Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

IEEE photonics journal

High-Throughput Chiral Molecule Determination Based on Multi-Channel Weak Measurement

Lixuan Shi, Yang Xu, Zhen Qiao, Xin‐Hui Xing, Zhangyan Li, Chongqi Zhou, Suyi Zhong, Le Liu, Tian Guan, Yonghong He

Published Apr 6, 2021• 2 citations
Publisher

Abstract

A multi-channel high-throughput chiral molecule determination method based on weak value amplification (WVA) is proposed for the first time. This method can be used for high-throughput and high-precision determination of chiral molecule. Through the design of multi-channel weak measurement system, we realized the real-time, high-throughput, high-sensitivity and high-resolution detection of chiral molecules by selecting proper measurement states. In this work, we have realized a sensitivity of 11.8 nm/° and a resolution of 3.13 × 10-4° for measuring optical rotation. Moreover, the proposed method is successfully applied for detection of lactose content in milk samples. Furthermore, the system has the advantages of simple and robust real-time detection settings, strong stability, high measurement efficiency and good scalability. This method has important significance in clinical diagnosis, food safety and biological system.

DOI
10.1109/jphot.2021.3071267

Related papers

High-Precise Measurement of Optical Rotatory Dispersion Based on Weak Value Amplification

Jingyi Shao, Lan E Luo, Yu He +4 more

Chiroptical signals (generally very weak) play significant roles in chiral discrimination that bring great benefits in biochemistry, pharmacy, chemical, and so on. But, high-precise chiroptical detection is still a challenge. In this paper, a high-precise measurement of optical rotatory dispersion (ORD) based on weak value amplification (WVA) is presented. We proposed ORD detection method with parameter separation: by introducing complex coupling strength and dimensionless parameter “intensitiy contrast ratio” pointer, the ORD is only associated with the imaginary part of the weak value while circular dichroism (CD) is only associated with the real part. By designing a suitable WVA scheme, the ORD and CD can be measured separately. In the experiment, the reliability of the parameter separation method for ORD measurement is verified, and the precision reach the order of $10^{-6}$ rad. This method has a broad application prospect in biomedical sensing, medicine, chemical analysis and other fields.

IEEE photonics journal•Jul 7, 2021•15 citations

Estimation of optical rotation of chiral molecules with weak measurements

Xiaodong Qiu, Linguo Xie, Xiong Liu +3 more

From its beginning, the measurement of optical rotation (OR) is crucial for the analysis of chiral molecules in many fields. However, the precision measurement of a weak OR signal with conventional setup remains elusive. In this Letter, we experimentally propose a precision method to determine the OR of glucose and fructose based on weak measurements. By using the spin Hall effect of light (SHEL) as a probe, a nonlinear weak measurements model is established that is applicable beyond the Aharonov-Albert-Vaidman (AAV) limit. Due to the high sensitivity of weak measurements amplification with respect to the OR, a tremendous variation of the amplified beam displacement of the SHEL is observed, while the concentration of glucose and fructose is slightly changed.

Optics Letters•Aug 23, 2016•138 citations

Precise measurement of chiral spectrum in the ultraviolet band using weak measurement and a deep neural network model

Tingting Tang, Ying Gao, Yu He +7 more

Circular dichroism (CD) spectrum and optical rotation (OR) spectrum, crucial for understanding molecular properties and configurations, present challenges due to limited testing methods and equipment accuracy in the ultraviolet (UV) region. This study proposes a weak measurement system for chiral signals in varying concentrations in the ultraviolet range, optimized using a deep neural network (DNN) model. Introducing different post-selections to detect the circular dichroism spectrum and optical rotation spectrum separately, with contrast as a probe, it achieves a detection resolution of up to 10 −6 rad. Moreover, the fitted value of the training data can reach 0.9989, enhancing the prediction accuracy of chiral molecule concentrations. This method exhibits considerable promise for applications in chiral measurement and sensor technologies.

Optics Letters•Jul 8, 2024•4 citations

Realization of ultra-small stress birefringence detection with weak-value amplification technique

Yongsheng Wang, Shizhen Chen, Shuangchun Wen +1 more

How to realize the detection of tiny birefringence is an important but challenging issue for investigations and applications in optics. In weak measurements, weak-value amplification has been widely applied to the precise estimation of time delay. Here, we show that the linear amplification in weak measurements has the potential to outperform standard weak-value amplification for ultra-small parameter characterization. The higher measurement accuracy in the linear amplification enables us to achieve a measurement of stress-induced birefringence with a high resolution of 5×10−10. Compared with existing methods, the accuracy based on weak measurements for birefringence detection can improve two orders of magnitude. Our method may have important applications in a variety of fields involving the precise measurement of time delay or birefringence.

Applied Physics Letters•Apr 19, 2021•20 citations

Enhancing Interferometry Using Weak Value Amplification with Real Weak Values

Jing-Hui Huang, Kyle M. Jordan, Adetunmise C. Dada +2 more

We introduce an ultrasensitive interferometric protocol that combines weak value amplification (WVA) with traditional interferometry. This protocol WVA+interferometry uses weak value amplification of the relative delay between two paths to enhance interferometric sensitivity. As an example, we demonstrate a proof-of-principle experiment that achieves few-attosecond timing resolution (few nanometer path length resolution) with a double-slit interferometer using only common optical components. Since our example uses only the spatial shift of double-slit interference fringes, its precision is not limited by the timing resolution of the detectors but is instead limited by the fundamental shot noise associated with classical light and the diminished technical noise. We experimentally demonstrate that the signal-to-noise ratio can be improved by one to two orders of magnitude relative to a measurement that does not use WVA. Two key conclusions are drawn: (i) Most conventional interferometric techniques primarily rely on determining the path difference (time delay or longitudinal phase), with their precision constrained by technical noise. Our protocol offers a robust solution for minimizing the technical noise in traditional interferometry, with precision in principle approaching the shot-noise limit. (ii) Although WVA has achieved significant advancements in ultrasensitive longitudinal phase measurement, its applicability is constrained by the need for broad spectral bandwidths and high-resolution spectrometers. Contrary to previous assumptions, we demonstrate that quantum-limited WVA time delay measurements are achievable with narrow band light using real weak values. Thus, the cost-effectiveness and practicality of the proposed WVA+interferometry protocol using narrow band light broaden the scope of WVA applications. This protocol holds potential for broad applications in optical metrology, quantum optics and quantum information, biomedical imaging, and interferometric telescopes for astrophysics.

arXiv:2404.00531•Physical Review Letters•Feb 27, 2025•13 citations

High-sensitivity atomic magnetometer realized by weak-value-amplification effect

Shudong Lin, Junjian Tang, Ziqi Yuan +3 more

The weak-value-amplification (WVA) effect, which is also called weak measurement, has been developed extensively in various sensing systems. Here, we report the actual realization of the WVA effect in spin-exchange relaxation-free atomic magnetometer system, wherein the slight separation of transverse momentum of the probe light is amplified by introducing orthogonal pre- and post-selection states. A differential detector is used to obtain the transverse position of the probe light accurately in real time. The weak coupling of the magneto-optical interaction with atoms will be reflected in the differential signal. The WVA effect is observed and demonstrated directly and a high sensitivity of 8 fT/Hz is achieved. Also, we obtain the stable and distinct simulated magnetocardiography signal through our system. The present successful implementation of this probe method paves the way for further technical noise suppression and sensitivity improvement of quantum sensors.

Applied Physics Letters•Nov 6, 2023•15 citations
A multi-channel high-throughput chiral molecule determination method based on weak value amplification (WVA) is proposed for the first time. This method can be used for high-throughput and high-precision determination of chiral molecule. Through the design of multi-channel weak measurement system, we realized the real-time, high-throughput, high-sensitivity and high-resolution detection of chiral molecules by selecting proper measurement states. In this work, we have realized a sensitivity of 11.8 nm/° and a resolution of 3.13 × 10-4° for measuring optical rotation. Moreover, the proposed method is successfully applied for detection of lactose content in milk samples. Furthermore, the system has the advantages of simple and robust real-time detection settings, strong stability, high measurement efficiency and good scalability. This method has important significance in clinical diagnosis, food safety and biological system.
Chiroptical signals (generally very weak) play significant roles in chiral discrimination that bring great benefits in biochemistry, pharmacy, chemical, and so on. But, high-precise chiroptical detection is still a challenge. In this paper, a high-precise measurement of optical rotatory dispersion (ORD) based on weak value amplification (WVA) is presented. We proposed ORD detection method with parameter separation: by introducing complex coupling strength and dimensionless parameter “intensitiy contrast ratio” pointer, the ORD is only associated with the imaginary part of the weak value while circular dichroism (CD) is only associated with the real part. By designing a suitable WVA scheme, the ORD and CD can be measured separately. In the experiment, the reliability of the parameter separation method for ORD measurement is verified, and the precision reach the order of 10−610^{-6}10−6 rad. This method has a broad application prospect in biomedical sensing, medicine, chemical analysis and other fields.
From its beginning, the measurement of optical rotation (OR) is crucial for the analysis of chiral molecules in many fields. However, the precision measurement of a weak OR signal with conventional setup remains elusive. In this Letter, we experimentally propose a precision method to determine the OR of glucose and fructose based on weak measurements. By using the spin Hall effect of light (SHEL) as a probe, a nonlinear weak measurements model is established that is applicable beyond the Aharonov-Albert-Vaidman (AAV) limit. Due to the high sensitivity of weak measurements amplification with respect to the OR, a tremendous variation of the amplified beam displacement of the SHEL is observed, while the concentration of glucose and fructose is slightly changed.
Circular dichroism (CD) spectrum and optical rotation (OR) spectrum, crucial for understanding molecular properties and configurations, present challenges due to limited testing methods and equipment accuracy in the ultraviolet (UV) region. This study proposes a weak measurement system for chiral signals in varying concentrations in the ultraviolet range, optimized using a deep neural network (DNN) model. Introducing different post-selections to detect the circular dichroism spectrum and optical rotation spectrum separately, with contrast as a probe, it achieves a detection resolution of up to 10 −6 rad. Moreover, the fitted value of the training data can reach 0.9989, enhancing the prediction accuracy of chiral molecule concentrations. This method exhibits considerable promise for applications in chiral measurement and sensor technologies.
How to realize the detection of tiny birefringence is an important but challenging issue for investigations and applications in optics. In weak measurements, weak-value amplification has been widely applied to the precise estimation of time delay. Here, we show that the linear amplification in weak measurements has the potential to outperform standard weak-value amplification for ultra-small parameter characterization. The higher measurement accuracy in the linear amplification enables us to achieve a measurement of stress-induced birefringence with a high resolution of 5×10−10. Compared with existing methods, the accuracy based on weak measurements for birefringence detection can improve two orders of magnitude. Our method may have important applications in a variety of fields involving the precise measurement of time delay or birefringence.
We introduce an ultrasensitive interferometric protocol that combines weak value amplification (WVA) with traditional interferometry. This protocol WVA+interferometry uses weak value amplification of the relative delay between two paths to enhance interferometric sensitivity. As an example, we demonstrate a proof-of-principle experiment that achieves few-attosecond timing resolution (few nanometer path length resolution) with a double-slit interferometer using only common optical components. Since our example uses only the spatial shift of double-slit interference fringes, its precision is not limited by the timing resolution of the detectors but is instead limited by the fundamental shot noise associated with classical light and the diminished technical noise. We experimentally demonstrate that the signal-to-noise ratio can be improved by one to two orders of magnitude relative to a measurement that does not use WVA. Two key conclusions are drawn: (i) Most conventional interferometric techniques primarily rely on determining the path difference (time delay or longitudinal phase), with their precision constrained by technical noise. Our protocol offers a robust solution for minimizing the technical noise in traditional interferometry, with precision in principle approaching the shot-noise limit. (ii) Although WVA has achieved significant advancements in ultrasensitive longitudinal phase measurement, its applicability is constrained by the need for broad spectral bandwidths and high-resolution spectrometers. Contrary to previous assumptions, we demonstrate that quantum-limited WVA time delay measurements are achievable with narrow band light using real weak values. Thus, the cost-effectiveness and practicality of the proposed WVA+interferometry protocol using narrow band light broaden the scope of WVA applications. This protocol holds potential for broad applications in optical metrology, quantum optics and quantum information, biomedical imaging, and interferometric telescopes for astrophysics.
The weak-value-amplification (WVA) effect, which is also called weak measurement, has been developed extensively in various sensing systems. Here, we report the actual realization of the WVA effect in spin-exchange relaxation-free atomic magnetometer system, wherein the slight separation of transverse momentum of the probe light is amplified by introducing orthogonal pre- and post-selection states. A differential detector is used to obtain the transverse position of the probe light accurately in real time. The weak coupling of the magneto-optical interaction with atoms will be reflected in the differential signal. The WVA effect is observed and demonstrated directly and a high sensitivity of 8 fT/Hz is achieved. Also, we obtain the stable and distinct simulated magnetocardiography signal through our system. The present successful implementation of this probe method paves the way for further technical noise suppression and sensitivity improvement of quantum sensors.