Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of Physics D Applied Physics

A pulsed time-varying method for improving the spin readout efficiency of nitrogen vacancy centers

Tianzheng Liu, Jixing Zhang, Heng Yuan, Lixia Xu, Guodong Bian, Pengcheng Fan, Mingxin Li, Yuchen Liu, Sigang Xia, Chang Xu, Xing Mao Xiao

Published Jul 6, 2021• 5 citations
Publisher

Abstract

Abstract In this work, a time-varying pulse waveform spin readout sequence method is proposed to improve the spin readout efficiency of nitrogen-vacancy (NV) centers. The method consists of performing the readout signal-to-noise ratio (SNR) analysis via the construction of a rate equation model of the NV center. We demonstrate a superior performance from the time-varying waveform readout approach and focus on the role of the readout optimization in quantum measurements. A detailed comparison of the readout SNR of the time-varying waveform and conventional waveform is provided. We experimentally demonstrate that the readout SNR is increased by 8% by utilizing an optimized waveform. It is anticipated that the improved method will effectively benefit the sensing capability of NV center ensembles and provide support for high-precision measurements of solid systems.

DOI
10.1088/1361-6463/ac1191

Related papers

An improved spin readout for nitrogen vacancy center ensemble based on a maximum likelihood estimation method

Jixing Zhang, Lixia Xu, Tao Shi +7 more

Abstract In this work, a spin readout method using fluorescence dynamics is proposed based on maximum likelihood estimation (MLE) for improving the pulsed spin readout accuracy of nitrogen vacancy (NV) center. This estimation method can saturate the Cramér–Rao bound and enhance the photon-shot-noise-limited spin readout accuracy by 20% compared with conventional photon summation method. By employing a rate equation model of the NV center, the exact solution for the fluorescence dynamics is obtained. Additionally, according to the rate equation model’s relationship with fluorescence dynamics, spin, and pumping light power, a practical MLE readout scheme is furnished, which is able to distinguish spin readout information and classical noise. Compared with the conventional method, the classical noise suppression capability can be improved by 300 times. It is anticipated that the MLE method will effectively benefit sensing capability based on the NV centers even other scalable defect complexes in solid systems.

Journal of Physics D Applied Physics•Jul 21, 2020•14 citations

A Modified Spin Pulsed Readout Method for NV Center Ensembles Reducing Optical Noise

Jixing Zhang, Heng Yuan, Ning Zhang +6 more

The optical-noise-limited spin readout sensitivity determines the precision of quantum measurement based on nitrogen-vacancy (NV) center. This article investigates the fluorescence dynamics of NV centers by solving the optical rate equations and obtains complete theoretical formulas for the existing optical spin readout method. A transfer coefficient of optical noise to signal noise in the existing differential methods at different frequencies is introduced so as to analyze the optical noise suppression ability and the signal-to-noise ratio (SNR) results under the influence of photon shot noise and optical noise. To further reduce the influence of optical noise on the signal, we propose a modified method to minimize the transfer coefficient by adding a first-order compensation term. Compared with conventional methods, our modified method showed a twofold optical noise suppression ability improvement in the measurement frequency bandwidth. The experiment proves that the final SNR is increased by 43.4% for a long-term measurement. This modified method should lead to immediate improvements in pulsed spin readout of NV center ensembles without extra instrumentation for applications in magnetic field, electric field, and temperature measurements.

IEEE Transactions on Instrumentation and Measurement•Oct 29, 2019•26 citations

Online optimization for optical readout of a single electron spin in diamond

Xue Lin, Jingwei Fan, Runchuan Ye +4 more

The nitrogen-vacancy (NV) center in diamond has been developed as a promising platform for quantum sensing, especially for magnetic field measurements in the nano-tesla range with a nano-meter resolution. Optical spin readout performance has a direct effect on the signal-to-noise ratio (SNR) of experiments. In this work, we introduce an online optimization method to customize the laser waveform for readout. Both simulations and experiments reveal that our new scheme optimizes the optically detected magnetic resonance in NV center. The SNR of optical spin readout has been witnessed a 44.1% increase in experiments. In addition, we applied the scheme to the Rabi oscillation experiment, which shows an improvement of 46.0% in contrast and a reduction of 12.1% in mean deviation compared to traditional constant laser power SNR optimization. This scheme is promising to improve sensitivities for a wide range of NV-based applications in the future.

arXiv:2212.09214•Frontiers of Physics•Jan 12, 2023•7 citations

Optimal optical polarization of nitrogen-vacancy center with arbitrary waveform pulse

Jixing Zhang, Tianzheng Liu, Lixia, Xu +5 more

The current work proposes a method for pulsed-light polarization of nitrogen-vacancy (NV) center electron spin. To evaluate the influence of pulsed spin polarization, we establish a polarization evaluation index based on polarizability and polarization time. Master equation model are utilized to theoretically calculate the spin polarization dynamics under light excitation and the optimal polarization conditions for the conventional methods are obtained. A novel pulsed-light polarization method is proposed by changing the optical pumping rate in the master equation from a fixed value to a time variable and an optimal waveform for proposed method is demonstrated through the variational method, which can simultaneously achieve high polarizability and requires a short polarization time. Hence, the polarization evaluation index is improved by ~10%. Moreover, the proposed method is verified by a pulsed-laser experimental system based on an arbitrary waveform generator. The current report shall expand the application horizon of NV center based quantum sensing.

arXiv:2010.00954•Oct 2, 2020•1 citation

Efficient Real-Time Spin Readout of Nitrogen-Vacancy Centers Based on Bayesian Estimation

Jixing Zhang, Tianzheng Liu, Heng Yuan +8 more

This article introduces a real-time Bayesian estimation algorithm aimed at enhancing the spin readout efficiency of the nitrogen vacancy (NV) center ensemble in the diamond. By integrating both the prior probability distribution and the fluorescence likelihood function, stemming from the implementation of the NV center dynamics model, we offered an innovative solution to surpass the Cramer–Rao lower bound of the readout variance and improve the readout efficiency. The proposed real-time Bayesian estimation readout algorithm was experimentally realized by combining high-performance acquisition and processing hardware, and the Rabi oscillation experiments divulged that the signal-to-noise ratio of our approach was improved by 28.6%. This research illustrates the potential of the Bayesian estimation readout to enhance the NV ensemble's sensing capabilities and support the development of compact and scalable quantum sensors devices on a monolithic platform.

arXiv:2302.06310•IEEE Transactions on Industrial Electronics•Jan 24, 2024•8 citations

Purcell and Pulse Induced Impact for Measurement Based on Nitrogen-Vacancy Centers in Diamond

Lu Min Ji, Li Ye Zhao, Yu Hai Wang

Nitrogen-vacancy (NV) color centers in diamond serve as promising atomic spin systems for measurement applications requiring high accuracy and sensitivity. A key challenge in NV-based quantum sensing is minimizing spin readout noise to approach the standard quantum limit (SQL). Based on a six-level model, this work analyze the dependence of NV-based quantum sensing performance, including spin state readout noise and signal-to-noise ratio (SNR), on controllable parameters such as the Purcell factor and excitation laser pulse characteristics. This study demonstrates that a shorter excitation pulse duration results in a higher saturation value of ground-state spin polarization, while the total time required for the polarization process remains constant. Additionally, the spin readout noise does not improve monotonically with decreasing excitation pulse duration; instead, it initially decreases and subsequently increases as the pulse duration varies. The spin readout noise reaches its optimal level when the pulse duration is 3 ns. Furthermore, no positive correlation exists between the signal-to-noise ratio (SNR) and the Purcell factor, and there is also an optimal value for SNR. When the pulse duration ranges from 1 ns to 40 ns, the variation in SNR is relatively insignificant. This research offers a novel perspective for enhancing the performance of quantum sensing based on diamond defects, such as nitrogen-vacancy (NV) centers.

Key engineering materials•Nov 25, 2025•0 citations
Abstract In this work, a time-varying pulse waveform spin readout sequence method is proposed to improve the spin readout efficiency of nitrogen-vacancy (NV) centers. The method consists of performing the readout signal-to-noise ratio (SNR) analysis via the construction of a rate equation model of the NV center. We demonstrate a superior performance from the time-varying waveform readout approach and focus on the role of the readout optimization in quantum measurements. A detailed comparison of the readout SNR of the time-varying waveform and conventional waveform is provided. We experimentally demonstrate that the readout SNR is increased by 8% by utilizing an optimized waveform. It is anticipated that the improved method will effectively benefit the sensing capability of NV center ensembles and provide support for high-precision measurements of solid systems.
Abstract In this work, a spin readout method using fluorescence dynamics is proposed based on maximum likelihood estimation (MLE) for improving the pulsed spin readout accuracy of nitrogen vacancy (NV) center. This estimation method can saturate the Cramér–Rao bound and enhance the photon-shot-noise-limited spin readout accuracy by 20% compared with conventional photon summation method. By employing a rate equation model of the NV center, the exact solution for the fluorescence dynamics is obtained. Additionally, according to the rate equation model’s relationship with fluorescence dynamics, spin, and pumping light power, a practical MLE readout scheme is furnished, which is able to distinguish spin readout information and classical noise. Compared with the conventional method, the classical noise suppression capability can be improved by 300 times. It is anticipated that the MLE method will effectively benefit sensing capability based on the NV centers even other scalable defect complexes in solid systems.
The optical-noise-limited spin readout sensitivity determines the precision of quantum measurement based on nitrogen-vacancy (NV) center. This article investigates the fluorescence dynamics of NV centers by solving the optical rate equations and obtains complete theoretical formulas for the existing optical spin readout method. A transfer coefficient of optical noise to signal noise in the existing differential methods at different frequencies is introduced so as to analyze the optical noise suppression ability and the signal-to-noise ratio (SNR) results under the influence of photon shot noise and optical noise. To further reduce the influence of optical noise on the signal, we propose a modified method to minimize the transfer coefficient by adding a first-order compensation term. Compared with conventional methods, our modified method showed a twofold optical noise suppression ability improvement in the measurement frequency bandwidth. The experiment proves that the final SNR is increased by 43.4% for a long-term measurement. This modified method should lead to immediate improvements in pulsed spin readout of NV center ensembles without extra instrumentation for applications in magnetic field, electric field, and temperature measurements.
The nitrogen-vacancy (NV) center in diamond has been developed as a promising platform for quantum sensing, especially for magnetic field measurements in the nano-tesla range with a nano-meter resolution. Optical spin readout performance has a direct effect on the signal-to-noise ratio (SNR) of experiments. In this work, we introduce an online optimization method to customize the laser waveform for readout. Both simulations and experiments reveal that our new scheme optimizes the optically detected magnetic resonance in NV center. The SNR of optical spin readout has been witnessed a 44.1% increase in experiments. In addition, we applied the scheme to the Rabi oscillation experiment, which shows an improvement of 46.0% in contrast and a reduction of 12.1% in mean deviation compared to traditional constant laser power SNR optimization. This scheme is promising to improve sensitivities for a wide range of NV-based applications in the future.
The current work proposes a method for pulsed-light polarization of nitrogen-vacancy (NV) center electron spin. To evaluate the influence of pulsed spin polarization, we establish a polarization evaluation index based on polarizability and polarization time. Master equation model are utilized to theoretically calculate the spin polarization dynamics under light excitation and the optimal polarization conditions for the conventional methods are obtained. A novel pulsed-light polarization method is proposed by changing the optical pumping rate in the master equation from a fixed value to a time variable and an optimal waveform for proposed method is demonstrated through the variational method, which can simultaneously achieve high polarizability and requires a short polarization time. Hence, the polarization evaluation index is improved by ~10%. Moreover, the proposed method is verified by a pulsed-laser experimental system based on an arbitrary waveform generator. The current report shall expand the application horizon of NV center based quantum sensing.
This article introduces a real-time Bayesian estimation algorithm aimed at enhancing the spin readout efficiency of the nitrogen vacancy (NV) center ensemble in the diamond. By integrating both the prior probability distribution and the fluorescence likelihood function, stemming from the implementation of the NV center dynamics model, we offered an innovative solution to surpass the Cramer–Rao lower bound of the readout variance and improve the readout efficiency. The proposed real-time Bayesian estimation readout algorithm was experimentally realized by combining high-performance acquisition and processing hardware, and the Rabi oscillation experiments divulged that the signal-to-noise ratio of our approach was improved by 28.6%. This research illustrates the potential of the Bayesian estimation readout to enhance the NV ensemble's sensing capabilities and support the development of compact and scalable quantum sensors devices on a monolithic platform.
Nitrogen-vacancy (NV) color centers in diamond serve as promising atomic spin systems for measurement applications requiring high accuracy and sensitivity. A key challenge in NV-based quantum sensing is minimizing spin readout noise to approach the standard quantum limit (SQL). Based on a six-level model, this work analyze the dependence of NV-based quantum sensing performance, including spin state readout noise and signal-to-noise ratio (SNR), on controllable parameters such as the Purcell factor and excitation laser pulse characteristics. This study demonstrates that a shorter excitation pulse duration results in a higher saturation value of ground-state spin polarization, while the total time required for the polarization process remains constant. Additionally, the spin readout noise does not improve monotonically with decreasing excitation pulse duration; instead, it initially decreases and subsequently increases as the pulse duration varies. The spin readout noise reaches its optimal level when the pulse duration is 3 ns. Furthermore, no positive correlation exists between the signal-to-noise ratio (SNR) and the Purcell factor, and there is also an optimal value for SNR. When the pulse duration ranges from 1 ns to 40 ns, the variation in SNR is relatively insignificant. This research offers a novel perspective for enhancing the performance of quantum sensing based on diamond defects, such as nitrogen-vacancy (NV) centers.