Proceedings of the ... annual Precise Time and Time Interval (PTTI) Systems and Applications Meeting/Proceedings of a meeting - Precise Time and Time Interval (PTTI) Systems and Applications Meeting

An Advanced-CSAC Testbed for Next-Generation Space Missions: Overview and Recent Results

Zachary Warren, Hunter Kettering, James C. Camparo

Published Feb 23, 2021• 0 citations
Publisher

Abstract

More and more, precise timekeeping is becoming a crucial element of space-system operations. Not only are atomic clocks required at mission control ground stations, but they are expected to fly on spacecraft ranging in size from the “large” to CubeSats. This, of course, requires that the size, weight, and power (SWaP) of the clock cannot be sacrificed for frequency stability, and that the frequency stability of the device cannot be sacrificed for SWaP. Traditional space clocks (e.g. Rb clocks, Cs clocks, and hydrogen masers) require microwave cavities, rf-discharge lamps, alkali ovens, hydrogen dissociators, filter vapor-cells, or state-selecting magnets. In contrast, Coherent-Population-Trapping (CPT) clocks can have very low SWaP and have led to the development of the chip-scale atomic-clock (CSAC) – perfect for CubeSat missions. In the standard CPT clock, a narrow atomic resonance is formed by a bichromatic optical field. Unfortunately, in the standard CPT clock design the atomic signal suffers a low signal-to-noise ratio (SNR), due to atoms becoming systemically stuck in “trap” states inaccessible to the laser light. At The Aerospace Corporation’s Physical Sciences Laboratories, we have constructed a CPT atomic clock testbed, with the goal of accelerating CSAC development for next-generation space missions. Specifically, our plan is to investigate atomic physics issues that influence CSAC performance and SWaP, and prioritizing issues not being addressed in academic or industrial laboratories. In this presentation, we will discuss our CPT testbed, and recent work investigating CPT-enhancement strategies for improved clock performance that recover atoms from trap states and improve the SNR. Additionally, we will discuss our studies of the physical processes taking place in these CPT-enhancement strategies, and how they can affect advanced-CSAC functioning and design.

DOI
10.33012/2021.17789

Related papers

A Versatile Testbed for CubeSat Atomic Clock Development: EOM vs Laser Current Modulation

Zachary Warren, Hunter Kettering, Pavel I. Ionov +2 more

Atomic clocks for compact satellite missions have limitations on size, weight, and power (SWaP), while requiring ever greater levels of frequency stability and accuracy. To aid in the development of next-generation low SWaP Coherent Population Trapping (CPT) clocks, we are developing a CubeSat Atomic Clock Testbed (CuSACT). This testbed will give us the capability to vary single aspects of CPT-clock design while keeping all others constant. In this presentation, we will provide an overview of CuSACT, and discuss our preliminary results comparing direct injection-current modulation of a VCSEL with electro-optic phase modulation of the VCSEL.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Apr 1, 2019•3 citations

Review of chip-scale atomic clocks based on coherent population trapping

Zhong Wang

Research on chip-scale atomic clocks (CSACs) based on coherent population trapping (CPT) is reviewed. The background and the inspiration for the research are described, including the important schemes proposed to improve the CPT signal quality, the selection of atoms and buffer gases, and the development of micro-cell fabrication. With regard to the reliability, stability, and service life of the CSACs, the research regarding the sensitivity of the CPT resonance to temperature and laser power changes is also reviewed, as well as the CPT resonance's collision and light of frequency shifts. The first generation CSACs have already been developed but its characters are still far from our expectations. Our conclusion is that miniaturization and power reduction are the most important aspects calling for further research.

Chinese Physics B•Mar 1, 2014•37 citations

A Versatile Testbed for CubeSat Atomic Clock Development: EOM vs Laser Current Modulation

Zachary Warren, Michael C. Y. Huang, Hunter Kettering +2 more

Atomic clock applications for CubeSat missions require low size, weight, and power (SWaP), while maintaining high stability and accuracy. This puts “large” microwave cavity clocks at a disadvantage, and encourages all-optical schemes of clock signal generation such as coherent population trapping (CPT). Two alternatives for optical pumping in compact atomic clocks are 1) electro-optic modulation (EOM) or 2) injection-current modulation (ICM) of the pump laser. CPT contrast and signal-to-noise ratio (SNR) are both influenced by the efficiency of sideband generation and suppression of the carrier frequency, which can vary between EOM and ICM methods. Light shift effects in CPT are also increased by asymmetry in the sideband intensities, a feature of ICM that can impair clock performance. The testbed we are developing enables reconfiguration of components in order to quantify compact-clock signal generation techniques and sensitivities, and their effects on CPT. This paper describes preliminary results from our testbed analysis of the EOM-based and ICM-based optical sideband generation schemes for compact CubeSat clocks.

Proceedings of the ... annual Precise Time and Time Interval (PTTI) Systems and Applications Meeting/Proceedings of a meeting - Precise Time and Time Interval (PTTI) Systems and Applications Meeting•Feb 23, 2018•2 citations

Polarization Modulated CPT and Population Distributions Among Ground-State Zeeman Sublevels

Zachary Warren, Hunter Kettering, Andrew Householder +1 more

SummaryChip-scale atomic clocks (CSAC) are the products of a burgeoning field of miniature precise timing efforts in support of low-SWaP space-qualified timing sources. Most CSACs are based on the coherent population trapping (CPT) effect, which uses laser light to selectively pump atoms into dark states. Because of the multiple accessible and inaccessible hyperfine Zeeman states, many atoms don’t contribute to the signal leading to a low signal-to-noise ratio of the CPT resonance. In turn, clock stability is limited. While solutions to this problem have been studied previously, the examination of the redistribution of atoms through the novel pumping solutions has not been thoroughly studied. This work provides continued exploration of an experimental effort to evaluate Zeeman end-state recovery schemes.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•May 15, 2023•0 citations

The Chip-Scale Atomic Clock - Recent Development Progress

Robert Lutwak, Donald A. Emmons, Thomas C. English +1 more

We have undertaken the development of a chip-scale atomic clock (CSAC) whose design goals include short-term stability, sigma(sub y)(tau=1 hour), of 1x10(exp 11) with a total power consumption of 30 mW and an overall device volume of 1 cu cm. The stringent power requirement dominates the physics package architecture, dictating a small (<5 mm(exp 3) gaseous atomic ensemble interrogated by a low-power semiconductor laser. At PTTI 2002, we reported on initial experimental investigations leading to the decision to employ the coherent population trapping (CPT) interrogation technique. This paper describes our further progress on the CSAC effort, including the development of custom vertical cavity surface emitting laser (VCSEL) sources and techniques for microfabricating miniature cesium vapor cells comprised of anodically bonded silicon and glass. Measurements of the signal contrast and linewidth of both the cesium D1 and D2 resonance transitions are compared, and frequency stability measurements of the CSAC testbed are presented.

•Sep 1, 2004•55 citations

VCSELs for atomic clocks

Darwin K. Serkland, Gregory M. Peake, K.M. Geib +4 more

The spectroscopic technique of coherent population trapping (CPT) enables an all-optical interrogation of the groundstate hyperfine splitting of cesium (or rubidium), compared to the optical-microwave double resonance technique conventionally employed in atomic frequency standards. All-optical interrogation enables the reduction of the size and power consumption of an atomic clock by two orders of magnitude, and vertical-cavity surface-emitting lasers (VCSELs) are preferred optical sources due to their low power consumption and circular output beam. Several research teams are currently using VCSELs for DARPA's chip-scale atomic clock (CSAC) program with the goal of producing an atomic clock having a volume < 1 cm^3, a power consumption < 30 mW, and an instability (Allan deviation) < 1x10^-11 during a 1-hour averaging interval. This paper describes the VCSEL requirements for CPT-based atomic clocks, which include single mode operation, single polarization operation, modulation bandwidth > 4 GHz, low power consumption (for the CSAC), narrow linewidth, and low relative intensity noise (RIN). A significant manufacturing challenge is to reproducibly obtain the required wavelength at the specified VCSEL operating temperature and drive current. Data are presented that show the advantage of operating at the D1 (rather than D2) resonance of the alkali atoms. Measurements of VCSEL linewidth will be discussed in particular, since atomic clock performance is especially sensitive to this parameter.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Feb 9, 2006•61 citations
More and more, precise timekeeping is becoming a crucial element of space-system operations. Not only are atomic clocks required at mission control ground stations, but they are expected to fly on spacecraft ranging in size from the “large” to CubeSats. This, of course, requires that the size, weight, and power (SWaP) of the clock cannot be sacrificed for frequency stability, and that the frequency stability of the device cannot be sacrificed for SWaP. Traditional space clocks (e.g. Rb clocks, Cs clocks, and hydrogen masers) require microwave cavities, rf-discharge lamps, alkali ovens, hydrogen dissociators, filter vapor-cells, or state-selecting magnets. In contrast, Coherent-Population-Trapping (CPT) clocks can have very low SWaP and have led to the development of the chip-scale atomic-clock (CSAC) – perfect for CubeSat missions. In the standard CPT clock, a narrow atomic resonance is formed by a bichromatic optical field. Unfortunately, in the standard CPT clock design the atomic signal suffers a low signal-to-noise ratio (SNR), due to atoms becoming systemically stuck in “trap” states inaccessible to the laser light. At The Aerospace Corporation’s Physical Sciences Laboratories, we have constructed a CPT atomic clock testbed, with the goal of accelerating CSAC development for next-generation space missions. Specifically, our plan is to investigate atomic physics issues that influence CSAC performance and SWaP, and prioritizing issues not being addressed in academic or industrial laboratories. In this presentation, we will discuss our CPT testbed, and recent work investigating CPT-enhancement strategies for improved clock performance that recover atoms from trap states and improve the SNR. Additionally, we will discuss our studies of the physical processes taking place in these CPT-enhancement strategies, and how they can affect advanced-CSAC functioning and design.
Atomic clocks for compact satellite missions have limitations on size, weight, and power (SWaP), while requiring ever greater levels of frequency stability and accuracy. To aid in the development of next-generation low SWaP Coherent Population Trapping (CPT) clocks, we are developing a CubeSat Atomic Clock Testbed (CuSACT). This testbed will give us the capability to vary single aspects of CPT-clock design while keeping all others constant. In this presentation, we will provide an overview of CuSACT, and discuss our preliminary results comparing direct injection-current modulation of a VCSEL with electro-optic phase modulation of the VCSEL.
Research on chip-scale atomic clocks (CSACs) based on coherent population trapping (CPT) is reviewed. The background and the inspiration for the research are described, including the important schemes proposed to improve the CPT signal quality, the selection of atoms and buffer gases, and the development of micro-cell fabrication. With regard to the reliability, stability, and service life of the CSACs, the research regarding the sensitivity of the CPT resonance to temperature and laser power changes is also reviewed, as well as the CPT resonance's collision and light of frequency shifts. The first generation CSACs have already been developed but its characters are still far from our expectations. Our conclusion is that miniaturization and power reduction are the most important aspects calling for further research.
Atomic clock applications for CubeSat missions require low size, weight, and power (SWaP), while maintaining high stability and accuracy. This puts “large” microwave cavity clocks at a disadvantage, and encourages all-optical schemes of clock signal generation such as coherent population trapping (CPT). Two alternatives for optical pumping in compact atomic clocks are 1) electro-optic modulation (EOM) or 2) injection-current modulation (ICM) of the pump laser. CPT contrast and signal-to-noise ratio (SNR) are both influenced by the efficiency of sideband generation and suppression of the carrier frequency, which can vary between EOM and ICM methods. Light shift effects in CPT are also increased by asymmetry in the sideband intensities, a feature of ICM that can impair clock performance. The testbed we are developing enables reconfiguration of components in order to quantify compact-clock signal generation techniques and sensitivities, and their effects on CPT. This paper describes preliminary results from our testbed analysis of the EOM-based and ICM-based optical sideband generation schemes for compact CubeSat clocks.
SummaryChip-scale atomic clocks (CSAC) are the products of a burgeoning field of miniature precise timing efforts in support of low-SWaP space-qualified timing sources. Most CSACs are based on the coherent population trapping (CPT) effect, which uses laser light to selectively pump atoms into dark states. Because of the multiple accessible and inaccessible hyperfine Zeeman states, many atoms don’t contribute to the signal leading to a low signal-to-noise ratio of the CPT resonance. In turn, clock stability is limited. While solutions to this problem have been studied previously, the examination of the redistribution of atoms through the novel pumping solutions has not been thoroughly studied. This work provides continued exploration of an experimental effort to evaluate Zeeman end-state recovery schemes.
We have undertaken the development of a chip-scale atomic clock (CSAC) whose design goals include short-term stability, sigma(sub y)(tau=1 hour), of 1x10(exp 11) with a total power consumption of 30 mW and an overall device volume of 1 cu cm. The stringent power requirement dominates the physics package architecture, dictating a small (<5 mm(exp 3) gaseous atomic ensemble interrogated by a low-power semiconductor laser. At PTTI 2002, we reported on initial experimental investigations leading to the decision to employ the coherent population trapping (CPT) interrogation technique. This paper describes our further progress on the CSAC effort, including the development of custom vertical cavity surface emitting laser (VCSEL) sources and techniques for microfabricating miniature cesium vapor cells comprised of anodically bonded silicon and glass. Measurements of the signal contrast and linewidth of both the cesium D1 and D2 resonance transitions are compared, and frequency stability measurements of the CSAC testbed are presented.
The spectroscopic technique of coherent population trapping (CPT) enables an all-optical interrogation of the groundstate hyperfine splitting of cesium (or rubidium), compared to the optical-microwave double resonance technique conventionally employed in atomic frequency standards. All-optical interrogation enables the reduction of the size and power consumption of an atomic clock by two orders of magnitude, and vertical-cavity surface-emitting lasers (VCSELs) are preferred optical sources due to their low power consumption and circular output beam. Several research teams are currently using VCSELs for DARPA's chip-scale atomic clock (CSAC) program with the goal of producing an atomic clock having a volume < 1 cm^3, a power consumption < 30 mW, and an instability (Allan deviation) < 1x10^-11 during a 1-hour averaging interval. This paper describes the VCSEL requirements for CPT-based atomic clocks, which include single mode operation, single polarization operation, modulation bandwidth > 4 GHz, low power consumption (for the CSAC), narrow linewidth, and low relative intensity noise (RIN). A significant manufacturing challenge is to reproducibly obtain the required wavelength at the specified VCSEL operating temperature and drive current. Data are presented that show the advantage of operating at the D1 (rather than D2) resonance of the alkali atoms. Measurements of VCSEL linewidth will be discussed in particular, since atomic clock performance is especially sensitive to this parameter.