Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physical Review A

Weak measurement with the peak-contrast-ratio pointer

Junfan Zhu, Zhaoxue Li, Yurong Liu, Yucheng Ye, Qian Ti, Zhiyou Zhang, Fuhua Gao

Published Mar 16, 2021• 19 citations
Publisher

Abstract

Weak measurement as a nonperturbative theory has been shown to be powerful in the fundamentals of quantum mechanics and high-precision metrology, in which the pointer is of great importance to parameter estimation and experimental design. In this work, we find that under the conditions of weak coupling and Gaussian meter, the probability distribution after the postselection follows a bimodal function and the peak contrast ratio (PCR) can be applied as a special pointer, which is different from the shift of mean value. To obtain the PCR, only two values corresponding to the two peaks in the distribution function are required. We theoretically present the relation of the PCR and parameters to be estimated, and then demonstrate it in an experiment. Weak measurement with the PCR pointer has the advantages of reducing the requirements of the apparatus and suppressing noise, which also provides a heuristic approach for studying weak measurement when the weak value is very large.

DOI
10.1103/physreva.103.032212

Related papers

High-Precision Multiparameter Weak Measurement with Hermite-Gaussian Pointer

Binke Xia, Jingzheng Huang, Chen Fang +2 more

The weak-value amplification technique has been proved to be useful for precision metrology in both theory and experiment. To explore the ultimate performance of weak-value amplification for multiparameter estimation, we investigate a general weak-measurement formalism with the assistance of the high-order Hermite-Gaussian (H-G) pointer and the quantum Fisher information matrix. Theoretical analysis shows that the ultimate precision of our scheme is improved by a factor of the square root of $2n+1$, where $n$ is the order of the Hermite-Gaussian mode. Moreover, the parameters' estimation precision can approach the precision limit with the maximum-likelihood estimation method and the homodyne method. We also present a proof-of-principle experimental setup to validate the H-G--pointer theory and explore its potential applications in precision metrology.

arXiv:2310.06605•Physical Review Applied•Mar 9, 2020•25 citations

Precise Measurement of Polarization Variation Using Weak Measurement With Double Pointers

Lan E Luo, Yu He, Junfan Zhu +3 more

In this paper, a weak measurement scheme with double pointers (mean value shift and intensity shift of the post-selected light) is presented to simultaneously measure the tiny polarization change (phase and amplitude) of light in a single experimental apparatus. Furthermore, rather than using charge-coupled-device (CCD) to measure the pointer shift, we use the two-channel photoreceiver combined with lock-in amplifier (LIA) to measure the intensities of a split-Gaussian mode in this work. In this way, we introduce two intensity contrast ratios (ICRs) as special pointers to characterize the mean value and intensity shifts. As a result, the measurement precision of the polarization rotation is on the order of magnitude of$\,10^{-7}rad$in the experiment. These findings provide a distinctive insight into the weak measurement and have important implications for the accurate measurement of complex optical parameters.

IEEE photonics journal•May 31, 2023•6 citations

Improving the Precision of Weak Measurements by Postselection Measurement

Shengshi Pang, Todd A. Brun

Postselected weak measurement is a useful protocol for amplifying weak physical effects. However, there has recently been controversy over whether it gives any advantage in precision. While it is now clear that retaining failed postselections can yield more Fisher information than discarding them, the advantage of postselection measurement itself still remains to be clarified. In this Letter, we address this problem by studying two widely used estimation strategies: averaging measurement results, and maximum likelihood estimation, respectively. For the first strategy, we find a surprising result that squeezed coherent states of the pointer can give postselected weak measurements a higher signal-to-noise ratio than standard ones while all standard coherent states cannot, which suggests that raising the precision of weak measurements by postselection calls for the presence of "nonclassicality" in the pointer states. For the second strategy, we show that the quantum Fisher information of postselected weak measurements is generally larger than that of standard weak measurements, even without using the failed postselection events, but the gap can be closed with a proper choice of system state.

arXiv:1409.2567•Physical Review Letters•Sep 15, 2015•128 citations

A Weak Value Amplification Scheme Based on Single-Particle Multi-Levels

Wenbo Su, Peng Wang, 吴春旺 +2 more

Abstract Weak measurements have many applications in the field of quantum information due to the peculiar properties of weak values. Quantum weak measurement can be performed by two particles or two degree of freedom of single particle. The former needs complex operations, the latter require the reconstruction of the motion state wavepacket, which consumes substantial quantum resources. This paper presents a novel weak measurement scheme that encodes multiple internal energy levels of a single particle into the measured system and the measuring pointer, while defining a finite-coupling postselected pointer ratio (FCPR). The FCPR obtained from this scheme enables both weak value amplification and rapid experimental results. To verify these advantages, we measured the FCPR using a trapped 40 Ca + experimental setup and monitored fluctuations of the laser power within the experimental system. The results show that our scheme can detect weaker laser power fluctuations, thus providing higher precision for laser power locking.

Chinese Physics B•Sep 15, 2026•0 citations

Weak Measurements in Nano-optics

Niladri Modak, Ankit Kumar Singh, Shyamal Guchhait +3 more

Background: Weak measurement involves weak coupling between the system and the measuring device (pointer) enables large amplification and high precision measurement of small physical parameters. The outcome of this special measurement procedure involving nearly mutually orthogonal pre- and post-selection of states in such weakly interacting systems leads to weak value that can become exceedingly large and lie outside the eigenvalue spectrum of the measured observable. This unprecedented ability of weak value amplification of small physical parameters has been successfully exploited for various metrological applications in the optical domain and beyond. Even though it is a quantum mechanical concept, it can be understood using the classical electromagnetic theory of light and thus can be realized in classical optics. Objective: Here, we briefly review the basic concepts of weak measurement and weak value amplification, provide illustrative examples of its implementation in various optical domains. The applications involve measuring ultra-sensitive beam deflections, high precision measurements of angular rotation, phase shift, temporal shift, frequency shift and so forth, and expand this extraordinary concept in the domain of nano-optics and plasmonics. Methods: In order to perform weak value amplification, we have used Gaussian beam and spectral response as the pointer subsequently. The polarization state associated with the pointer is used as pre and post-selection device. Results: We reveal the weak value amplification of sub-wavelength optical effects namely the Goos-Hänchen shift and the spin hall shift. Further, we demonstrate weak measurements using spectral line shape of resonance as a natural pointer, enabling weak value amplification beyond the conventional limit, demonstrating natural weak value amplification in plasmonic Fano resonances and so forth. The discussed concepts could have useful implications in various nano-optical systems to amplify tiny signals or effects. Conclusion: The emerging prospects of weak value amplification towards the development of novel optical weak measurement devices for metrological applications are extensively discussed.

Current Nanomaterials•Jul 24, 2020•6 citations

Optimization of parameter measurement precision with precoupling-assisted weak-value amplification

Manchao Zhang, Jie Zhang, Chun-Wang Wu +4 more

The weak-value amplification is extensively considered in precision metrology in order to achieve a higher sensitivity. Despite the practical benefits in amplifying small physical quantities, its metrological advantage still arouses a broad debate due to the low postselection probability of success. In this paper, by employing the quantum Fisher information metric, we show that the precision of estimating an unknown parameter can be improved by introducing a precoupling process with properly chosen interaction operators. We point out this result is credible for both real and imaginary weak values. By tracking the meter wave functions, we find this enhancement of estimation precision comes from a precoupling induced modulation of the meter wave function, thus the most sensitive regime with respect to the parameter is reached. In addition, the estimation error is investigated by considering the difference between the theoretical and estimated value. The analysis suggests that this kind of error can be effectively suppressed by averaging the estimations resulted from different initial meter states. These results are finally illustrated by an exact numerical simulation where the advantages of our proposal are displayed by the comparison to the standard weak-value amplification scheme.

Physical Review A•Apr 3, 2023•5 citations
Weak measurement as a nonperturbative theory has been shown to be powerful in the fundamentals of quantum mechanics and high-precision metrology, in which the pointer is of great importance to parameter estimation and experimental design. In this work, we find that under the conditions of weak coupling and Gaussian meter, the probability distribution after the postselection follows a bimodal function and the peak contrast ratio (PCR) can be applied as a special pointer, which is different from the shift of mean value. To obtain the PCR, only two values corresponding to the two peaks in the distribution function are required. We theoretically present the relation of the PCR and parameters to be estimated, and then demonstrate it in an experiment. Weak measurement with the PCR pointer has the advantages of reducing the requirements of the apparatus and suppressing noise, which also provides a heuristic approach for studying weak measurement when the weak value is very large.
The weak-value amplification technique has been proved to be useful for precision metrology in both theory and experiment. To explore the ultimate performance of weak-value amplification for multiparameter estimation, we investigate a general weak-measurement formalism with the assistance of the high-order Hermite-Gaussian (H-G) pointer and the quantum Fisher information matrix. Theoretical analysis shows that the ultimate precision of our scheme is improved by a factor of the square root of 2n+12n+12n+1, where nnn is the order of the Hermite-Gaussian mode. Moreover, the parameters' estimation precision can approach the precision limit with the maximum-likelihood estimation method and the homodyne method. We also present a proof-of-principle experimental setup to validate the H-G--pointer theory and explore its potential applications in precision metrology.
In this paper, a weak measurement scheme with double pointers (mean value shift and intensity shift of the post-selected light) is presented to simultaneously measure the tiny polarization change (phase and amplitude) of light in a single experimental apparatus. Furthermore, rather than using charge-coupled-device (CCD) to measure the pointer shift, we use the two-channel photoreceiver combined with lock-in amplifier (LIA) to measure the intensities of a split-Gaussian mode in this work. In this way, we introduce two intensity contrast ratios (ICRs) as special pointers to characterize the mean value and intensity shifts. As a result, the measurement precision of the polarization rotation is on the order of magnitude of 10−7rad\,10^{-7}rad10−7radin the experiment. These findings provide a distinctive insight into the weak measurement and have important implications for the accurate measurement of complex optical parameters.
Postselected weak measurement is a useful protocol for amplifying weak physical effects. However, there has recently been controversy over whether it gives any advantage in precision. While it is now clear that retaining failed postselections can yield more Fisher information than discarding them, the advantage of postselection measurement itself still remains to be clarified. In this Letter, we address this problem by studying two widely used estimation strategies: averaging measurement results, and maximum likelihood estimation, respectively. For the first strategy, we find a surprising result that squeezed coherent states of the pointer can give postselected weak measurements a higher signal-to-noise ratio than standard ones while all standard coherent states cannot, which suggests that raising the precision of weak measurements by postselection calls for the presence of "nonclassicality" in the pointer states. For the second strategy, we show that the quantum Fisher information of postselected weak measurements is generally larger than that of standard weak measurements, even without using the failed postselection events, but the gap can be closed with a proper choice of system state.
Abstract Weak measurements have many applications in the field of quantum information due to the peculiar properties of weak values. Quantum weak measurement can be performed by two particles or two degree of freedom of single particle. The former needs complex operations, the latter require the reconstruction of the motion state wavepacket, which consumes substantial quantum resources. This paper presents a novel weak measurement scheme that encodes multiple internal energy levels of a single particle into the measured system and the measuring pointer, while defining a finite-coupling postselected pointer ratio (FCPR). The FCPR obtained from this scheme enables both weak value amplification and rapid experimental results. To verify these advantages, we measured the FCPR using a trapped 40 Ca + experimental setup and monitored fluctuations of the laser power within the experimental system. The results show that our scheme can detect weaker laser power fluctuations, thus providing higher precision for laser power locking.
Background: Weak measurement involves weak coupling between the system and the measuring device (pointer) enables large amplification and high precision measurement of small physical parameters. The outcome of this special measurement procedure involving nearly mutually orthogonal pre- and post-selection of states in such weakly interacting systems leads to weak value that can become exceedingly large and lie outside the eigenvalue spectrum of the measured observable. This unprecedented ability of weak value amplification of small physical parameters has been successfully exploited for various metrological applications in the optical domain and beyond. Even though it is a quantum mechanical concept, it can be understood using the classical electromagnetic theory of light and thus can be realized in classical optics. Objective: Here, we briefly review the basic concepts of weak measurement and weak value amplification, provide illustrative examples of its implementation in various optical domains. The applications involve measuring ultra-sensitive beam deflections, high precision measurements of angular rotation, phase shift, temporal shift, frequency shift and so forth, and expand this extraordinary concept in the domain of nano-optics and plasmonics. Methods: In order to perform weak value amplification, we have used Gaussian beam and spectral response as the pointer subsequently. The polarization state associated with the pointer is used as pre and post-selection device. Results: We reveal the weak value amplification of sub-wavelength optical effects namely the Goos-Hänchen shift and the spin hall shift. Further, we demonstrate weak measurements using spectral line shape of resonance as a natural pointer, enabling weak value amplification beyond the conventional limit, demonstrating natural weak value amplification in plasmonic Fano resonances and so forth. The discussed concepts could have useful implications in various nano-optical systems to amplify tiny signals or effects. Conclusion: The emerging prospects of weak value amplification towards the development of novel optical weak measurement devices for metrological applications are extensively discussed.
The weak-value amplification is extensively considered in precision metrology in order to achieve a higher sensitivity. Despite the practical benefits in amplifying small physical quantities, its metrological advantage still arouses a broad debate due to the low postselection probability of success. In this paper, by employing the quantum Fisher information metric, we show that the precision of estimating an unknown parameter can be improved by introducing a precoupling process with properly chosen interaction operators. We point out this result is credible for both real and imaginary weak values. By tracking the meter wave functions, we find this enhancement of estimation precision comes from a precoupling induced modulation of the meter wave function, thus the most sensitive regime with respect to the parameter is reached. In addition, the estimation error is investigated by considering the difference between the theoretical and estimated value. The analysis suggests that this kind of error can be effectively suppressed by averaging the estimations resulted from different initial meter states. These results are finally illustrated by an exact numerical simulation where the advantages of our proposal are displayed by the comparison to the standard weak-value amplification scheme.