Optics Express

Nonlinear interferometric surface-plasmon-resonance sensor

Hailong Wang, Zhongxing Fu, Zhihao Ni, Xiong Zhang, Chunliu Zhao, Shangzhong Jin, Jietai Jing

Published Mar 13, 2021• 8 citations
Publisher

Abstract

A nonlinear interferometer can be constructed by replacing the beam splitter in the Mach-Zehnder interferometer with four-wave mixing (FWM) process. Meanwhile, the conventional surface plasmon resonance (SPR) sensors can be extensively used to infer the information of refractive index of the sample to be measured via either angle demodulation technique or intensity demodulation technique. Combined with a single FWM process, a quantum SPR sensor has been realized, whose noise floor is reduced below standard quantum limit with sensitivity unobtainable with classical SPR sensor. Therefore, in this work we have theoretically proposed a nonlinear interferometric SPR sensor, in which a conventional SPR sensor is placed inside nonlinear interferometer, which is called as I-type nonlinear interferometric SPR sensor. We demonstrate that near resonance angle I-type nonlinear interferometric SPR sensor has the following advantages: its degree of intensity-difference squeezing, estimation precision ratio, and signal-noise-ratio are improved by the factors of 4.6 dB, 2.3 dB, and 4.6 dB respectively than that obtained with a quantum SPR sensor based on a single FWM process. In addition, the theoretical principle of this work can also be expanded to other types of sensing, such as bending, pressure, and temperature sensors based on a nonlinear interferometer.

DOI
10.1364/oe.421217

Related papers

Quantum plasmonic sensing

Wenjiang Fan, Benjamin J. Lawrie, Raphael C. Pooser

Surface plasmon resonance (SPR) sensors can reach the quantum noise limit of the optical readout field in various configurations. We demonstrate that two-mode intensity squeezed states produce a further enhancement in sensitivity compared with a classical optical readout when the quantum noise is used to transduce an SPR sensor signal in the Kretschmann configuration. The quantum noise reduction between the twin beams when incident at an angle away from the plasmonic resonance, combined with quantum noise resulting from quantum anticorrelations when on resonance, results in an effective SPR-mediated modulation that yields a measured sensitivity 5 dB better than that with a classical optical readout in this configuration. The theoretical potential of this technique points to resolving particle concentrations with more accuracy than is possible via classical approaches to optical transduction.

Physical Review A•Nov 4, 2015•95 citations

Surface Plasmon Resonance (SPR) Sensor Based on Optimal Pre- and Post-Selection

Hailin Wang, Wenkang Li, Jianlin Huang +6 more

A surface plasmon resonance (SPR) refractive index sensing technique based on the optimal pre-and post-selection (PPS) is put forward. The intensity contrast ratio (ICR) is introduced to estimate the precision of this sensing technique. Compared with the traditional sensing techniques, our method shows that the ICR can be improved by about two orders of magnitude with optimal pre-and post-selected states. It is also proved that our sensing technique has a large tolerance for the metal film thickness and the incident angle. Remarkably, the method greatly reduces the cost of experiments, which is significant for promoting the widespread applications of SPR sensors.

IEEE photonics journal•Feb 4, 2019•6 citations

Quantum noise reduction in intensity-sensitive surface-plasmon-resonance sensors

Joong-Sung Lee, Trung Huynh, Su-Yong Lee +5 more

We investigate the use of twin-mode quantum states of light with symmetric statistical features in their photon number for improving intensity-sensitive surface plasmon resonance (SPR) sensors. For this purpose, one of the modes is sent into a prism setup where the Kretschmann configuration is employed as a sensing platform and the analyte to be measured influences the SPR excitation conditions. This influence modifies the output state of light that is subsequently analyzed by an intensity-difference measurement scheme. We show that quantum noise reduction is achieved not only as a result of the sub-Poissonian statistical nature of a single mode, but also as a result of the nonclassical correlation of the photon number between the two modes. When combined with the high sensitivity of the SPR sensor, we show that the use of twin-mode quantum states of light notably enhances the estimation precision of the refractive index of an analyte. With this we are able to identify a clear strategy to further boost the performance of SPR sensors, which are already a mature technology in biochemical and medical sensing applications.

arXiv:1705.05120•Physical Review A•Sep 19, 2017•39 citations

Phase sensitive measurements in a nonlinear interferometer using four-wave mixing in Rubidium-85

Tabitha Colter

Conventional interferometers make precision measurements by analyzing the position of interference fringes while nonlinear interferometers rely upon a sensitive measurement of phase difference. We detect this phase sensitivity using a correlated probe and conjugate beam that have undergone four-wave mixing inside a hot Rubidium-85 vapor cell. By placing a piece of glass into the path of the probe we observe a phase shift that indicates a successful nonlinear interferometer. We now plan to place into the probe path oils with known indices of refraction on plasmonic media and measure the resulting phase shifts. These results will then allow us to back-calculate an unknown material’s index of refraction simply by observing the phase shift with a level of sensitivity greater than conventional interferometers. Continued research in the field of interferometry utilizing nonlinear processes should provide even greater sensitivity in precision measurements and applications across a range of scientific disciplines.

•Jan 1, 2016•0 citations

Truncated Nonlinear Interferometry for Quantum-Enhanced Atomic Force Microscopy

Raphael C. Pooser, Nicholas J. Savino, Emma Batson +3 more

Nonlinear interferometers that replace beam splitters in Mach-Zehnder interferometers with nonlinear amplifiers for quantum-enhanced phase measurements have drawn increasing interest in recent years, but practical quantum sensors based on nonlinear interferometry remain an outstanding challenge. Here, we demonstrate the first practical application of nonlinear interferometry by measuring the displacement of an atomic force microscope microcantilever with quantum noise reduction of up to 3 dB below the standard quantum limit, corresponding to a quantum-enhanced measurement of beam displacement of 1.7 fm/sqrt[Hz]. Further, we minimize photon backaction noise while taking advantage of quantum noise reduction by transducing the cantilever displacement signal with a weak squeezed state while using dual homodyne detection with a higher power local oscillator. This approach may enable quantum-enhanced broadband, high-speed scanning probe microscopy.

arXiv:1912.10550•Physical Review Letters•Jun 12, 2020•61 citations

Quantum metrology with parametric amplifier-based photon correlation interferometers

Florian Hudelist, Jia Kong, Cunjin Liu +3 more

Conventional interferometers usually utilize beam splitters for wave splitting and recombination. These interferometers are widely used for precision measurement. Their sensitivity for phase measurement is limited by the shot noise, which can be suppressed with squeezed states of light. Here we study a new type of interferometer in which the beam splitting and recombination elements are parametric amplifiers. We observe an improvement of 4.1±0.3 dB in signal-to-noise ratio compared with a conventional interferometer under the same operating condition, which is a 1.6-fold enhancement in rms phase measurement sensitivity beyond the shot noise limit. The improvement is due to signal enhancement. Combined with the squeezed state technique for shot noise suppression, this interferometer promises further improvement in sensitivity. Furthermore, because nonlinear processes are involved in this interferometer, we can couple a variety of different waves and form new types of hybrid interferometers, opening a door for many applications in metrology. Interferometers play a key role in precision measurements and metrology. Here, the authors demonstrate a new type of interferometer that replaces the standard beam splitter elements with parametric amplifiers, which provides enhanced performance compared with a Mach–Zehnder interferometer.

Nature Communications•Jan 29, 2014•432 citations
A nonlinear interferometer can be constructed by replacing the beam splitter in the Mach-Zehnder interferometer with four-wave mixing (FWM) process. Meanwhile, the conventional surface plasmon resonance (SPR) sensors can be extensively used to infer the information of refractive index of the sample to be measured via either angle demodulation technique or intensity demodulation technique. Combined with a single FWM process, a quantum SPR sensor has been realized, whose noise floor is reduced below standard quantum limit with sensitivity unobtainable with classical SPR sensor. Therefore, in this work we have theoretically proposed a nonlinear interferometric SPR sensor, in which a conventional SPR sensor is placed inside nonlinear interferometer, which is called as I-type nonlinear interferometric SPR sensor. We demonstrate that near resonance angle I-type nonlinear interferometric SPR sensor has the following advantages: its degree of intensity-difference squeezing, estimation precision ratio, and signal-noise-ratio are improved by the factors of 4.6 dB, 2.3 dB, and 4.6 dB respectively than that obtained with a quantum SPR sensor based on a single FWM process. In addition, the theoretical principle of this work can also be expanded to other types of sensing, such as bending, pressure, and temperature sensors based on a nonlinear interferometer.
Surface plasmon resonance (SPR) sensors can reach the quantum noise limit of the optical readout field in various configurations. We demonstrate that two-mode intensity squeezed states produce a further enhancement in sensitivity compared with a classical optical readout when the quantum noise is used to transduce an SPR sensor signal in the Kretschmann configuration. The quantum noise reduction between the twin beams when incident at an angle away from the plasmonic resonance, combined with quantum noise resulting from quantum anticorrelations when on resonance, results in an effective SPR-mediated modulation that yields a measured sensitivity 5 dB better than that with a classical optical readout in this configuration. The theoretical potential of this technique points to resolving particle concentrations with more accuracy than is possible via classical approaches to optical transduction.
A surface plasmon resonance (SPR) refractive index sensing technique based on the optimal pre-and post-selection (PPS) is put forward. The intensity contrast ratio (ICR) is introduced to estimate the precision of this sensing technique. Compared with the traditional sensing techniques, our method shows that the ICR can be improved by about two orders of magnitude with optimal pre-and post-selected states. It is also proved that our sensing technique has a large tolerance for the metal film thickness and the incident angle. Remarkably, the method greatly reduces the cost of experiments, which is significant for promoting the widespread applications of SPR sensors.
We investigate the use of twin-mode quantum states of light with symmetric statistical features in their photon number for improving intensity-sensitive surface plasmon resonance (SPR) sensors. For this purpose, one of the modes is sent into a prism setup where the Kretschmann configuration is employed as a sensing platform and the analyte to be measured influences the SPR excitation conditions. This influence modifies the output state of light that is subsequently analyzed by an intensity-difference measurement scheme. We show that quantum noise reduction is achieved not only as a result of the sub-Poissonian statistical nature of a single mode, but also as a result of the nonclassical correlation of the photon number between the two modes. When combined with the high sensitivity of the SPR sensor, we show that the use of twin-mode quantum states of light notably enhances the estimation precision of the refractive index of an analyte. With this we are able to identify a clear strategy to further boost the performance of SPR sensors, which are already a mature technology in biochemical and medical sensing applications.
Conventional interferometers make precision measurements by analyzing the position of interference fringes while nonlinear interferometers rely upon a sensitive measurement of phase difference. We detect this phase sensitivity using a correlated probe and conjugate beam that have undergone four-wave mixing inside a hot Rubidium-85 vapor cell. By placing a piece of glass into the path of the probe we observe a phase shift that indicates a successful nonlinear interferometer. We now plan to place into the probe path oils with known indices of refraction on plasmonic media and measure the resulting phase shifts. These results will then allow us to back-calculate an unknown material’s index of refraction simply by observing the phase shift with a level of sensitivity greater than conventional interferometers. Continued research in the field of interferometry utilizing nonlinear processes should provide even greater sensitivity in precision measurements and applications across a range of scientific disciplines.
Nonlinear interferometers that replace beam splitters in Mach-Zehnder interferometers with nonlinear amplifiers for quantum-enhanced phase measurements have drawn increasing interest in recent years, but practical quantum sensors based on nonlinear interferometry remain an outstanding challenge. Here, we demonstrate the first practical application of nonlinear interferometry by measuring the displacement of an atomic force microscope microcantilever with quantum noise reduction of up to 3 dB below the standard quantum limit, corresponding to a quantum-enhanced measurement of beam displacement of 1.7 fm/sqrt[Hz]. Further, we minimize photon backaction noise while taking advantage of quantum noise reduction by transducing the cantilever displacement signal with a weak squeezed state while using dual homodyne detection with a higher power local oscillator. This approach may enable quantum-enhanced broadband, high-speed scanning probe microscopy.
Conventional interferometers usually utilize beam splitters for wave splitting and recombination. These interferometers are widely used for precision measurement. Their sensitivity for phase measurement is limited by the shot noise, which can be suppressed with squeezed states of light. Here we study a new type of interferometer in which the beam splitting and recombination elements are parametric amplifiers. We observe an improvement of 4.1±0.3 dB in signal-to-noise ratio compared with a conventional interferometer under the same operating condition, which is a 1.6-fold enhancement in rms phase measurement sensitivity beyond the shot noise limit. The improvement is due to signal enhancement. Combined with the squeezed state technique for shot noise suppression, this interferometer promises further improvement in sensitivity. Furthermore, because nonlinear processes are involved in this interferometer, we can couple a variety of different waves and form new types of hybrid interferometers, opening a door for many applications in metrology. Interferometers play a key role in precision measurements and metrology. Here, the authors demonstrate a new type of interferometer that replaces the standard beam splitter elements with parametric amplifiers, which provides enhanced performance compared with a Mach–Zehnder interferometer.