Physical Review A

Sensitive spatially resolved magnetometry using a Bose-condensed gas with a bright probe

Naota Sekiguchi, Kosuke Shibata, Aki Torii, Hiroyuki Toda, Ryohei Kuramoto, Daiki Fukuda, Takuya Hirano

Published Oct 28, 2021• 12 citations
Publisher

Abstract

We demonstrate a sensitive spatially resolved magnetometer using a spinor Bose-Einstein condensate (BEC) of $^{87}\mathrm{Rb}$ atoms with increased probe fluence. By performing a probe parameter search using a two-polarization phase contrast imaging technique, we find that the probe-induced atom loss, a major constraint in optical magnetometry with high-density gas, can be reduced. We attain a sensitivity of 5.4(6) mrad for the phase measurement of Larmor precession using a measurement area of $1.4\ifmmode\times\else\texttimes\fi{}{10}^{2}\phantom{\rule{3.33333pt}{0ex}}\ensuremath{\mu}{\mathrm{m}}^{2}$ with a probe fluence of $4.1\ifmmode\times\else\texttimes\fi{}{10}^{5}\phantom{\rule{3.33333pt}{0ex}}\ensuremath{\mu}{\mathrm{m}}^{\ensuremath{-}2}$. A dc magnetic field sensitivity of $5.0(4)\phantom{\rule{3.33333pt}{0ex}}\mathrm{pT}/\sqrt{\mathrm{Hz}}$ is attained with a probe fluence of $3.9\ifmmode\times\else\texttimes\fi{}{10}^{5}\phantom{\rule{4pt}{0ex}}\ensuremath{\mu}{\mathrm{m}}^{\ensuremath{-}2}$. The results should contribute to further enhancement of the sensitivity of a BEC magnetometer.

DOI
10.1103/physreva.104.l041306

Related papers

Sensitive BEC magnetometry with optimized probing

Naota Sekiguchi, Aki Torii, Hiroyuki Toda +4 more

An improved spatial magnetometer using a spinor Bose-Einstein condensate of $^{87}$Rb atoms is realized utilizing newly developed two-polarization phase contrast imaging. The optical shot noise is suppressed by carefully choosing the probe parameters. We attain a dc-magnetic field sensitivity of 7.7 ${\rm pT/\sqrt{Hz}}$ over a measurement area of 28 ${\rm μm^{2}}$. The attained sensitivity per unit area is superior to that for other modern low-frequency magnetometers with micrometer-order spatial resolution. This result is a promising step for realizing quantum-enhanced magnetometry surpassing classical methods.

arXiv:2009.07569•Sep 16, 2020•2 citations

High-Resolution Magnetometry with a Spinor Bose-Einstein Condensate

Mukund Vengalattore, James Higbie, Sabrina R. Leslie +3 more

We demonstrate a precise magnetic microscope based on direct imaging of the Larmor precession of a $^{87}\mathrm{Rb}$ spinor Bose-Einstein condensate. This magnetometer attains a field sensitivity of $8.3\text{ }\text{ }\mathrm{pT}/{\mathrm{Hz}}^{1/2}$ over a measurement area of $120\text{ }\text{ }\ensuremath{\mu}{\mathrm{m}}^{2}$, an improvement over the low-frequency field sensitivity of modern SQUID magnetometers. The achieved phase sensitivity is close to the atom shot-noise limit, estimated as $0.15\text{ }\text{ }\mathrm{pT}/{\mathrm{Hz}}^{1/2}$ for a unity duty cycle measurement, suggesting the possibilities of spatially resolved spin-squeezed magnetometry. This magnetometer marks a significant application of degenerate atomic gases to metrology.

arXiv:cond-mat/0612685•Physical Review Letters•May 17, 2007•246 citations

Direct Nondestructive Imaging of Magnetization in a Spin-1 Bose-Einstein Gas

James Higbie, Lorraine E. Sadler, S. Inouye +5 more

Polarization-dependent phase-contrast imaging is used to resolve the spatial magnetization profile of an optically trapped ultracold gas. This probe is applied to Larmor precession of degenerate and nondegenerate spin-1 87Rb gases. Transverse magnetization of the Bose-Einstein condensate persists for the condensate lifetime, with a spatial response to magnetic field inhomogeneities consistent with a mean-field model of interactions. In comparison, the magnetization of the non-condensed gas decoheres rapidly. Rotational symmetry implies that the Larmor frequency of a spinor condensate be density independent, and thus suitable for precise magnetometry with high spatial resolution.

arXiv:cond-mat/0502517•Physical Review Letters•Jul 26, 2005•232 citations

Ultra-cold atomic magnetometry: realisation and test of a ⁸⁷Rb BEC for high-sensitivity magnetic field measurements

Michela Venturelli

The development of an experimental apparatus to produce Bose-Einstein condensates (BECs) of ⁸⁷Rb atoms and their application to magnetometry are discussed. Optical detection of atomic Larmor precession is a widely explored method for high-sensitivity measurements of magnetic fields. In this context, short laser/atom interaction time, atomic thermal diffusion and decoherence effects are among the main limitations. In this thesis, we overcome such problems by using spin-polarised ⁸⁷Rb ultra-cold atoms as the sensing element. After the atoms are polarised, a resonant pulse of radio-frequency excites Larmor precession, which is sensitive to external magnetic fields. By measuring the perturbations of the radio-frequency induced spin precession, information on the magnetic fields of interest. This is achieved by monitoring the polarisation plane’s rotation of a linearly polarised resonant laser probe. In the first part of this thesis, the building and optimisation of a laser-cooling set up to obtain a BEC in a hybrid trap is reported. In order to achieve the Phase Space Density (PSD) required for BEC, several different stages of trapping and cooling are necessary. Each phase has been implemented and optimised. The first step consists in the magneto-optical trap (MOT). Here a velocity dependent damping force and a spatially dependent confining force give the largest changes in PSD. Then atoms are loaded into a hybrid trap obtained by overlapping a quadrupole magnetic potential and a far detuned optical crossed dipole trap. The final stage for the condensation consists of forced evaporative cooling, both via magnetic and optical evaporation. In the second part of the thesis, a general overview of the principles of optical atomic magnetometry is provided and the advantages of using ultra-cold atoms with respect to conventional thermal vapours are discussed. The implementation, operation and a preliminary characterisation of the ultra-cold atom magnetometer are described along with the preliminary results collected. Finally, a plan for future improvements of its sensitivity is presented.

•Sep 28, 2018•0 citations

Continuous Faraday measurement of spin precession without light shifts

M. Jasperse, Michael J. Kewming, S. N. Fischer +3 more

We describe a dispersive Faraday optical probe of atomic spin which performs a weak measurement of spin projection of a quantum gas continuously for more than one second. To date, focusing bright far-off-resonance probes onto quantum gases has proved invasive due to strong scalar and vector light shifts exerting dipole and Stern-Gerlach forces. We show that tuning the probe near the magic-zero wavelength at 790 nm between the fine-structure doublet of $^{87}\mathrm{Rb}$ cancels the scalar light shift, and careful control of polarization eliminates the vector light shift. Faraday rotations due to each fine-structure line reinforce at this wavelength, enhancing the signal-to-noise ratio for a fixed rate of probe-induced decoherence. Using this minimally invasive spin probe, we perform microscale atomic magnetometry at high temporal resolution. Spectrogram analysis of the Larmor precession signal of a single spinor Bose-Einstein condensate measures a time-varying magnetic field strength with 1 $\ensuremath{\mu}\mathrm{G}$ accuracy every 5 ms; or, equivalently, makes more than 200 successive measurements each at $10\phantom{\rule{0.16em}{0ex}}\mathrm{pT}/\sqrt{\mathrm{Hz}}$ sensitivity.

arXiv:1705.10965•Physical Review A•Dec 1, 2017•22 citations

Quantum gas microscopy for magnetic field imaging and current density mapping of nanostructures

Poppy Joshi (11375517)

People have been measuring magnetic fields since 200 BC, giving rise to the field of magnetometry. Recently there has been a drive to measure smaller fields with better resolution, resulting in the production of many different types of magnetometers, each with their own unique features. These magnetometers can have a diverse range of applications such as, GNSS free navigation, biomedical sensing, space and weather measurements, and material physics. When designing a magnetomoter there is a trade off between high sensitivity to magnetic fields and high spatial resolution. Currently, there is a unoccupied niche in direct current (DC) magnetometry, that requires a magnetic field sensitivity in the picotesla range and micron scale spatial resolution. Here, I introduce the Bose-Einstein condensate (BEC), which is a macroscopic quantum object, ideal for probing magnetic fields on the nanotesla to picotesla range, with micron scale resolution. This thesis discusses the use of a BEC microscope (BEC-M) to characterise mate- rials with novel applications in nanotechnology by producing 2D current density maps. To produce the atomic probe for microscopy, a BEC in the quasi-1D regime is carefully prepared, requiring an ultra high vacuum (UHV) environment along with custom designed trapping structures, to optically and magnetically confine the atoms. The sensitivity and resolution of the BEC-M makes it an ideal tool for characterising electrical properties of structures on the micron scale such as carbon nanotube (CNT) bundles and biological samples. Current network configuration in samples such as these, can be mapped via a raster scanning procedure. A measurement was made to identify current pathways in CNTs by measuring the atomic distribution of the ultra cold cloud and converting these images to magnetic field and current density maps.

•Jun 6, 2025•0 citations
We demonstrate a sensitive spatially resolved magnetometer using a spinor Bose-Einstein condensate (BEC) of 87Rb^{87}\mathrm{Rb}87Rb atoms with increased probe fluence. By performing a probe parameter search using a two-polarization phase contrast imaging technique, we find that the probe-induced atom loss, a major constraint in optical magnetometry with high-density gas, can be reduced. We attain a sensitivity of 5.4(6) mrad for the phase measurement of Larmor precession using a measurement area of 1.4\ifmmode×\else\texttimes\fi102\ensuremathμm21.4\ifmmode\times\else\texttimes\fi{}{10}^{2}\phantom{\rule{3.33333pt}{0ex}}\ensuremath{\mu}{\mathrm{m}}^{2}1.4\ifmmode×\else\texttimes\fi102\ensuremathμm2 with a probe fluence of 4.1\ifmmode×\else\texttimes\fi105\ensuremathμm\ensuremath−24.1\ifmmode\times\else\texttimes\fi{}{10}^{5}\phantom{\rule{3.33333pt}{0ex}}\ensuremath{\mu}{\mathrm{m}}^{\ensuremath{-}2}4.1\ifmmode×\else\texttimes\fi105\ensuremathμm\ensuremath−2. A dc magnetic field sensitivity of 5.0(4)pT/Hz5.0(4)\phantom{\rule{3.33333pt}{0ex}}\mathrm{pT}/\sqrt{\mathrm{Hz}}5.0(4)pT/Hz​ is attained with a probe fluence of 3.9\ifmmode×\else\texttimes\fi105\ensuremathμm\ensuremath−23.9\ifmmode\times\else\texttimes\fi{}{10}^{5}\phantom{\rule{4pt}{0ex}}\ensuremath{\mu}{\mathrm{m}}^{\ensuremath{-}2}3.9\ifmmode×\else\texttimes\fi105\ensuremathμm\ensuremath−2. The results should contribute to further enhancement of the sensitivity of a BEC magnetometer.
An improved spatial magnetometer using a spinor Bose-Einstein condensate of 87^{87}87Rb atoms is realized utilizing newly developed two-polarization phase contrast imaging. The optical shot noise is suppressed by carefully choosing the probe parameters. We attain a dc-magnetic field sensitivity of 7.7 pT/Hz{\rm pT/\sqrt{Hz}}pT/Hz​ over a measurement area of 28 μm2{\rm μm^{2}}μm2. The attained sensitivity per unit area is superior to that for other modern low-frequency magnetometers with micrometer-order spatial resolution. This result is a promising step for realizing quantum-enhanced magnetometry surpassing classical methods.
We demonstrate a precise magnetic microscope based on direct imaging of the Larmor precession of a 87Rb^{87}\mathrm{Rb}87Rb spinor Bose-Einstein condensate. This magnetometer attains a field sensitivity of 8.3  pT/Hz1/28.3\text{ }\text{ }\mathrm{pT}/{\mathrm{Hz}}^{1/2}8.3  pT/Hz1/2 over a measurement area of $120\text{ }\text{ }\ensuremath{\mu}{\mathrm{m}}^{2}$, an improvement over the low-frequency field sensitivity of modern SQUID magnetometers. The achieved phase sensitivity is close to the atom shot-noise limit, estimated as 0.15  pT/Hz1/20.15\text{ }\text{ }\mathrm{pT}/{\mathrm{Hz}}^{1/2}0.15  pT/Hz1/2 for a unity duty cycle measurement, suggesting the possibilities of spatially resolved spin-squeezed magnetometry. This magnetometer marks a significant application of degenerate atomic gases to metrology.
Polarization-dependent phase-contrast imaging is used to resolve the spatial magnetization profile of an optically trapped ultracold gas. This probe is applied to Larmor precession of degenerate and nondegenerate spin-1 87Rb gases. Transverse magnetization of the Bose-Einstein condensate persists for the condensate lifetime, with a spatial response to magnetic field inhomogeneities consistent with a mean-field model of interactions. In comparison, the magnetization of the non-condensed gas decoheres rapidly. Rotational symmetry implies that the Larmor frequency of a spinor condensate be density independent, and thus suitable for precise magnetometry with high spatial resolution.
The development of an experimental apparatus to produce Bose-Einstein condensates (BECs) of ⁸⁷Rb atoms and their application to magnetometry are discussed. Optical detection of atomic Larmor precession is a widely explored method for high-sensitivity measurements of magnetic fields. In this context, short laser/atom interaction time, atomic thermal diffusion and decoherence effects are among the main limitations. In this thesis, we overcome such problems by using spin-polarised ⁸⁷Rb ultra-cold atoms as the sensing element. After the atoms are polarised, a resonant pulse of radio-frequency excites Larmor precession, which is sensitive to external magnetic fields. By measuring the perturbations of the radio-frequency induced spin precession, information on the magnetic fields of interest. This is achieved by monitoring the polarisation plane’s rotation of a linearly polarised resonant laser probe. In the first part of this thesis, the building and optimisation of a laser-cooling set up to obtain a BEC in a hybrid trap is reported. In order to achieve the Phase Space Density (PSD) required for BEC, several different stages of trapping and cooling are necessary. Each phase has been implemented and optimised. The first step consists in the magneto-optical trap (MOT). Here a velocity dependent damping force and a spatially dependent confining force give the largest changes in PSD. Then atoms are loaded into a hybrid trap obtained by overlapping a quadrupole magnetic potential and a far detuned optical crossed dipole trap. The final stage for the condensation consists of forced evaporative cooling, both via magnetic and optical evaporation. In the second part of the thesis, a general overview of the principles of optical atomic magnetometry is provided and the advantages of using ultra-cold atoms with respect to conventional thermal vapours are discussed. The implementation, operation and a preliminary characterisation of the ultra-cold atom magnetometer are described along with the preliminary results collected. Finally, a plan for future improvements of its sensitivity is presented.
We describe a dispersive Faraday optical probe of atomic spin which performs a weak measurement of spin projection of a quantum gas continuously for more than one second. To date, focusing bright far-off-resonance probes onto quantum gases has proved invasive due to strong scalar and vector light shifts exerting dipole and Stern-Gerlach forces. We show that tuning the probe near the magic-zero wavelength at 790 nm between the fine-structure doublet of 87Rb^{87}\mathrm{Rb}87Rb cancels the scalar light shift, and careful control of polarization eliminates the vector light shift. Faraday rotations due to each fine-structure line reinforce at this wavelength, enhancing the signal-to-noise ratio for a fixed rate of probe-induced decoherence. Using this minimally invasive spin probe, we perform microscale atomic magnetometry at high temporal resolution. Spectrogram analysis of the Larmor precession signal of a single spinor Bose-Einstein condensate measures a time-varying magnetic field strength with 1 $\ensuremath{\mu}\mathrm{G}$ accuracy every 5 ms; or, equivalently, makes more than 200 successive measurements each at 10pT/Hz10\phantom{\rule{0.16em}{0ex}}\mathrm{pT}/\sqrt{\mathrm{Hz}}10pT/Hz​ sensitivity.
People have been measuring magnetic fields since 200 BC, giving rise to the field of magnetometry. Recently there has been a drive to measure smaller fields with better resolution, resulting in the production of many different types of magnetometers, each with their own unique features. These magnetometers can have a diverse range of applications such as, GNSS free navigation, biomedical sensing, space and weather measurements, and material physics. When designing a magnetomoter there is a trade off between high sensitivity to magnetic fields and high spatial resolution. Currently, there is a unoccupied niche in direct current (DC) magnetometry, that requires a magnetic field sensitivity in the picotesla range and micron scale spatial resolution. Here, I introduce the Bose-Einstein condensate (BEC), which is a macroscopic quantum object, ideal for probing magnetic fields on the nanotesla to picotesla range, with micron scale resolution. This thesis discusses the use of a BEC microscope (BEC-M) to characterise mate- rials with novel applications in nanotechnology by producing 2D current density maps. To produce the atomic probe for microscopy, a BEC in the quasi-1D regime is carefully prepared, requiring an ultra high vacuum (UHV) environment along with custom designed trapping structures, to optically and magnetically confine the atoms. The sensitivity and resolution of the BEC-M makes it an ideal tool for characterising electrical properties of structures on the micron scale such as carbon nanotube (CNT) bundles and biological samples. Current network configuration in samples such as these, can be mapped via a raster scanning procedure. A measurement was made to identify current pathways in CNTs by measuring the atomic distribution of the ultra cold cloud and converting these images to magnetic field and current density maps.