppressing degradation of squeezing level caused by optical tapping. With all these improvements, the phase fluctuation angle is reduced from 14 mrad to 9 mrad, and the total optical loss from 12\% to 8\%. Achieving more than 10 dB of squeezing by the broadband waveguide OPA is a significant step towards realization of fault-tolerant ultra-fast universal optical quantum computation.
Nowadays, the realization of quantum computations and communications based on continuous variables has attracted a significant attention due to a substantial expansion of the system dimensionality. The main progress in this area is attributed to the implementation of multimode systems based on squeezed states of light. One of the simplest ways to generate such states relies upon their producing in a single-pass optical parametric amplifier (OPA) using ultrafast pumping. However, for homodyne detection of such multimode states, the profile of the local oscillator (LO) must perfectly match the profile of the measured mode. Usually, this is not the case; therefore a proper treatment of multimode squeezing is required. In this work, we study both theoretically and experimentally the multimode squeezed light generated in type-0 and type-II OPA. We characterize such sources and investigate the degree of squeezing in dependence on the LO spectral profile, employing a pulse shaping technique. The theoretical analysis is performed using the Schmidt-mode theory. This work might have a significant impact on the realization of multimode quantum protocols
We report the generation of long-term stable squeezed vacuum states at 1064 nm using a degenerate optical parametric amplifier (DOPA) with a periodically poled KTiOPO4 crystal (PPKTP). The OPA is pumped by a 532 nm light produced by frequency doubling the fundamental light with a bow-tie enhancement second harmonic generator (SHG). When the DOPA and relative phases are locked using a dither-locking method, the squeezed vacuum states are stably measured over 2 h at 11 MHz. The highly compact and simple squeezed light source is suitable for applications in quantum optics experiments.
Two-mode orthogonal squeezed vacuum states are an important quantum resource for quantum communication, quantum computing, quantum simulation, quantum precision measurement and sensing. It is essential to obtain stable two-mode orthogonal squeezed vacuum states in a low frequency range and compact configurations for practical applications, especially in quantum precision measurement and sensing. Two-mode orthogonal squeezed vacuum states are commonly produced via a subthreshold nondegenerate optical parametric amplifier (NOPA) in a continuous variable system. However, it is a difficult problem that the subthreshold NOPA cavity is phase sensitive manipulated to obtain stable squeezed vacuum states. Previous signal light injecting scheme relies on an injection of a weak light field into the subthreshold NOPA for phase sensitive manipulation. The injected signal light has the same frequency as the generated squeezed vacuum state. Thereby even the weakest injected signal light can introduce large amounts of excessive noise at low frequencies and the squeezing degree of two-mode squeezed vacuum states will be reduced or squeezing cannot be achieved. In this paper, a single sideband frequency shifted light injecting scheme is proposed for phase sensitive manipulation of NOPA. The comparison between the single sideband frequency shifted light injecting scheme and the signal light injecting scheme for realization of phase sensitive manipulation of NOPA is conducted. The effects of the two schemes on the generation of the low-frequency two-mode orthogonal squeezed vacuum state light field are investigated experimentally . The experimental results show that in the signal light injecting scheme for phase sensitive manipulation, the squeezing degree of the two-mode orthogonal squeezed vacuum state continuously decreases until it disappears as the power of injected signal light increases. In the process of phase sensitive manipulation of NOPA by using the single sideband frequency shifted light injecting scheme, the squeezing degree of the two-mode orthogonal squeezed vacuum state does not change with the power of the injected frequency shifted light increasing. Stable phase sensitive manipulation is realized by injecting single sideband frequency shifted light into NOPA. The NOPA is operated in a phase sensitive amplification state for 30 min. Stable low-frequency two-mode orthogonal squeezed vacuum states are obtained. The (4.1 ± 0.1) dB amplitude orthogonal squeezed vacuum states and (4.0 ± 0.2) dB phase orthogonal squeezed vacuum states at a frequency of 200 kHz are generated stably, in a compact NOPA configuration.