Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

The European Physical Journal D

High-precision measurement of tiny difference frequency via weak value amplification

Zhiyuan Wang, Zijing Zhang, Yuan Zhe Zhao

Published Sep 1, 2021• 1 citation
Publisher
DOI
10.1140/epjd/s10053-021-00245-x

Related papers

High-precision measurement of tiny Doppler frequency shifts based on quantum weak measurement with energy recycling

Zhiyuan Wang, Zijing Zhang, Yuan Zhe Zhao

The European Physical Journal Plus•Aug 1, 2021•2 citations

Simultaneously precise estimations of phase and amplitude variations based on weak-value amplification

Lan E Luo, Linguo Xie, Jiangdong Qiu +6 more

In this paper, we theoretically and experimentally present a precision method to simultaneously estimate the phase and amplitude variations of light based on the weak-value amplification. We demonstrate that the imaginary and real components of the weak-value correspond to the amplification of the phase and amplitude variations, respectively. If both the phase and the amplitude are varied, the phase measurement using the imaginary weak-value is not influenced by the amplitude shift and the amplitude measurement using the real weak value is not influenced by the phase shift. Thus, the tiny changes of the phase and amplitude of light can be obtained simultaneously with different post-selections, and the measurement precision reaches ∼10−6 rad. These findings may be favorable for highly sensitive optical polarization-dependent effects, including optical activity and magneto-optic effects.

Applied Physics Letters•Mar 18, 2019•27 citations

Progress and perspectives on weak-value amplification

Liang Xu, Lijian Zhang

arXiv:2407.10087•Progress in Quantum Electronics•Jun 8, 2024•16 citations

Realization of ultra-small stress birefringence detection with weak-value amplification technique

Yongsheng Wang, Shizhen Chen, Shuangchun Wen +1 more

How to realize the detection of tiny birefringence is an important but challenging issue for investigations and applications in optics. In weak measurements, weak-value amplification has been widely applied to the precise estimation of time delay. Here, we show that the linear amplification in weak measurements has the potential to outperform standard weak-value amplification for ultra-small parameter characterization. The higher measurement accuracy in the linear amplification enables us to achieve a measurement of stress-induced birefringence with a high resolution of 5×10−10. Compared with existing methods, the accuracy based on weak measurements for birefringence detection can improve two orders of magnitude. Our method may have important applications in a variety of fields involving the precise measurement of time delay or birefringence.

Applied Physics Letters•Apr 19, 2021•20 citations

Optimal signal amplification by weak measurement

友紀 須佐, Yuki Susa

•Sep 1, 2012•0 citations

Weak Measurements in Nano-optics

Niladri Modak, Ankit Kumar Singh, Shyamal Guchhait +3 more

Background: Weak measurement involves weak coupling between the system and the measuring device (pointer) enables large amplification and high precision measurement of small physical parameters. The outcome of this special measurement procedure involving nearly mutually orthogonal pre- and post-selection of states in such weakly interacting systems leads to weak value that can become exceedingly large and lie outside the eigenvalue spectrum of the measured observable. This unprecedented ability of weak value amplification of small physical parameters has been successfully exploited for various metrological applications in the optical domain and beyond. Even though it is a quantum mechanical concept, it can be understood using the classical electromagnetic theory of light and thus can be realized in classical optics. Objective: Here, we briefly review the basic concepts of weak measurement and weak value amplification, provide illustrative examples of its implementation in various optical domains. The applications involve measuring ultra-sensitive beam deflections, high precision measurements of angular rotation, phase shift, temporal shift, frequency shift and so forth, and expand this extraordinary concept in the domain of nano-optics and plasmonics. Methods: In order to perform weak value amplification, we have used Gaussian beam and spectral response as the pointer subsequently. The polarization state associated with the pointer is used as pre and post-selection device. Results: We reveal the weak value amplification of sub-wavelength optical effects namely the Goos-Hänchen shift and the spin hall shift. Further, we demonstrate weak measurements using spectral line shape of resonance as a natural pointer, enabling weak value amplification beyond the conventional limit, demonstrating natural weak value amplification in plasmonic Fano resonances and so forth. The discussed concepts could have useful implications in various nano-optical systems to amplify tiny signals or effects. Conclusion: The emerging prospects of weak value amplification towards the development of novel optical weak measurement devices for metrological applications are extensively discussed.

Current Nanomaterials•Jul 24, 2020•6 citations
In this paper, we theoretically and experimentally present a precision method to simultaneously estimate the phase and amplitude variations of light based on the weak-value amplification. We demonstrate that the imaginary and real components of the weak-value correspond to the amplification of the phase and amplitude variations, respectively. If both the phase and the amplitude are varied, the phase measurement using the imaginary weak-value is not influenced by the amplitude shift and the amplitude measurement using the real weak value is not influenced by the phase shift. Thus, the tiny changes of the phase and amplitude of light can be obtained simultaneously with different post-selections, and the measurement precision reaches ∼10−6 rad. These findings may be favorable for highly sensitive optical polarization-dependent effects, including optical activity and magneto-optic effects.
How to realize the detection of tiny birefringence is an important but challenging issue for investigations and applications in optics. In weak measurements, weak-value amplification has been widely applied to the precise estimation of time delay. Here, we show that the linear amplification in weak measurements has the potential to outperform standard weak-value amplification for ultra-small parameter characterization. The higher measurement accuracy in the linear amplification enables us to achieve a measurement of stress-induced birefringence with a high resolution of 5×10−10. Compared with existing methods, the accuracy based on weak measurements for birefringence detection can improve two orders of magnitude. Our method may have important applications in a variety of fields involving the precise measurement of time delay or birefringence.
Background: Weak measurement involves weak coupling between the system and the measuring device (pointer) enables large amplification and high precision measurement of small physical parameters. The outcome of this special measurement procedure involving nearly mutually orthogonal pre- and post-selection of states in such weakly interacting systems leads to weak value that can become exceedingly large and lie outside the eigenvalue spectrum of the measured observable. This unprecedented ability of weak value amplification of small physical parameters has been successfully exploited for various metrological applications in the optical domain and beyond. Even though it is a quantum mechanical concept, it can be understood using the classical electromagnetic theory of light and thus can be realized in classical optics. Objective: Here, we briefly review the basic concepts of weak measurement and weak value amplification, provide illustrative examples of its implementation in various optical domains. The applications involve measuring ultra-sensitive beam deflections, high precision measurements of angular rotation, phase shift, temporal shift, frequency shift and so forth, and expand this extraordinary concept in the domain of nano-optics and plasmonics. Methods: In order to perform weak value amplification, we have used Gaussian beam and spectral response as the pointer subsequently. The polarization state associated with the pointer is used as pre and post-selection device. Results: We reveal the weak value amplification of sub-wavelength optical effects namely the Goos-Hänchen shift and the spin hall shift. Further, we demonstrate weak measurements using spectral line shape of resonance as a natural pointer, enabling weak value amplification beyond the conventional limit, demonstrating natural weak value amplification in plasmonic Fano resonances and so forth. The discussed concepts could have useful implications in various nano-optical systems to amplify tiny signals or effects. Conclusion: The emerging prospects of weak value amplification towards the development of novel optical weak measurement devices for metrological applications are extensively discussed.