Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Detection of nuclear magnetic resonance using a super conducting quantum magnetometer

J. Bürget, Milan Odehnal

Published Jan 1, 1973• 0 citations
OpenAlex

Related papers

Raman heterodyne detection of nuclear magnetic resonance (A)

Masaharu Mitsunaga, Emily S. Kintzer, J. Mlynek +3 more

Journal of the Optical Society of America B•Jan 1, 1984•0 citations

Possible detection of macroscopic quantum spectra using a magnetic resonance technique

N. Q. Fan, John H. Miller

Physica C Superconductivity•May 1, 1996•0 citations

Spin-Damping in an Ultra-Sensitive Tunable RF Atomic Magnetometer

Orang Alem

Optically pumped radio frequency (RF) atomic magnetometers have been shown to have an improved sensitivity over standard tuned coils for frequencies less than 50 MHz, making these RF magnetometers attractive for the detection of nuclear quadrupole resonance (NQR) and low-field nuclear magnetic resonance (NMR) signals. In an atomic magnetometer a linearly polarized probe beam measures, through Faraday rotation, the transverse atomic magnetization induced by the resonant RF signal. The resonance, or Larmor, frequency of the magnetometer is easily tuned with a small magnetic field. We construct an atomic magnetometer based on a potassium vapor cell with a measured sensitivity of 0.22 ± 0.02 fT/ √ Hz and a detection bandwidth of 334 ± 11 Hz when tuned to 423 kHz, giving a Q of over 1200. While high Q magnetometers are sensitive to weak magnetic fields, they are also sensitive to magnetic transients, such as those associated with the excitation pulses needed for magnetic resonance. The ringing created by such transients can obscure the signal of interest. This is particularly detrimental for magnetic resonance signals that decay faster than the transverse relaxation rate. We demonstrate that by feeding back part of the optical signal to orthogonal electromagnetic coils, this unwanted ringing can be quickly damped out leaving the magnetometer ready for the detection of the signal. This negative feedback as applied to the K spins is called spin-damping and can be used to relax the K atoms faster by more than two orders of magnitude. Using spin-damping we reduce the dead-time before data acquisition from 0.8 to 0.2 ms in the detection of NQR signals from ammonium nitrate, one of the so-called fertilizer bomb explosives with an NQR frequency of 423 kHz. Furthermore, we discover that spin-damping can not only be used to suppress signals, it can also be used to suppress noise. We show that it can be used to suppress both environmental noise and more fundamental quantum noise, such as photon shot and spin projection noise. The latter suppression opens the door for its use in quantum control to initialize spin systems before measurements. For phase-sensitive detection, as is often used in magnetic resonance, spin-damping suppresses signal and noise in such a way as to increase the sensitivity bandwidth of the magnetometer. We prove, both theoretically and experimentally, that it is possible to increase the magnetometer detection bandwidth by a factor of 3 or more without significant loss in sensitivity. Such gains in bandwidth for a high Q magnetometer translate into savings in detection time, particularly for substance detection where the frequency of the signal of interest may not be completely known.

•Aug 18, 2011•1 citation

Broadband Ultra-Sensitive Adiabatic Magnetometer

Igor Savukov, Young Jin Kim

We introduce a new ultra-sensitive adiabatic magnetometer that has a broad bandwidth and can operate in the presence of magnetic fields and gradients. It follows conceptually typical implementations of atomic magnetometers based on alkali-metal vapor cells and lasers for optical pumping and optical Faraday effect detection, while its unique feature is a measurement of an oscillating magnetic field along the probe beam direction at frequencies lower than the resonant frequency, proportional to a static magnetic field along the pump beam direction. The bandwidth of the adiabatic magnetometer scales as the strength of the field along the pump beam. From our theoretical studies it is expected that the adiabatic magnetometer can reach 1 fT sensitivity with a bandwidth of 10 kHz, which any type of atomic magnetometers cannot achieve. Among anticipated various applications of this adiabatic magnetometer are biomagnetic sensing, nuclear magnetic resonance detection, and alkali-metal density measurements. We experimentally conducted alkali-metal density measurements, as an example of applications.

IEEE Sensors Applications Symposium (SAS)•Aug 23, 2021•1 citation

Detection of low magnetic field by means of nuclear resonance of beats

Ion I. Geru

Sensors and Actuators A Physical•Apr 1, 1997•0 citations

Quadrature-detected zero-to-ultralow-field nuclear magnetic resonance

Anne M. Fabricant, Florin Teleanu, Adam Ortmeier +6 more

We present the concept of quadrature-detected zero-to-ultralow-field nuclear magnetic resonance (QD ZULF NMR). Two orthogonal sensors, atomic optically pumped magnetometers, are used to separately detect components of oscillating sample magnetization, which are then combined into a quadrature signal. This approach enables the distinction of positive and negative resonance frequencies with respect to the laboratory frame---such that absolute signs of gyromagnetic ratios can be determined. In addition, QD ZULF NMR reduces peak density and overlap compared to ZULF NMR with single-axis detection, while providing richer information about nuclear-spin dynamics. As an illustration, we present experimental $J$-spectra for thermally polarized [$^{13}$C]-formic acid and [$^{13}$C]-methanol, compounds commonly used in ZULF NMR which represent XA and XA$_3$ spin systems, respectively. A theoretical framework describing QD ZULF NMR signals is provided.

quant-pharXiv:2610.14451•Oct 13, 2026
Optically pumped radio frequency (RF) atomic magnetometers have been shown to have an improved sensitivity over standard tuned coils for frequencies less than 50 MHz, making these RF magnetometers attractive for the detection of nuclear quadrupole resonance (NQR) and low-field nuclear magnetic resonance (NMR) signals. In an atomic magnetometer a linearly polarized probe beam measures, through Faraday rotation, the transverse atomic magnetization induced by the resonant RF signal. The resonance, or Larmor, frequency of the magnetometer is easily tuned with a small magnetic field. We construct an atomic magnetometer based on a potassium vapor cell with a measured sensitivity of 0.22 ± 0.02 fT/ √ Hz and a detection bandwidth of 334 ± 11 Hz when tuned to 423 kHz, giving a Q of over 1200. While high Q magnetometers are sensitive to weak magnetic fields, they are also sensitive to magnetic transients, such as those associated with the excitation pulses needed for magnetic resonance. The ringing created by such transients can obscure the signal of interest. This is particularly detrimental for magnetic resonance signals that decay faster than the transverse relaxation rate. We demonstrate that by feeding back part of the optical signal to orthogonal electromagnetic coils, this unwanted ringing can be quickly damped out leaving the magnetometer ready for the detection of the signal. This negative feedback as applied to the K spins is called spin-damping and can be used to relax the K atoms faster by more than two orders of magnitude. Using spin-damping we reduce the dead-time before data acquisition from 0.8 to 0.2 ms in the detection of NQR signals from ammonium nitrate, one of the so-called fertilizer bomb explosives with an NQR frequency of 423 kHz. Furthermore, we discover that spin-damping can not only be used to suppress signals, it can also be used to suppress noise. We show that it can be used to suppress both environmental noise and more fundamental quantum noise, such as photon shot and spin projection noise. The latter suppression opens the door for its use in quantum control to initialize spin systems before measurements. For phase-sensitive detection, as is often used in magnetic resonance, spin-damping suppresses signal and noise in such a way as to increase the sensitivity bandwidth of the magnetometer. We prove, both theoretically and experimentally, that it is possible to increase the magnetometer detection bandwidth by a factor of 3 or more without significant loss in sensitivity. Such gains in bandwidth for a high Q magnetometer translate into savings in detection time, particularly for substance detection where the frequency of the signal of interest may not be completely known.
We introduce a new ultra-sensitive adiabatic magnetometer that has a broad bandwidth and can operate in the presence of magnetic fields and gradients. It follows conceptually typical implementations of atomic magnetometers based on alkali-metal vapor cells and lasers for optical pumping and optical Faraday effect detection, while its unique feature is a measurement of an oscillating magnetic field along the probe beam direction at frequencies lower than the resonant frequency, proportional to a static magnetic field along the pump beam direction. The bandwidth of the adiabatic magnetometer scales as the strength of the field along the pump beam. From our theoretical studies it is expected that the adiabatic magnetometer can reach 1 fT sensitivity with a bandwidth of 10 kHz, which any type of atomic magnetometers cannot achieve. Among anticipated various applications of this adiabatic magnetometer are biomagnetic sensing, nuclear magnetic resonance detection, and alkali-metal density measurements. We experimentally conducted alkali-metal density measurements, as an example of applications.
We present the concept of quadrature-detected zero-to-ultralow-field nuclear magnetic resonance (QD ZULF NMR). Two orthogonal sensors, atomic optically pumped magnetometers, are used to separately detect components of oscillating sample magnetization, which are then combined into a quadrature signal. This approach enables the distinction of positive and negative resonance frequencies with respect to the laboratory frame---such that absolute signs of gyromagnetic ratios can be determined. In addition, QD ZULF NMR reduces peak density and overlap compared to ZULF NMR with single-axis detection, while providing richer information about nuclear-spin dynamics. As an illustration, we present experimental JJJ-spectra for thermally polarized [13^{13}13C]-formic acid and [13^{13}13C]-methanol, compounds commonly used in ZULF NMR which represent XA and XA3_33​ spin systems, respectively. A theoretical framework describing QD ZULF NMR signals is provided.