Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

(Ultra)cold ion-neutral collisions for new (astro)chemistry

Michal Hejduk, Neville J. A. Coughlan, Jutta Toscano, Lorenzo Salvatore Petralia, Andriana Tsikritea, J. Elworthy, Henry G. McGhee, T. P. Softley, Brianna R. Heazlewood

Published Jan 1, 2018• 1 citation
Publisher

Abstract

We study interactions between a strongly-coupled non-neutral crystallised plasma and slow neutral atoms or molecules in order to understand quantum mechanical effects governing ion-neutral reactions.We employ laser cooling to obtain ion ensembles with sub-Kelvin temperatures in a linear Paul trap. Neutral molecules are manipulated by decelerators operating on the principles of Zeeman, Stark, or collisional cooling effects. In this manner, we reduce the number of quantum states taking part in the scattering event to only a few. In order to reduce this number further, we are constructing a Paul trap with a cryogenicallycooled thermal radiation shield.

DOI
10.13140/rg.2.2.14795.49449

Related papers

Stark deceleration and reactivity of polyatomic molecules and ions at low temperatures

Lee D. Harper

This thesis describes the development of a new experimental technique for studying tunable-collision-energy, quantum state-selected, low-temperature ion-molecule reactions. This has been achieved through the combination of a Stark decelerator for neutral dipolar molecules, and a linear Paul ion trap. The Stark deceleration process for ND3 was examined in detail, through the analysis of experimental data in combination with newly written molecular dynamics simulation programs. In order to prepare a sample of molecules appropriate for collision studies, additional beamline components were introduced after the decelerator. These components were: two hexapoles, to provide transverse focussing, maximising the molecular density; a molecular buncher, providing increased longitudinal velocity resolution; and a fast-opening shutter, to separate decelerated molecules from undecelerated molecules. The sympathetic-cooling of Xe+ ions and ND+3 ions by laser-cooled, Coulomb crystallised 40Ca+ ions with the ion trap was also studied. In particular, the stable trapping of Xe+ was demonstrated for the first time, and the experimental developments that led to this are discussed. The work in this thesis represents significant progress towards studying the reaction of tunable-energy ND3 in the |j,mk> = |1,−1> quantum state with cold Xe+ ions. Ion-molecule reactions utilising ND3 molecules electrostatically guided through the Stark decelerator were performed. It was observed that the main source of error in these experiments was in the calculation of the initial number of Xe+ ions that had been sympathetically cooled into the Coulomb crystal. The sensitivity of the crystal morphology to the number of Xe+ ions was evaluated using molecular dynamics simulations. Strategies have been developed to reduce this uncertainty in future studies. In addition to experimental work, the theory of low temperature ion-molecule reactions has been developed further. The temperature at which classical and quantum mechanical calculations diverge due to purely statistical effects has been investigated using different model intermolecular potentials, for closed-shell and open-shell species, and in the ground and rotationally excited states. From the results of these calculations, several promising candidate reactions have been suggested that might exhibit statistical quantum behaviour at experimentally achievable temperatures.

•Jan 1, 2013•0 citations

Ion-molecule chemistry at very low temperatures: cold chemical reactions between Coulomb-crystallized ions and velocity-selected neutral molecules

Martin T. Bell, Alexander D. Gingell, James M. Oldham +2 more

The recent development of a range of techniques for producing cold atoms and molecules at very low translational temperatures T < or = 1 K has provided the opportunity to investigate collisional processes in a new physical regime. We have recently presented a new experimental method to study low-temperature reactive collisions between translationally cold ions and neutral molecules (S. Willitsch et al., Phys. Rev. Lett. 2008, 100, 043203). Our technique relies on the combination of a quadrupole-guide velocity selector for the generation of translationally cold neutral molecules with a facility to produce ordered structures of cold ions (Coulomb crystals) by laser cooling in a linear quadrupole ion trap. The strong localisation of the ions in the trap in combination with the high sensitivity of laser-induced-fluorescence detection enabled us to study chemical reactions on the single-particle level, down to temperatures of T approximately 1 K. In the current paper, we present a detailed characterisation of the scope and limitations of this method based on our study of the reaction between laser-cooled Ca+ ions and velocity-selected CH3F molecules. The properties of our cold-neutrals source and the dependence of the measured rate constant on the shape of the Coulomb crystals, trapping and laser-cooling parameters are discussed. An extension of our technique for the study of low-temperature reactions with sympathetically cooled molecular ions (translational temperature T > 10 mK) is presented and first results on the charge-transfer reaction between OCS+ and ND3 are discussed. Finally, perspectives for further developments of our method are explored.

Faraday Discussions•Jan 1, 2009•74 citations

Cold reactive collisions between neutral molecules and trapped ions

Lorenzo Salvatore Petralia

This thesis describes the development and demonstration of techniques for the study of ion-neutral reactive collisions at low temperatures conducted using two unique experimental apparatuses comprising radio-frequency Paul traps. One apparatus combines a Stark decelerator with a Paul trap; the other apparatus features a buffer gas cell interfaced with a Paul trap through an electrostatic quadrupole guide. A novel ion trap time-of-flight mass spectrometer has been introduced and characterised. This apparatus is designed to detect the ion products of reactive collisions at low temperatures (< 10 K). This detection approach affords excellent detection efficiency and is broadly applicable to all ion-molecule reactions that one could study within a linear Paul ion trap. A proof-of-principle reaction between xenon ions and neutral ammonia isotopologues is examined to test the performance of the new detection set-up. With the goal of achieving full control over the reaction parameters, the amount of alignment retained by rotationally and translationally cold ammonia molecules exiting the electrostatic guide has been examined using (2 + 1) REMPI detection of the molecules with varying linear polarisation. Simulations suggests how modifications to the current setup will enable full orientation of the cooled molecules reaching the detection region to be achieved. Experiments on cold charge exchange reactions between sympathetically-cooled Xe+ and room temperature ammonia (NH3 and ND3) have been conducted within lasercooled Ca+ Coulomb crystals in a linear Paul ion trap. There is ongoing work to ascertain any difference in reactivity between NH3 and ND3 as the neutral reactant species. Preliminary data are discussed at a qualitative level, with the prospect of observing any isotope effect in this charge transfer process. Charge exchange reaction experiments using cold state-selected ammonia are discussed with the goal of establishing reaction rate constants at different collision energies.

•Jan 1, 2018•0 citations

Investigation of Ultracold Chemical Reactions in a Hybrid System of Laser-Cooled Atoms and Ions

Takashi Mukaiyama, 了一 齋藤

The atom-ion hybrid system provides a new platform to study ultracold collisions and chemical reactions. To investigate chemical reactions in ultracold regimes, we combine neutral atoms in an optical trap and ions in a Paul trap to construct an atom-ion hybrid system. Here we introduce our recent work on ultracold elastic/inelastic collisions at a single atom level with a state-by-state manner. From quantitative discussions on the collision’s cross-sections, we clarified the microscopic collisional mechanisms.

The Review of Laser Engineering•Jan 1, 2021•0 citations

A Cryogenic Molecular Ion-Neutral Hybrid Trap

Claudio von Planta

A hybrid trap was developed to confine neutral molecules and molecular ions. We demonstrated the long-term trapping of Stark-decelerated OH radicals in the X 2Pi3/2 (v = 0, J = 3/2, MJ = 3/2, f) state in a permanent magnetic trap. The trap environment was cryogenically cooled to a temperature of 17 K in order to efficiently suppress black-body-radiation-induced pumping of the molecules out of trappable quantum states and collisions with residual background gas molecules which usually limit the trap lifetimes. The cold molecules were kept confined on timescales approaching minutes, an improvement of up to two orders of magnitude compared to room-temperature experiments, at translational temperatures on the order of 25 mK. A cryogenic ion trap was built and laser cooled Ca+ ions were confined. This ion trap can be used to confine sympathetically cooled molecular ions such as N+2or H2O+. Furthermore, a mechanism to superimpose both trap centers by moving the permanent magnets from the magnetic trap over the ion trap was developed. Both traps were characterized and their functionality was proven. The challenges of lasercooling in the strong magnetic field gradients were discussed. The present results pave the way for investigations of cold collisions and reactions with very small reaction rates between molecular ions and neutral molecules, for new avenues for the production of ultracold molecules via sympathetic cooling and for the realization of new forms of hybrid matter with co-trapped atoms or ions.

•Jan 1, 2020•0 citations

Ultracold Chemical Reaction in a Laser-cooled Atom-ion Mixture

Ryoichi Saito, Shinsuke Haze, Takashi Mukaiyama

The atom-ion hybrid system provides us with new platform to study ultracold collisions and chemical reactions, which play important role in quantum simulations, quantum information processing utilizing atom-ion interactions. To investigate chemical reactions in an ultracold regime, we start with neutral atoms trapped in an optical dipole trap and ions in a linear Paul trap, and combine them together to construct a hybrid system. Here we introduce our recent work on ultracold elastic/inelastic collisions at a single atom level with a state-by-state manner in our atom-ion hybrid system. From the quantitative discussion on the collision cross sections, the microscopic collisional mechanisms have been clarified.

Vacuum and Surface Science•Oct 9, 2020•0 citations
We study interactions between a strongly-coupled non-neutral crystallised plasma and slow neutral atoms or molecules in order to understand quantum mechanical effects governing ion-neutral reactions.We employ laser cooling to obtain ion ensembles with sub-Kelvin temperatures in a linear Paul trap. Neutral molecules are manipulated by decelerators operating on the principles of Zeeman, Stark, or collisional cooling effects. In this manner, we reduce the number of quantum states taking part in the scattering event to only a few. In order to reduce this number further, we are constructing a Paul trap with a cryogenicallycooled thermal radiation shield.
This thesis describes the development of a new experimental technique for studying tunable-collision-energy, quantum state-selected, low-temperature ion-molecule reactions. This has been achieved through the combination of a Stark decelerator for neutral dipolar molecules, and a linear Paul ion trap. The Stark deceleration process for ND3 was examined in detail, through the analysis of experimental data in combination with newly written molecular dynamics simulation programs. In order to prepare a sample of molecules appropriate for collision studies, additional beamline components were introduced after the decelerator. These components were: two hexapoles, to provide transverse focussing, maximising the molecular density; a molecular buncher, providing increased longitudinal velocity resolution; and a fast-opening shutter, to separate decelerated molecules from undecelerated molecules. The sympathetic-cooling of Xe+ ions and ND+3 ions by laser-cooled, Coulomb crystallised 40Ca+ ions with the ion trap was also studied. In particular, the stable trapping of Xe+ was demonstrated for the first time, and the experimental developments that led to this are discussed. The work in this thesis represents significant progress towards studying the reaction of tunable-energy ND3 in the |j,mk> = |1,−1> quantum state with cold Xe+ ions. Ion-molecule reactions utilising ND3 molecules electrostatically guided through the Stark decelerator were performed. It was observed that the main source of error in these experiments was in the calculation of the initial number of Xe+ ions that had been sympathetically cooled into the Coulomb crystal. The sensitivity of the crystal morphology to the number of Xe+ ions was evaluated using molecular dynamics simulations. Strategies have been developed to reduce this uncertainty in future studies. In addition to experimental work, the theory of low temperature ion-molecule reactions has been developed further. The temperature at which classical and quantum mechanical calculations diverge due to purely statistical effects has been investigated using different model intermolecular potentials, for closed-shell and open-shell species, and in the ground and rotationally excited states. From the results of these calculations, several promising candidate reactions have been suggested that might exhibit statistical quantum behaviour at experimentally achievable temperatures.
The recent development of a range of techniques for producing cold atoms and molecules at very low translational temperatures T < or = 1 K has provided the opportunity to investigate collisional processes in a new physical regime. We have recently presented a new experimental method to study low-temperature reactive collisions between translationally cold ions and neutral molecules (S. Willitsch et al., Phys. Rev. Lett. 2008, 100, 043203). Our technique relies on the combination of a quadrupole-guide velocity selector for the generation of translationally cold neutral molecules with a facility to produce ordered structures of cold ions (Coulomb crystals) by laser cooling in a linear quadrupole ion trap. The strong localisation of the ions in the trap in combination with the high sensitivity of laser-induced-fluorescence detection enabled us to study chemical reactions on the single-particle level, down to temperatures of T approximately 1 K. In the current paper, we present a detailed characterisation of the scope and limitations of this method based on our study of the reaction between laser-cooled Ca+ ions and velocity-selected CH3F molecules. The properties of our cold-neutrals source and the dependence of the measured rate constant on the shape of the Coulomb crystals, trapping and laser-cooling parameters are discussed. An extension of our technique for the study of low-temperature reactions with sympathetically cooled molecular ions (translational temperature T > 10 mK) is presented and first results on the charge-transfer reaction between OCS+ and ND3 are discussed. Finally, perspectives for further developments of our method are explored.
This thesis describes the development and demonstration of techniques for the study of ion-neutral reactive collisions at low temperatures conducted using two unique experimental apparatuses comprising radio-frequency Paul traps. One apparatus combines a Stark decelerator with a Paul trap; the other apparatus features a buffer gas cell interfaced with a Paul trap through an electrostatic quadrupole guide. A novel ion trap time-of-flight mass spectrometer has been introduced and characterised. This apparatus is designed to detect the ion products of reactive collisions at low temperatures (< 10 K). This detection approach affords excellent detection efficiency and is broadly applicable to all ion-molecule reactions that one could study within a linear Paul ion trap. A proof-of-principle reaction between xenon ions and neutral ammonia isotopologues is examined to test the performance of the new detection set-up. With the goal of achieving full control over the reaction parameters, the amount of alignment retained by rotationally and translationally cold ammonia molecules exiting the electrostatic guide has been examined using (2 + 1) REMPI detection of the molecules with varying linear polarisation. Simulations suggests how modifications to the current setup will enable full orientation of the cooled molecules reaching the detection region to be achieved. Experiments on cold charge exchange reactions between sympathetically-cooled Xe+ and room temperature ammonia (NH3 and ND3) have been conducted within lasercooled Ca+ Coulomb crystals in a linear Paul ion trap. There is ongoing work to ascertain any difference in reactivity between NH3 and ND3 as the neutral reactant species. Preliminary data are discussed at a qualitative level, with the prospect of observing any isotope effect in this charge transfer process. Charge exchange reaction experiments using cold state-selected ammonia are discussed with the goal of establishing reaction rate constants at different collision energies.
The atom-ion hybrid system provides a new platform to study ultracold collisions and chemical reactions. To investigate chemical reactions in ultracold regimes, we combine neutral atoms in an optical trap and ions in a Paul trap to construct an atom-ion hybrid system. Here we introduce our recent work on ultracold elastic/inelastic collisions at a single atom level with a state-by-state manner. From quantitative discussions on the collision’s cross-sections, we clarified the microscopic collisional mechanisms.
A hybrid trap was developed to confine neutral molecules and molecular ions. We demonstrated the long-term trapping of Stark-decelerated OH radicals in the X 2Pi3/2 (v = 0, J = 3/2, MJ = 3/2, f) state in a permanent magnetic trap. The trap environment was cryogenically cooled to a temperature of 17 K in order to efficiently suppress black-body-radiation-induced pumping of the molecules out of trappable quantum states and collisions with residual background gas molecules which usually limit the trap lifetimes. The cold molecules were kept confined on timescales approaching minutes, an improvement of up to two orders of magnitude compared to room-temperature experiments, at translational temperatures on the order of 25 mK. A cryogenic ion trap was built and laser cooled Ca+ ions were confined. This ion trap can be used to confine sympathetically cooled molecular ions such as N+2or H2O+. Furthermore, a mechanism to superimpose both trap centers by moving the permanent magnets from the magnetic trap over the ion trap was developed. Both traps were characterized and their functionality was proven. The challenges of lasercooling in the strong magnetic field gradients were discussed. The present results pave the way for investigations of cold collisions and reactions with very small reaction rates between molecular ions and neutral molecules, for new avenues for the production of ultracold molecules via sympathetic cooling and for the realization of new forms of hybrid matter with co-trapped atoms or ions.
The atom-ion hybrid system provides us with new platform to study ultracold collisions and chemical reactions, which play important role in quantum simulations, quantum information processing utilizing atom-ion interactions. To investigate chemical reactions in an ultracold regime, we start with neutral atoms trapped in an optical dipole trap and ions in a linear Paul trap, and combine them together to construct a hybrid system. Here we introduce our recent work on ultracold elastic/inelastic collisions at a single atom level with a state-by-state manner in our atom-ion hybrid system. From the quantitative discussion on the collision cross sections, the microscopic collisional mechanisms have been clarified.