We report photoassociation spectroscopy of ultracold
86Sr atoms near the intercombination line and provide theoretical models to describe the obtained bound-state energies. We show that using only the molecular states correlating with the
1S0+3P1 asymptote is insufficient to provide a mass-scaled theoretical model that would reproduce the bound-state energies for all isotopes investigated to date:
84Sr,86Sr, and
88Sr. We attribute that to the recently discovered avoided crossing between the
1S0+3P1 0u+ $({}^{3}{\ensuremath{\Pi}}_{u})$ and
1S0+1D2 0u+ $({}^{1}{\ensuremath{\Sigma}}_{u}^{+})$ potential curves at short range and we build a mass-scaled interaction model that quantitatively reproduces the available
0u+ and
1u bound-state energies for the three stable bosonic isotopes. We also provide isotope-specific two-channel models that incorporate the rotational (Coriolis) mixing between the
0u+ and
1u curves which, while not mass scaled, are capable of quantitatively describing the vibrational splittings observed in experiment. We find that the use of state-of-the-art ab initio potential curves significantly improves the quantitative description of the Coriolis mixing between the two $\ensuremath{-}8$-GHz bound states in
88Sr over the previously used model potentials. We show that one of the recently reported energy levels in
84Sr does not follow the long-range bound-state series and theorize on the possible causes. Finally, we give the Coriolis-mixing angles and linear Zeeman coefficients for all of the photoassociation lines. The long-range van der Waals coefficients
C6(0u+)=3868(50) a.u. and
C6(1u)=4085(50) a.u. are reported.
The Coriolis effect can introduce significant systematic errors in atom interferometers. This study examines the coupling effect between the Coriolis effect and the Raman beams–orientation in a fountain atomic gravimeter. Theoretical analysis indicates that the Coriolis effect is correlated with the orientation of the Raman beams, and tilt modulation experiments were conducted to substantiate this correlation. Furthermore, by aligning the orientations of the atomic fountain, the vacuum chamber, and the Raman mirror, we achieved simultaneous suppression of both the Coriolis effect and the tilt effect to sub- μ Gal levels in a high-precision atomic gravimeter. This work offers guidance on assessing systematic errors in high-precision atomic gravimeters.
The alignment of Raman beams is important for high-precision atom interferometry gravimeters, and tilt modulation experiments are usually carried out to calibrate the direction of Raman beams. However, the Coriolis effect could be changed during the tilt modulation experiment, thus introducing a deviation in the alignment of Raman beams. In this work, a method of rotating the sensor head by 90° to eliminate the impact of the Coriolis effect on Raman beams' alignment in a fountain atom gravimeter was proposed and demonstrated experimentally. Using this method, the alignment uncertainty of the Raman beams in the atom gravimeter was reduced to 11 μrad, which contributed an uncertainty of less than 0.1 μGal (1 μGal = 1 × 10-8 m/s2) to the gravity measurement. Further simulations explained the experimental results and pointed out a way to reduce the Coriolis effect in atom gravimeters.