Conference on Lasers and Electro-Optics

Fiber-Optic Quantum Sensors for Applications in Micromagnetics and Thermal Imaging

Sean M. Blakley, Ilya V. Fedotov, Xiaohan Liu, Christapher Vincent, Xinghua Liu, Alexey V. Akimov, Philip Hemmer, Aleksei M. Zheltikov

Published Jan 1, 2021• 0 citations
Publisher

Abstract

High-resolution thermal and magnetic vector gradient imaging is demonstrated using diamond quantum sensors in a microstructured fiber probe platform. These sensors are capable of in situ magnetic field and temperature measurements with 160 pT / Hz and 25 mK / Hz sensitivities.
DOI
10.1364/cleo_si.2021.sw2i.4

Related papers

Multimodal Fiber-Optic Quantum Sensing with Defect Centers in Diamond

Sean M. Blakley, Ilya V. Fedotov, Christapher Vincent +5 more

We have developed microresolution quantum sensors by incorporating diamond color-centers into microstructured optical fibers. These sensors are capable of in situ magnetic field and temperature measurements with 160 @@pT/√ Hz and 25 mK/√ Hz sensi tivities

OSA Quantum 2.0 Conference•Jan 1, 2020•0 citations

High-resolution magnetic field imaging with a nitrogen-vacancy diamond sensor integrated with a photonic-crystal fiber

И. В. Федотов, Sean M. Blakley, Evgenii E. Serebryannikov +3 more

We demonstrate high-resolution magnetic field imaging with a scanning fiber-optic probe which couples nitrogen-vacancy (NV) centers in diamond to a high-numerical-aperture photonic-crystal fiber integrated with a two-wire microwave transmission line. Magnetic resonance excitation of NV centers driven by the microwave field is read out through optical interrogation through the photonic-crystal fiber to enable high-speed, high-sensitivity magnetic field imaging with sub 30 μm spatial resolution.

Optics Letters•Jan 22, 2016•51 citations

Microscale fiber-integrated vector magnetometer with on-tip field biasing using N-V ensembles in diamond microcrystals

Jonas Homrighausen, Frederik Hoffmann, Jens Pogorzelski +2 more

In quantum sensing of magnetic fields, ensembles of nitrogen-vacancy centers in diamond offer high sensitivity, high bandwidth and outstanding spatial resolution while operating in harsh environments. Moreover, the orientation of defect centers along four crystal axes forms an intrinsic coordinate system, enabling vector magnetometry within a single diamond crystal. While most vector magnetometers rely on a known bias magnetic field for full recovery of three-dimensional (3D) field information, employing external 3D Helmholtz coils or permanent magnets results in bulky, laboratory-bound setups, impeding miniaturization of the device. Here, a novel approach is presented that utilizes a fiber-integrated microscale coil at the fiber tip to generate a localized uniaxial magnetic field. The same fiber-tip coil is used in parallel for spin control by combining dc and microwave signals in a bias tee. To implement vector magnetometry using a uniaxial bias field, the orientation of the diamond crystal is preselected and then fully characterized by rotating a static magnetic field in three planes of rotation. The measurement of vector magnetic fields in the full solid angle is demonstrated with a shot-noise-limited sensitivity of 19.4 nT/Hz 1/2 and microscale spatial resolution while achieving a fiber sensor head cross section of less than 1 mm2

•Mar 18, 2026•0 citations

Microscale fiber-integrated vector magnetometer with on-tip field biasing using N - V ensembles in diamond microcrystals

Jonas Homrighausen, Frederik Hoffmann, Jens Pogorzelski +2 more

In quantum sensing of magnetic fields, ensembles of nitrogen-vacancy centers in diamond offer high sensitivity, high bandwidth and outstanding spatial resolution while operating in harsh environments. Moreover, the orientation of defect centers along four crystal axes forms an intrinsic coordinate system, enabling vector magnetometry within a single diamond crystal. While most vector magnetometers rely on a known bias magnetic field for full recovery of three-dimensional (3D) field information, employing external 3D Helmholtz coils or permanent magnets results in bulky, laboratory-bound setups, impeding miniaturization of the device. Here, a novel approach is presented that utilizes a fiber-integrated microscale coil at the fiber tip to generate a localized uniaxial magnetic field. The same fiber-tip coil is used in parallel for spin control by combining dc and microwave signals in a bias tee. To implement vector magnetometry using a uniaxial bias field, the orientation of the diamond crystal is preselected and then fully characterized by rotating a static magnetic field in three planes of rotation. The measurement of vector magnetic fields in the full solid angle is demonstrated with a shot-noise-limited sensitivity of 19.4 nT/Hz 1 / 2 and microscale spatial resolution while achieving a fiber sensor head cross section of less than 1 mm 2 . Published by the American Physical Society 2024

arXiv:2404.14089•Physical Review Applied•Sep 12, 2024•14 citations

Nanophotonic quantum magnetometry in a spin-dense diamond cavity

Nicholas J. Sorensen, Elham Zohari, Joshua S. Wildeman +3 more

Quantum sensors based on the nitrogen-vacancy (NV) center in diamond are leading platforms for high-sensitivity magnetometry with nanometer-scale resolution. State-of-the-art implementations, however, typically rely on bulky free-space optics or sacrifice spatial resolution to achieve high sensitivities. Here, we realize an integrated platform that overcomes this trade-off by fabricating monolithic whispering-gallery-mode cavities from a diamond chip containing a high density of NV centers and by evanescently coupling excitation to and photoluminescence from the cavity using a tapered optical fiber. Employing a lock-in-amplified Ramsey magnetometry scheme, we achieve a photon-shot-noise-limited DC sensitivity of $58\,\text{nT}/\sqrt{\text{Hz}}$---the best sensitivity reported to date for a nanofabricated cavity-based magnetometer. The microscopic cavity size enables micrometer-scale spatial resolution and low-power operation, while fiber-coupling provides a path to scalable on-chip integration. Arrays of such sensors could enable NV-NMR spectroscopy of sub-nanoliter samples, new magnetic-gradient imaging architectures, and compact biosensing platforms.

physics.opticsCross-listedarXiv:2511.19831•Physical Review Applied•Nov 26, 2025•3 citations

A robust fiber-based quantum thermometer coupled with nitrogen-vacancy centers

Shao-Chun Zhang, Yang Dong, Bo Du +7 more

The nitrogen-vacancy center in diamond has been broadly applied in quantum sensing since it is sensitive to different physical quantities. Meanwhile, it is difficult to isolate disturbances from unwanted physical quantities in practical applications. Here, we present a fiber-based quantum thermometer by tracking the sharp-dip in the zero-field optically detected magnetic resonance spectrum in a high-density nitrogen-vacancy ensemble. Such a scheme can not only significantly isolate the magnetic field and microwave power drift but also improve the temperature sensitivity. Thanks to its simplicity and compatibility in implementation and robustness, this quantum thermometer is then applied to the surface temperature imaging of an electronic chip with a sensitivity of 18mK/Hz. It thus paves the way to high sensitive temperature measurements in ambiguous environments.

arXiv:2004.04349•Review of Scientific Instruments•Apr 1, 2021•43 citations
In quantum sensing of magnetic fields, ensembles of nitrogen-vacancy centers in diamond offer high sensitivity, high bandwidth and outstanding spatial resolution while operating in harsh environments. Moreover, the orientation of defect centers along four crystal axes forms an intrinsic coordinate system, enabling vector magnetometry within a single diamond crystal. While most vector magnetometers rely on a known bias magnetic field for full recovery of three-dimensional (3D) field information, employing external 3D Helmholtz coils or permanent magnets results in bulky, laboratory-bound setups, impeding miniaturization of the device. Here, a novel approach is presented that utilizes a fiber-integrated microscale coil at the fiber tip to generate a localized uniaxial magnetic field. The same fiber-tip coil is used in parallel for spin control by combining dc and microwave signals in a bias tee. To implement vector magnetometry using a uniaxial bias field, the orientation of the diamond crystal is preselected and then fully characterized by rotating a static magnetic field in three planes of rotation. The measurement of vector magnetic fields in the full solid angle is demonstrated with a shot-noise-limited sensitivity of 19.4 nT/Hz 1/2 and microscale spatial resolution while achieving a fiber sensor head cross section of less than 1 mm2
In quantum sensing of magnetic fields, ensembles of nitrogen-vacancy centers in diamond offer high sensitivity, high bandwidth and outstanding spatial resolution while operating in harsh environments. Moreover, the orientation of defect centers along four crystal axes forms an intrinsic coordinate system, enabling vector magnetometry within a single diamond crystal. While most vector magnetometers rely on a known bias magnetic field for full recovery of three-dimensional (3D) field information, employing external 3D Helmholtz coils or permanent magnets results in bulky, laboratory-bound setups, impeding miniaturization of the device. Here, a novel approach is presented that utilizes a fiber-integrated microscale coil at the fiber tip to generate a localized uniaxial magnetic field. The same fiber-tip coil is used in parallel for spin control by combining dc and microwave signals in a bias tee. To implement vector magnetometry using a uniaxial bias field, the orientation of the diamond crystal is preselected and then fully characterized by rotating a static magnetic field in three planes of rotation. The measurement of vector magnetic fields in the full solid angle is demonstrated with a shot-noise-limited sensitivity of 19.4 nT/Hz 1 / 2 and microscale spatial resolution while achieving a fiber sensor head cross section of less than 1 mm 2 . Published by the American Physical Society 2024
Quantum sensors based on the nitrogen-vacancy (NV) center in diamond are leading platforms for high-sensitivity magnetometry with nanometer-scale resolution. State-of-the-art implementations, however, typically rely on bulky free-space optics or sacrifice spatial resolution to achieve high sensitivities. Here, we realize an integrated platform that overcomes this trade-off by fabricating monolithic whispering-gallery-mode cavities from a diamond chip containing a high density of NV centers and by evanescently coupling excitation to and photoluminescence from the cavity using a tapered optical fiber. Employing a lock-in-amplified Ramsey magnetometry scheme, we achieve a photon-shot-noise-limited DC sensitivity of 58 nT/Hz58\,\text{nT}/\sqrt{\text{Hz}}58nT/Hz​---the best sensitivity reported to date for a nanofabricated cavity-based magnetometer. The microscopic cavity size enables micrometer-scale spatial resolution and low-power operation, while fiber-coupling provides a path to scalable on-chip integration. Arrays of such sensors could enable NV-NMR spectroscopy of sub-nanoliter samples, new magnetic-gradient imaging architectures, and compact biosensing platforms.
The nitrogen-vacancy center in diamond has been broadly applied in quantum sensing since it is sensitive to different physical quantities. Meanwhile, it is difficult to isolate disturbances from unwanted physical quantities in practical applications. Here, we present a fiber-based quantum thermometer by tracking the sharp-dip in the zero-field optically detected magnetic resonance spectrum in a high-density nitrogen-vacancy ensemble. Such a scheme can not only significantly isolate the magnetic field and microwave power drift but also improve the temperature sensitivity. Thanks to its simplicity and compatibility in implementation and robustness, this quantum thermometer is then applied to the surface temperature imaging of an electronic chip with a sensitivity of 18mK/Hz. It thus paves the way to high sensitive temperature measurements in ambiguous environments.