Schrodinger’s cat describes a paradox in which a cat is located in a sealed black box with a poison sealed capsule inside it. Radioactive source decays and emits radiation, which activates a Geiger counter, The Geiger counter generates a signal to release poison from the capsule and kill the cat. Since the decay of a radioactive source is a random sub atomic event, based on quantum mechanics we can only derive a probability-based assumption on the exact time that the decay of the radioactive atom will occur. The Copenhagen interpretation says that until an observer opens the box, the entire system is in superposition and the cat is both dead and alive. In this paper, I will show that we can extrapolate this superposition paradox also to the time domain and the entropy level of the system.
We measure event-by-event discrete changes in the net electric charge of an optically levitated silica microsphere arising from individual radioactive decays within the sphere, in coincidence with energy depositions in a nearby scintillation detector. The net charge of the levitated sphere is continuously monitored by measuring its driven response to an oscillating electric field, allowing individual charge-change events to be resolved on millisecond timescales with precision below an elementary charge. Simultaneously,
α and
β particles emitted during decays of implanted
212Pb and its daughters are detected using a scintillator read out with an array of silicon photomultipliers. By correlating reconstructed charge-change times with the scintillator response, we can directly attribute abrupt changes in the sphere's net charge to individual nuclear decays, and identify differences in the distribution of charges ejected for
α and
β decays. These results establish a new approach for studying low energy charged particles emitted by radioactive decays at the single-decay level, and identify showers of radiogenically produced low-energy electrons emitted by
α-decaying radon daughters implanted near solid surfaces.