Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Chinese Physics B

Super-sensitivity measurement of tiny Doppler frequency shifts based on parametric amplification and squeezed vacuum state

Zhiyuan Wang, Zijing Zhang, Yuan Zhe Zhao

Published Feb 7, 2021• 1 citation
Publisher

Abstract

The precision measurement of Doppler frequency shifts is of great significance for improving the precision of speed measurement. This paper proposes a precision measurement scheme of tiny Doppler shifts by a parametric amplification process and squeezed vacuum state. This scheme takes a parametric amplification process and squeezed vacuum state into a detection system, so that the measurement precision of tiny Doppler shifts can exceed the Cramér–Rao bound of coherent light. Simultaneously, a simulation study is carried out on the theoretical basis, and the following results are obtained: for the signal light of Gaussian mode, when the amplification factor g = 1 and the squeezed factor r = 0.5, the measurement error of Doppler frequency shifts is 14.4% of the Cramér–Rao bound of the coherent light in our system. At the same time, when the local light mode and squeezed vacuum state mode are optimized, the measurement precision of this scheme can be further improved by ( 2 n + 1 ) / ( n + 1 ) times, where n is the mode-order of the signal light.

DOI
10.1088/1674-1056/abe3e5

Related papers

Effect of phase-sensitive manipulations on generation of low-frequency two-mode orthogonal squeezed vacuum states

Wei Wu, Hao Ming Zhao, Jinxia Feng +3 more

Two-mode orthogonal squeezed vacuum states are an important quantum resource for quantum communication, quantum computing, quantum simulation, quantum precision measurement and sensing. It is essential to obtain stable two-mode orthogonal squeezed vacuum states in a low frequency range and compact configurations for practical applications, especially in quantum precision measurement and sensing. Two-mode orthogonal squeezed vacuum states are commonly produced via a subthreshold nondegenerate optical parametric amplifier (NOPA) in a continuous variable system. However, it is a difficult problem that the subthreshold NOPA cavity is phase sensitive manipulated to obtain stable squeezed vacuum states. Previous signal light injecting scheme relies on an injection of a weak light field into the subthreshold NOPA for phase sensitive manipulation. The injected signal light has the same frequency as the generated squeezed vacuum state. Thereby even the weakest injected signal light can introduce large amounts of excessive noise at low frequencies and the squeezing degree of two-mode squeezed vacuum states will be reduced or squeezing cannot be achieved. In this paper, a single sideband frequency shifted light injecting scheme is proposed for phase sensitive manipulation of NOPA. The comparison between the single sideband frequency shifted light injecting scheme and the signal light injecting scheme for realization of phase sensitive manipulation of NOPA is conducted. The effects of the two schemes on the generation of the low-frequency two-mode orthogonal squeezed vacuum state light field are investigated experimentally . The experimental results show that in the signal light injecting scheme for phase sensitive manipulation, the squeezing degree of the two-mode orthogonal squeezed vacuum state continuously decreases until it disappears as the power of injected signal light increases. In the process of phase sensitive manipulation of NOPA by using the single sideband frequency shifted light injecting scheme, the squeezing degree of the two-mode orthogonal squeezed vacuum state does not change with the power of the injected frequency shifted light increasing. Stable phase sensitive manipulation is realized by injecting single sideband frequency shifted light into NOPA. The NOPA is operated in a phase sensitive amplification state for 30 min. Stable low-frequency two-mode orthogonal squeezed vacuum states are obtained. The (4.1 ± 0.1) dB amplitude orthogonal squeezed vacuum states and (4.0 ± 0.2) dB phase orthogonal squeezed vacuum states at a frequency of 200 kHz are generated stably, in a compact NOPA configuration.

Acta Physica Sinica•Dec 12, 2023•0 citations

Phase locking of squeezed vacuum generated by a single-pass optical parametric amplifier

Yoshitaka Taguchi, Kenichi Oguchi, Zicong Xu +5 more

In high-precision optical measurements, squeezed vacuum states are a promising resource for reducing the shot noise. To utilize a squeezed vacuum, it is important to lock the phase of the local oscillator (LO) to the squeezed light. The coherent control sideband (CCSB) scheme has been established for the precise phase locking, while the previous CCSB scheme was designed for the squeezed vacuum generated with an optical parametric oscillator (OPO). Thus the previous CCSB scheme is not applicable to squeezing by a single-pass optical parametric amplifier (OPA), which is attractive for generating broadband squeezed vacuum states. In this study, we propose a variant of CCSB scheme, which is applicable to the squeezing by single-pass OPA. In this scheme, we inject pump light and frequency-shifted signal light into an OPA crystal in the same way as the previous CCSB scheme. The parametric process in the OPA crystal generates a squeezed vacuum, amplifies the signal light, generates an idler light, and causes the pump depletion reflecting the interference of the amplified signal light and the idler light. Through the lock-in detection of the pump depletion, we can phase-lock the injected signal light to the pump light. Then, after the heterodyne detection of the signal and the idler light, we get the error signal of LO and realize the precise phase locking of LO to the squeezed quadrature. We show the feasibility of the proposed scheme by deriving the signal-to-noise ratio (SNR) of the modulated pump signal. We experimentally demonstrate the proposed scheme on pulsed squeezing by a single-pass OPA.

Optics Express•Feb 11, 2022•14 citations

The phase sensitivity of an SU(1,1) interferometer with coherent and squeezed-vacuum light

Dong Li, Chun-Hua Yuan, Z. Y. Ou +1 more

We theoretically study the phase sensitivity of an SU(1,1) interferometer with a coherent state in one input port and a squeezed-vacuum state in the other input port using the method of homodyne detection. In this interferometer, beam splitting and recombination are generated by the parametric amplifiers instead of the beam splitters. Compared with the traditional Mach–Zehnder interferometer, the phase sensitivity of this interferometer can be improved due to the amplification process of the parametric amplifiers. Combined with the squeezed state input, the sensitivity can be improved further due to the noise reduction. The phase sensitivity of our scheme can approach the Heisenberg limit and the associated optimal condition is analyzed. The scheme can be implemented with current experimental technology.

arXiv:1305.4769•New Journal of Physics•Jul 17, 2014•122 citations

Quantum metrology of absorption and gain parameters using two-mode bright squeezed light

Mrunal Kamble, Jiaxuan Wang, G. S. Agarwal

Absorption and gain processes are fundamental to any light-matter interaction and a precise measurement of these parameters is important for various scientific and technological applications. Quantum probes, specifically the squeezed states, have proved very successful, particularly in the applications that deal with phase shift and force measurements. In this paper, we focus on improving the sensitivity of the estimation of the photon-loss coefficient of a weakly absorbing medium as well as the estimation of the gain parameter using a two-mode bright squeezed state. The generation of this state combines the advantage of a coherent beam for its large photon number with the quantum properties of the two-mode squeezing operation in an optical parametric amplifier. We present two measurement schemes: balanced photodetection and time-reversed metrology, both utilizing two-mode bright squeezed light. The maximum quantum advantage we can achieve using two-mode bright squeezed light is 3.7 times for the absorption parameter $\ensuremath{\alpha}=0.05$ and 8.4 times for $\ensuremath{\alpha}=0.01$ as compared to using only the coherent state. Similarly, the maximum quantum advantage for the estimation of optical gain is found around 2.95 times for the gain coefficient $G=1.05$ and around 6.35 times for $G=1.01$. We discuss the significance of using one measurement scheme over the other under different squeezing conditions. We compare our results with the Cram\'er-Rao bound for a two-mode bright squeezed state to assess the quality of the proposed methodologies.

arXiv:2404.00871•Physical Review A•May 16, 2024•17 citations

Bounds to precision for quantum interferometry with Gaussian states and operations

Carlo Sparaciari, Stefano Olivares, Matteo G. A. Paris

We address high-precision measurements by active and passive interferometric schemes based on Gaussian states and operations. In particular, we look for the best states to be injected into their ports according to the quantum Cramér–Rao bound, i.e., maximizing the quantum Fisher information over all the involved parameters, given a constraint on the overall mean number of photons entering into the interferometer. We found that for passive interferometers involving only beam splitters, the optimal input leading to Heisenberg scaling is a pair of identical squeezed-coherent states with at most one-third of the total energy employed in squeezing. For active interfer-ometers involving optical amplifiers, input coherent signals are enough to achieve Heisenberg scaling, given an optimal value of the amplification gain. For passive schemes our results clarify the role of squeezing in improving both the reference phase and the signal phase of an interferometer. © 2015 Optical Society of America OCIS codes: (270.6570) Squeezed states; (270.5570) Quantum detectors; (190.4970) Parametric oscillators and amplifiers; (120.3180) Interferometry.

Journal of the Optical Society of America B•Jun 5, 2015•63 citations

Simultaneous measurement of multimode squeezing through multimode phase-sensitive amplification

Ismail Barakat, Mahmoud Kalash, D. Scharwald +3 more

Multimode squeezed light is an increasingly popular tool in photonic quantum technologies, including sensing, imaging, and computation. Meanwhile, the existing methods of its characterization are technically complicated, which reduces the level of squeezing, and mostly deal with a single mode at a time. Here, for the first time, to the best of our knowledge, we employ optical parametric amplification to characterize multiple squeezing eigenmodes simultaneously. We retrieve the shapes and squeezing degrees of all modes at once through direct detection followed by modal decomposition. This method is tolerant to inefficient detection and does not require a local oscillator. For a spectrally and spatially multimode squeezed vacuum, we characterize eight strongest spatial modes, obtaining squeezing and anti-squeezing values of up to −5.2 ± 0.2 dB and 8.6 ± 0.3 dB, respectively, despite the 50% detection loss. This work, being the first exploration of an optical parametric amplifier’s multimode capability for squeezing detection, paves the way for the real-time detection of multimode squeezing.

arXiv:2402.15786•Optica Quantum•Dec 11, 2024•13 citations
The precision measurement of Doppler frequency shifts is of great significance for improving the precision of speed measurement. This paper proposes a precision measurement scheme of tiny Doppler shifts by a parametric amplification process and squeezed vacuum state. This scheme takes a parametric amplification process and squeezed vacuum state into a detection system, so that the measurement precision of tiny Doppler shifts can exceed the Cramér–Rao bound of coherent light. Simultaneously, a simulation study is carried out on the theoretical basis, and the following results are obtained: for the signal light of Gaussian mode, when the amplification factor g = 1 and the squeezed factor r = 0.5, the measurement error of Doppler frequency shifts is 14.4% of the Cramér–Rao bound of the coherent light in our system. At the same time, when the local light mode and squeezed vacuum state mode are optimized, the measurement precision of this scheme can be further improved by ( 2 n + 1 ) / ( n + 1 ) times, where n is the mode-order of the signal light.
Two-mode orthogonal squeezed vacuum states are an important quantum resource for quantum communication, quantum computing, quantum simulation, quantum precision measurement and sensing. It is essential to obtain stable two-mode orthogonal squeezed vacuum states in a low frequency range and compact configurations for practical applications, especially in quantum precision measurement and sensing. Two-mode orthogonal squeezed vacuum states are commonly produced via a subthreshold nondegenerate optical parametric amplifier (NOPA) in a continuous variable system. However, it is a difficult problem that the subthreshold NOPA cavity is phase sensitive manipulated to obtain stable squeezed vacuum states. Previous signal light injecting scheme relies on an injection of a weak light field into the subthreshold NOPA for phase sensitive manipulation. The injected signal light has the same frequency as the generated squeezed vacuum state. Thereby even the weakest injected signal light can introduce large amounts of excessive noise at low frequencies and the squeezing degree of two-mode squeezed vacuum states will be reduced or squeezing cannot be achieved. In this paper, a single sideband frequency shifted light injecting scheme is proposed for phase sensitive manipulation of NOPA. The comparison between the single sideband frequency shifted light injecting scheme and the signal light injecting scheme for realization of phase sensitive manipulation of NOPA is conducted. The effects of the two schemes on the generation of the low-frequency two-mode orthogonal squeezed vacuum state light field are investigated experimentally . The experimental results show that in the signal light injecting scheme for phase sensitive manipulation, the squeezing degree of the two-mode orthogonal squeezed vacuum state continuously decreases until it disappears as the power of injected signal light increases. In the process of phase sensitive manipulation of NOPA by using the single sideband frequency shifted light injecting scheme, the squeezing degree of the two-mode orthogonal squeezed vacuum state does not change with the power of the injected frequency shifted light increasing. Stable phase sensitive manipulation is realized by injecting single sideband frequency shifted light into NOPA. The NOPA is operated in a phase sensitive amplification state for 30 min. Stable low-frequency two-mode orthogonal squeezed vacuum states are obtained. The (4.1 ± 0.1) dB amplitude orthogonal squeezed vacuum states and (4.0 ± 0.2) dB phase orthogonal squeezed vacuum states at a frequency of 200 kHz are generated stably, in a compact NOPA configuration.
In high-precision optical measurements, squeezed vacuum states are a promising resource for reducing the shot noise. To utilize a squeezed vacuum, it is important to lock the phase of the local oscillator (LO) to the squeezed light. The coherent control sideband (CCSB) scheme has been established for the precise phase locking, while the previous CCSB scheme was designed for the squeezed vacuum generated with an optical parametric oscillator (OPO). Thus the previous CCSB scheme is not applicable to squeezing by a single-pass optical parametric amplifier (OPA), which is attractive for generating broadband squeezed vacuum states. In this study, we propose a variant of CCSB scheme, which is applicable to the squeezing by single-pass OPA. In this scheme, we inject pump light and frequency-shifted signal light into an OPA crystal in the same way as the previous CCSB scheme. The parametric process in the OPA crystal generates a squeezed vacuum, amplifies the signal light, generates an idler light, and causes the pump depletion reflecting the interference of the amplified signal light and the idler light. Through the lock-in detection of the pump depletion, we can phase-lock the injected signal light to the pump light. Then, after the heterodyne detection of the signal and the idler light, we get the error signal of LO and realize the precise phase locking of LO to the squeezed quadrature. We show the feasibility of the proposed scheme by deriving the signal-to-noise ratio (SNR) of the modulated pump signal. We experimentally demonstrate the proposed scheme on pulsed squeezing by a single-pass OPA.
We theoretically study the phase sensitivity of an SU(1,1) interferometer with a coherent state in one input port and a squeezed-vacuum state in the other input port using the method of homodyne detection. In this interferometer, beam splitting and recombination are generated by the parametric amplifiers instead of the beam splitters. Compared with the traditional Mach–Zehnder interferometer, the phase sensitivity of this interferometer can be improved due to the amplification process of the parametric amplifiers. Combined with the squeezed state input, the sensitivity can be improved further due to the noise reduction. The phase sensitivity of our scheme can approach the Heisenberg limit and the associated optimal condition is analyzed. The scheme can be implemented with current experimental technology.
Absorption and gain processes are fundamental to any light-matter interaction and a precise measurement of these parameters is important for various scientific and technological applications. Quantum probes, specifically the squeezed states, have proved very successful, particularly in the applications that deal with phase shift and force measurements. In this paper, we focus on improving the sensitivity of the estimation of the photon-loss coefficient of a weakly absorbing medium as well as the estimation of the gain parameter using a two-mode bright squeezed state. The generation of this state combines the advantage of a coherent beam for its large photon number with the quantum properties of the two-mode squeezing operation in an optical parametric amplifier. We present two measurement schemes: balanced photodetection and time-reversed metrology, both utilizing two-mode bright squeezed light. The maximum quantum advantage we can achieve using two-mode bright squeezed light is 3.7 times for the absorption parameter $\ensuremath{\alpha}=0.05$ and 8.4 times for $\ensuremath{\alpha}=0.01$ as compared to using only the coherent state. Similarly, the maximum quantum advantage for the estimation of optical gain is found around 2.95 times for the gain coefficient G=1.05G=1.05G=1.05 and around 6.35 times for G=1.01G=1.01G=1.01. We discuss the significance of using one measurement scheme over the other under different squeezing conditions. We compare our results with the Cram\'er-Rao bound for a two-mode bright squeezed state to assess the quality of the proposed methodologies.
We address high-precision measurements by active and passive interferometric schemes based on Gaussian states and operations. In particular, we look for the best states to be injected into their ports according to the quantum Cramér–Rao bound, i.e., maximizing the quantum Fisher information over all the involved parameters, given a constraint on the overall mean number of photons entering into the interferometer. We found that for passive interferometers involving only beam splitters, the optimal input leading to Heisenberg scaling is a pair of identical squeezed-coherent states with at most one-third of the total energy employed in squeezing. For active interfer-ometers involving optical amplifiers, input coherent signals are enough to achieve Heisenberg scaling, given an optimal value of the amplification gain. For passive schemes our results clarify the role of squeezing in improving both the reference phase and the signal phase of an interferometer. © 2015 Optical Society of America OCIS codes: (270.6570) Squeezed states; (270.5570) Quantum detectors; (190.4970) Parametric oscillators and amplifiers; (120.3180) Interferometry.
Multimode squeezed light is an increasingly popular tool in photonic quantum technologies, including sensing, imaging, and computation. Meanwhile, the existing methods of its characterization are technically complicated, which reduces the level of squeezing, and mostly deal with a single mode at a time. Here, for the first time, to the best of our knowledge, we employ optical parametric amplification to characterize multiple squeezing eigenmodes simultaneously. We retrieve the shapes and squeezing degrees of all modes at once through direct detection followed by modal decomposition. This method is tolerant to inefficient detection and does not require a local oscillator. For a spectrally and spatially multimode squeezed vacuum, we characterize eight strongest spatial modes, obtaining squeezing and anti-squeezing values of up to −5.2 ± 0.2 dB and 8.6 ± 0.3 dB, respectively, despite the 50% detection loss. This work, being the first exploration of an optical parametric amplifier’s multimode capability for squeezing detection, paves the way for the real-time detection of multimode squeezing.