Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE

Optimising single electron transistors as electrometers for high-precision electrometry of charge on quantum dots

Vincent I. Conrad, Andrew D. Greentree, David N. Jamieson, Lloyd C. L. Hollenberg

Published Jan 1, 2005• 0 citations
OpenAlex

Related papers

Superconducting single electron transistor for charge sensing in Si/SiGe-based quantum dots

Zhen Yang

•Jan 1, 2015•0 citations

Radio-Frequency Single-Electron Transistor Coupled to an Electrostatically Defined Quantum Dot

Wei Dong Lu, A. J. Rimberg, Daniel C. Driscoll +1 more

APS•Mar 1, 2002•0 citations

Toward a quantum-limited charge detector

Nadia Court, D. J. Reilly, Tilo M. Buehler +2 more

The radio-frequency single-electron-transistor (rf-SET) is an electrometer that can sense a fraction of an electron charge on microsecond timescales. At present this device is prevented from reaching quantum limits by the noise contribution of the post-amplifier, generally a cryogenic high-electron mobility transistor (HEMT). We present results to date in our effort to construct an alternative post-amplifier based on the dc superconducting quantum interference device (SQUID). These SQUID-based amplifiers, which are fabricated in aluminium via electron beam lithography and shadow mask evaporation open the possibility of near-quantum-limited electrometry with the rf-SET.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Feb 28, 2005•1 citation

Fabrication and Characterization of Double Single-Electron Transistors as a Readout for Charge Qubits

Y. Kawata, Manoharan Muruganathan, Yoshishige Tsuchiya +2 more

•Jun 1, 2007•1 citation

rf-electrometer using a carbon nanotube resonant tunneling transistor

Lorenz Lechner, Fan Wu, R. Danneau +2 more

We have studied resonant tunneling transistors (RTT) made of single-walled carbon nanotube quantum dots in the Fabry–Pérot regime. We show sensitivity to input charge as high as 5×10−6 e/Hz1/2 with a carrier frequency of 719 MHz at 4.2 K. This result is comparable to the best values of charge sensitivity so far reported for radio frequency single electron transistors (rf-SET). Unlike SETs, whose operating temperature is limited as Coulomb blockade vanishes as 1/T, a RTT can operate at higher temperatures, since the dephasing length lϕ∝1/T2/3.

Journal of Applied Physics•Apr 15, 2010•3 citations

Coherent Electrometer Using Hybridised Double Quantum Dot - Resonator States

Samuel Andersson, P. Glidic, Andrea Cicovic +4 more

Probing the change in conductance or reactance of a charge sensitive system using an rf cavity is a standard way of doing fast single-charge electrometry. In this article, we present a detector concept which is instead based on coherent interaction. We show that the coherent interaction between a microwave resonator and double quantum dot gives rise to a fast, highly sensitive electrometer. The coherent electrometer achieves a state-of-the-art readout speed, resolving two charge states with SNR of 11.7 in 16 $μ$s, with a readout signal two orders of magnitude lower in power than previously required to reach this speed. In this way, heating of the sample becomes negligible. Thanks to its sensitivity and low dissipation, the coherent electrometer opens up the avenue for quantum limited charge detection with nanosecond speed and minimal back-action.

arXiv:2611.10274•Nov 6, 2026•0 citations
The radio-frequency single-electron-transistor (rf-SET) is an electrometer that can sense a fraction of an electron charge on microsecond timescales. At present this device is prevented from reaching quantum limits by the noise contribution of the post-amplifier, generally a cryogenic high-electron mobility transistor (HEMT). We present results to date in our effort to construct an alternative post-amplifier based on the dc superconducting quantum interference device (SQUID). These SQUID-based amplifiers, which are fabricated in aluminium via electron beam lithography and shadow mask evaporation open the possibility of near-quantum-limited electrometry with the rf-SET.
We have studied resonant tunneling transistors (RTT) made of single-walled carbon nanotube quantum dots in the Fabry–Pérot regime. We show sensitivity to input charge as high as 5×10−6 e/Hz1/2 with a carrier frequency of 719 MHz at 4.2 K. This result is comparable to the best values of charge sensitivity so far reported for radio frequency single electron transistors (rf-SET). Unlike SETs, whose operating temperature is limited as Coulomb blockade vanishes as 1/T, a RTT can operate at higher temperatures, since the dephasing length lϕ∝1/T2/3.
Probing the change in conductance or reactance of a charge sensitive system using an rf cavity is a standard way of doing fast single-charge electrometry. In this article, we present a detector concept which is instead based on coherent interaction. We show that the coherent interaction between a microwave resonator and double quantum dot gives rise to a fast, highly sensitive electrometer. The coherent electrometer achieves a state-of-the-art readout speed, resolving two charge states with SNR of 11.7 in 16 μμμs, with a readout signal two orders of magnitude lower in power than previously required to reach this speed. In this way, heating of the sample becomes negligible. Thanks to its sensitivity and low dissipation, the coherent electrometer opens up the avenue for quantum limited charge detection with nanosecond speed and minimal back-action.