Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Bulletin of the American Physical Society

Quantum Synchronization in Nitrogen-Vacancy Centers in Diamonds

Pronoy Das, Agam Verma, Parvinder Solanki, Abhishek Kejriwal, Shreyas Chandgothia, Sai Vinjanampathy, Kasturi Saha

Published Mar 16, 2021• 0 citations
OpenAlex

Related papers

Low-Field J-Coupling Spectroscopy Measured with a Diamond Nitrogen Vacancy Spectrometer

Stephen J. DeVience, John W. Blanchard, Camille G. McDonnell +1 more

Nitrogen vacancy centers in diamond (NVs) are point defects well suited to quantum sensing of magnetic fields. NV spin states can be initialized and read out optically with high spatial resolution, enabling detection of pL-scale volumes of nuclear spins. Using Coherently Averaged Synchronized Readout (CASR), standard NMR spectroscopy techniques such as free decay, spin echo, and PGSE have been performed with Hz-scale spectral resolution using NV-diamond sensors. However, using NV detection for conventional high-resolution NMR at multi-tesla fields is challenging due to the need to manipulate NV electronic spins at resonance frequencies 100 GHz or higher. Low-field J-coupling spectroscopy provides an alternative path to chemical resolution in a regime more easily accessible to NVs. Here, we demonstrate homonuclear and heteronuclear J-coupling spectroscopy using an NV-NMR spectrometer based on permanent magnets operating at $\sim$890 kHz proton Larmor frequency (bias magnetic field $\sim$21 mT). This field strength enables chemical characterization based on J-coupling using sequences such as Synchronized Echo (SyncE) and Spin-Echo Double Resonance (SEDOR), which do not require the strong chemical shift dispersion and pristine field homogeneity of high-field NMR. The frequency range is easily detected by NVs using standard XY dynamical decoupling sequences and is well-suited for applying Overhauser DNP, which can boost proton signal by two orders of magnitude. We acquire initial NV-NMR measurements of T$_1$, T$_2$, and Overhauser DNP in glycerol before advancing to SEDOR spectroscopy of methanol-$^{13}$C and a methanol-$^{13}$C/acetonitrile-2-$^{13}$C mixture at sample volumes $\sim$50 pL, in which we demonstrate measurement of $^1J_\text{CH}$ couplings and resolution between species. We also acquire a homonuclear J-coupling spectrum of a natural-abundance propylene carbonate sample.

physics.chem-phCross-listedarXiv:2610.24815•Oct 20, 2026

Quantum information processing with nitrogen vacancy centers in diamonds

Lucas Tsunaki, Sérgio Ricardo Muniz

•Jan 1, 2020•0 citations

Toward Quantum Non-demolition of nitrogen-vacancy centers in diamond

J. S. Hodges, Liang Jiang, Jeronimo R. Maze +1 more

Bulletin of the American Physical Society•May 23, 2009•0 citations

Nitrogen-Terminated Diamond Surface for Nanoscale NMR by Shallow Nitrogen-Vacancy Centers

Sora Kawai, Hayate Yamano, Takahiro Sonoda +18 more

Abstract The nitrogen-vacancy (NV) center in diamond is the most promising candidate for quantum sensing because of its beneficial properties. For quantum-sensing applications, a shallow NV center is critical for approximating the sensing target on a diamond surface. Such shallow NV centers are strongly affected by the diamond surface termination. The properties of shallow NV centers in hydrogen-, oxygen-, and fluorine-terminated diamond have been well studied. In recent years, silicon-terminated diamond has also been investigated; however, the effect of silicon-terminated diamond on the properties of shallow NV centers remains unclear. Recently, the suitability of nitrogen-terminated diamond for shallow NV centers has been theoretically and experimentally examined; however, quantum sensing has not yet been performed. In this work, we evaluated the effect of silicon and nitrogen termination on shallow NV centers. The negatively charged state of shallow NV centers was unstable below silicon termination. In contrast, the properties of shallow NV centers in nitrogen-terminated diamond were satisfactory for quantum sensing and enabled 1H NMR detection. Our results are in good agreement with previous reports on silicon and nitrogen terminations and provide the perspective that the stability of shallow NV centers highly depends on the polarity of electron affinity of the diamond surface.

The Journal of Physical Chemistry C•Jan 24, 2019•98 citations

Structures in diamond for optical manipulation of nitrogen-vacancy centers

Charles Santori, Kai‐Mei C. Fu, Paul E. Barclay +1 more

We describe research on new optical structures in diamond for quantum information and sensing applications based on the nitrogen-vacancy (NV) center. Results include etching experiments that reveal the vertical distribution of NV centers produced by ion implantation and annealing, and gallium phosphide waveguides fabricated on diamond with evanescent coupling to NV centers close to the diamond surface.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Dec 29, 2008•0 citations

Quantum computation based on nitrogen-vacancy center in diamond

Pengfei Wang, Fazhan Shi, Du Jiangfeng

•May 31, 2014•0 citations
Nitrogen vacancy centers in diamond (NVs) are point defects well suited to quantum sensing of magnetic fields. NV spin states can be initialized and read out optically with high spatial resolution, enabling detection of pL-scale volumes of nuclear spins. Using Coherently Averaged Synchronized Readout (CASR), standard NMR spectroscopy techniques such as free decay, spin echo, and PGSE have been performed with Hz-scale spectral resolution using NV-diamond sensors. However, using NV detection for conventional high-resolution NMR at multi-tesla fields is challenging due to the need to manipulate NV electronic spins at resonance frequencies 100 GHz or higher. Low-field J-coupling spectroscopy provides an alternative path to chemical resolution in a regime more easily accessible to NVs. Here, we demonstrate homonuclear and heteronuclear J-coupling spectroscopy using an NV-NMR spectrometer based on permanent magnets operating at $\sim$890 kHz proton Larmor frequency (bias magnetic field $\sim21mT).ThisfieldstrengthenableschemicalcharacterizationbasedonJ−couplingusingsequencessuchasSynchronizedEcho(SyncE)andSpin−EchoDoubleResonance(SEDOR),whichdonotrequirethestrongchemicalshiftdispersionandpristinefieldhomogeneityofhigh−fieldNMR.ThefrequencyrangeiseasilydetectedbyNVsusingstandardXYdynamicaldecouplingsequencesandiswell−suitedforapplyingOverhauserDNP,whichcanboostprotonsignalbytwoordersofmagnitude.WeacquireinitialNV−NMRmeasurementsofT21 mT). This field strength enables chemical characterization based on J-coupling using sequences such as Synchronized Echo (SyncE) and Spin-Echo Double Resonance (SEDOR), which do not require the strong chemical shift dispersion and pristine field homogeneity of high-field NMR. The frequency range is easily detected by NVs using standard XY dynamical decoupling sequences and is well-suited for applying Overhauser DNP, which can boost proton signal by two orders of magnitude. We acquire initial NV-NMR measurements of T21mT).ThisfieldstrengthenableschemicalcharacterizationbasedonJ−couplingusingsequencessuchasSynchronizedEcho(SyncE)andSpin−EchoDoubleResonance(SEDOR),whichdonotrequirethestrongchemicalshiftdispersionandpristinefieldhomogeneityofhigh−fieldNMR.ThefrequencyrangeiseasilydetectedbyNVsusingstandardXYdynamicaldecouplingsequencesandiswell−suitedforapplyingOverhauserDNP,whichcanboostprotonsignalbytwoordersofmagnitude.WeacquireinitialNV−NMRmeasurementsofT_1,T, T,T_2,andOverhauserDNPinglycerolbeforeadvancingtoSEDORspectroscopyofmethanol−, and Overhauser DNP in glycerol before advancing to SEDOR spectroscopy of methanol-,andOverhauserDNPinglycerolbeforeadvancingtoSEDORspectroscopyofmethanol−^{13}Candamethanol−C and a methanol-Candamethanol−^{13}C/acetonitrile−2−C/acetonitrile-2-C/acetonitrile−2−^{13}$C mixture at sample volumes $\sim$50 pL, in which we demonstrate measurement of 1JCH^1J_\text{CH}1JCH​ couplings and resolution between species. We also acquire a homonuclear J-coupling spectrum of a natural-abundance propylene carbonate sample.
Abstract The nitrogen-vacancy (NV) center in diamond is the most promising candidate for quantum sensing because of its beneficial properties. For quantum-sensing applications, a shallow NV center is critical for approximating the sensing target on a diamond surface. Such shallow NV centers are strongly affected by the diamond surface termination. The properties of shallow NV centers in hydrogen-, oxygen-, and fluorine-terminated diamond have been well studied. In recent years, silicon-terminated diamond has also been investigated; however, the effect of silicon-terminated diamond on the properties of shallow NV centers remains unclear. Recently, the suitability of nitrogen-terminated diamond for shallow NV centers has been theoretically and experimentally examined; however, quantum sensing has not yet been performed. In this work, we evaluated the effect of silicon and nitrogen termination on shallow NV centers. The negatively charged state of shallow NV centers was unstable below silicon termination. In contrast, the properties of shallow NV centers in nitrogen-terminated diamond were satisfactory for quantum sensing and enabled 1H NMR detection. Our results are in good agreement with previous reports on silicon and nitrogen terminations and provide the perspective that the stability of shallow NV centers highly depends on the polarity of electron affinity of the diamond surface.