Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Design and characterization of wideband balanced homodyne detectors for quantum homodyne tomography

Erick Barrios Barocio

Published Jan 1, 2012• 0 citations
Publisher

Abstract

This thesis reports the realization and applications of a versatile wideband balanced homodyne detector operating in the time domain and intended for Quantum Optical Tomography. The detector can work with high repetition rate lasers used for the production and measurement of the electric field quadratures of quantum states of light. Full characterization of the detector by shot-noise measurements and by verifying its capability to reconstruct the density matrix and Wigner function of various states of interest is given. By overcoming photodiodes response mismatch, high frequency electronics issues and by choosing an appropriate optical set-up, a high level of common mode suppression (52.4dB) and a low electronic noise gave a shot-to-electronic noise ratio of I3dB for a Local Oscillator with 6.2 x 108 photons-per-pulse on a ~ 100MHz bandwidth. Results for the characterization of a single-photon Fock state are presented. An average efficiency of 56% was obtained for the generation/detection of the state.

DOI
10.11575/prism/4702

Related papers

Ultrasensitive pulsed, balanced homodyne detector: application to time-domain quantum measurements

Hauke Hansen, Thomas Aichele, Christian Hettich +4 more

A pulsed, balanced homodyne detector has been developed for precise measurement of the electric field quadratures of pulsed optical quantum states. A high level of common mode suppression (>85 dB) and low electronic noise (730 electrons per pulse) provide a signal-to-noise ratio of 14 dB for measurement of the quantum noise of individual pulses. Measurements at repetition rates as high as 1 MHz are possible. As a test, quantum tomography of the coherent state was performed, and the Wigner function and the density matrix were reconstructed with 99.5% fidelity. The detection system can be used for ultrarsensitive balanced detection in cw mode, e.g., for weak absorption measurements.

arXiv:quant-ph/0104084•Optics Letters•Nov 1, 2001•141 citations

Non-classical field characterization by high-frequency, time-domain quantum homodyne tomography

Alessandro Zavatta, Silvia Viciani, Marco Bellini

We report about the realization and the applications of an efficient pulsed optical homodyne apparatus operating in the time domain at the high repetition rates characteristic of commonly used mode-locked lasers for the analysis of quantum light states. We give a full characterization of our system by shot-noise measurements and by verifying its capability to work in a gated configuration at lower acquisition rates. We demonstrate the potential of this high-frequency time-domain detector by applying it to the reconstruction of the density matrix elements and of the Wigner functions of various field states by means of quantum tomography. Results are shown for the complete characterization of simple coherent states with low average photon number, of single-photon Fock states and of the so-called single-photon added coherent states, which result from the elementary excitation of a classical wave-like field. Wigner functions with negative values are observed for the non-classical states and an overall efficiency of about 60% is obtained for the generation/detection system.

Laser Physics Letters•Sep 26, 2005•34 citations

High-speed time-domain balanced homodyne detector for nanosecond optical field applications

Shanna Du, Zongyang Li, Wenyuan Liu +2 more

We present a high-speed time-domain shot-noise-limited balanced homodyne detector that is suitable for the detection of the quantum states of nanosecond pulsed optical fields. The detector can detect the quantum noise of individual nanosecond optical pulses at a repetition rate of 40 MHz and achieve a signal-to-noise ratio of above 14.5 dB at a local oscillator power of 9.9×107 photons per pulse. The stability of the detector is characterized via an Allan variance measurement, and superior stability is observed. The detector is especially applicable in the fields of quantum optics and quantum information, where high-speed time-domain detection of nanosecond pulsed optical field quadratures is required.

Journal of the Optical Society of America B•Feb 1, 2018•19 citations

Measurement and manipulation of quantum states of travelling light fields

Merlin Cooper

This thesis is concerned with the generation of non-classical quantum states of light, the photon-level manipulation of quantum states and the accurate tomography of both quantum states and quantum processes. In optics, quantum information can be encoded and processed in both discrete and continuous variables. Hybrid approaches combining for example homodyne detection with conditional state preparation and manipulation are gaining increasing prominence. The development and characterization of a time-domain balanced homodyne detector (BHD) is presented. The detector has a bandwidth of 80 MHz, a signal-to-noise ratio of 14.5 dB and an efficiency of 86% making it well-suited to pulse-to-pulse measurement of quantum optical states. The BHD is employed to perform quantum state tomography (QST) of non-classical multi-photon Fock states generated by spontaneous parametric down-conversion. A detailed investigation of the mode-matching between the local oscillator used for homodyne detection and the generated Fock states is presented. The one-, two- and three-photon Fock states are reconstructed with a combined preparation and detection efficiency exceeding 50%. Fock states have a number of applications in quantum state engineering, where non-classical ancilla states and conditional measurements enable photon-level manipulation of quantum states. Fock state filtration (FSF) is investigated - an example of a post-selected beam splitter which is a basic building block for many quantum state engineering protocols. A model is developed incorporating the effect of experimental imperfections. An experimental implementation of a Fock state filter is fully characterized by means of coherent-state quantum process tomography (QPT). The reconstructed process is found to be consistent with the model. The filter preferentially removes the single-photon component from an arbitrary input quantum state. Calibration of optical detectors in the quantum regime is discussed. Quantum detector tomography (QDT) is reviewed and contrasted with a new technique for performing QST with a calibrated detector known as the fitting of data patterns (FDP). The first experimental characterization of a BHD is performed by probing the detector with phase-averaged coherent states. The FDP method is shown to be applicable to the estimation of quantum processes, where a detector response is not assumed - thus demonstrating the versatility of the FDP approach as a new method in the quantum tomography toolbox.

•Jan 1, 2014•0 citations

High-stability time-domain balanced homodyne detector for ultrafast optical pulse applications

Merlin Cooper, Christoph Söller, Brian J. Smith

Low-noise, efficient, phase-sensitive time-domain optical detection is essential for foundational tests of quantum physics based on optical quantum states and the realization of numerous applications ranging from quantum key distribution to coherent classical telecommunications. Stability, bandwidth, efficiency, and signal-to-noise ratio are crucial performance parameters for effective detector operation. Here we present a high-bandwidth, low-noise, ultra-stable time-domain coherent measurement scheme based on balanced homodyne detection ideally suited to characterization of quantum and classical light fields in well-defined ultrashort optical pulse modes.

arXiv:1112.0875•Journal of Modern Optics•May 1, 2013•30 citations

Mediciones de ruido en un detector balanceado homodino para la reconstrucción de la función de Wigner de estados coherentes y de vacío

Samuel Esteban Sánchez Rodríguez

The Wigner function is a quasi-probability distribution of quantum states of light that describes the probability amplitude of any state through their marginal distribution. The Wigner function can be reconstructed through quantum tomography which uses the information obtained from light quadratures to reconstruct a 3d image of the Wigner function. Light quadratures can be obtained by means of balanced homodyne detection (BHD). BHD uses a controlled interference between the quantum field to be characterized and a local oscillator, which is a coherent source with well-defined frequency and phase. The main feature of a BHD is its ability to measure extremely small noise signals, even below the quantum vacuum limit for squezeed light. To obtain precise measurements in BHD it is necessary to characterize the noise sources in the electronics of the BHD such as Johnson noise and fundamental noises such as shot noise. To characterize the noise in the BHD, time based and frequency-based measurements were performed to find the quantum to classical noise ratio (QCNR). QCNR measures the capacity of the BHD to distinguish quantum noise. A high QCNR allows us to make reliable measurements of the light quadratures. For this project we developed a circuit based on the one presented by Lang et al. in low noise balanced homodyne detector for quantum noise measurements.

•Jan 27, 2026•0 citations
This thesis reports the realization and applications of a versatile wideband balanced homodyne detector operating in the time domain and intended for Quantum Optical Tomography. The detector can work with high repetition rate lasers used for the production and measurement of the electric field quadratures of quantum states of light. Full characterization of the detector by shot-noise measurements and by verifying its capability to reconstruct the density matrix and Wigner function of various states of interest is given. By overcoming photodiodes response mismatch, high frequency electronics issues and by choosing an appropriate optical set-up, a high level of common mode suppression (52.4dB) and a low electronic noise gave a shot-to-electronic noise ratio of I3dB for a Local Oscillator with 6.2 x 108 photons-per-pulse on a ~ 100MHz bandwidth. Results for the characterization of a single-photon Fock state are presented. An average efficiency of 56% was obtained for the generation/detection of the state.
A pulsed, balanced homodyne detector has been developed for precise measurement of the electric field quadratures of pulsed optical quantum states. A high level of common mode suppression (>85 dB) and low electronic noise (730 electrons per pulse) provide a signal-to-noise ratio of 14 dB for measurement of the quantum noise of individual pulses. Measurements at repetition rates as high as 1 MHz are possible. As a test, quantum tomography of the coherent state was performed, and the Wigner function and the density matrix were reconstructed with 99.5% fidelity. The detection system can be used for ultrarsensitive balanced detection in cw mode, e.g., for weak absorption measurements.
We report about the realization and the applications of an efficient pulsed optical homodyne apparatus operating in the time domain at the high repetition rates characteristic of commonly used mode-locked lasers for the analysis of quantum light states. We give a full characterization of our system by shot-noise measurements and by verifying its capability to work in a gated configuration at lower acquisition rates. We demonstrate the potential of this high-frequency time-domain detector by applying it to the reconstruction of the density matrix elements and of the Wigner functions of various field states by means of quantum tomography. Results are shown for the complete characterization of simple coherent states with low average photon number, of single-photon Fock states and of the so-called single-photon added coherent states, which result from the elementary excitation of a classical wave-like field. Wigner functions with negative values are observed for the non-classical states and an overall efficiency of about 60% is obtained for the generation/detection system.
We present a high-speed time-domain shot-noise-limited balanced homodyne detector that is suitable for the detection of the quantum states of nanosecond pulsed optical fields. The detector can detect the quantum noise of individual nanosecond optical pulses at a repetition rate of 40 MHz and achieve a signal-to-noise ratio of above 14.5 dB at a local oscillator power of 9.9×107 photons per pulse. The stability of the detector is characterized via an Allan variance measurement, and superior stability is observed. The detector is especially applicable in the fields of quantum optics and quantum information, where high-speed time-domain detection of nanosecond pulsed optical field quadratures is required.
This thesis is concerned with the generation of non-classical quantum states of light, the photon-level manipulation of quantum states and the accurate tomography of both quantum states and quantum processes. In optics, quantum information can be encoded and processed in both discrete and continuous variables. Hybrid approaches combining for example homodyne detection with conditional state preparation and manipulation are gaining increasing prominence. The development and characterization of a time-domain balanced homodyne detector (BHD) is presented. The detector has a bandwidth of 80 MHz, a signal-to-noise ratio of 14.5 dB and an efficiency of 86% making it well-suited to pulse-to-pulse measurement of quantum optical states. The BHD is employed to perform quantum state tomography (QST) of non-classical multi-photon Fock states generated by spontaneous parametric down-conversion. A detailed investigation of the mode-matching between the local oscillator used for homodyne detection and the generated Fock states is presented. The one-, two- and three-photon Fock states are reconstructed with a combined preparation and detection efficiency exceeding 50%. Fock states have a number of applications in quantum state engineering, where non-classical ancilla states and conditional measurements enable photon-level manipulation of quantum states. Fock state filtration (FSF) is investigated - an example of a post-selected beam splitter which is a basic building block for many quantum state engineering protocols. A model is developed incorporating the effect of experimental imperfections. An experimental implementation of a Fock state filter is fully characterized by means of coherent-state quantum process tomography (QPT). The reconstructed process is found to be consistent with the model. The filter preferentially removes the single-photon component from an arbitrary input quantum state. Calibration of optical detectors in the quantum regime is discussed. Quantum detector tomography (QDT) is reviewed and contrasted with a new technique for performing QST with a calibrated detector known as the fitting of data patterns (FDP). The first experimental characterization of a BHD is performed by probing the detector with phase-averaged coherent states. The FDP method is shown to be applicable to the estimation of quantum processes, where a detector response is not assumed - thus demonstrating the versatility of the FDP approach as a new method in the quantum tomography toolbox.
Low-noise, efficient, phase-sensitive time-domain optical detection is essential for foundational tests of quantum physics based on optical quantum states and the realization of numerous applications ranging from quantum key distribution to coherent classical telecommunications. Stability, bandwidth, efficiency, and signal-to-noise ratio are crucial performance parameters for effective detector operation. Here we present a high-bandwidth, low-noise, ultra-stable time-domain coherent measurement scheme based on balanced homodyne detection ideally suited to characterization of quantum and classical light fields in well-defined ultrashort optical pulse modes.
The Wigner function is a quasi-probability distribution of quantum states of light that describes the probability amplitude of any state through their marginal distribution. The Wigner function can be reconstructed through quantum tomography which uses the information obtained from light quadratures to reconstruct a 3d image of the Wigner function. Light quadratures can be obtained by means of balanced homodyne detection (BHD). BHD uses a controlled interference between the quantum field to be characterized and a local oscillator, which is a coherent source with well-defined frequency and phase. The main feature of a BHD is its ability to measure extremely small noise signals, even below the quantum vacuum limit for squezeed light. To obtain precise measurements in BHD it is necessary to characterize the noise sources in the electronics of the BHD such as Johnson noise and fundamental noises such as shot noise. To characterize the noise in the BHD, time based and frequency-based measurements were performed to find the quantum to classical noise ratio (QCNR). QCNR measures the capacity of the BHD to distinguish quantum noise. A high QCNR allows us to make reliable measurements of the light quadratures. For this project we developed a circuit based on the one presented by Lang et al. in low noise balanced homodyne detector for quantum noise measurements.