International Conference on Optoelectronic and Microelectronic Technology and Application

Optical resonant measurement applied in magnetic field sensor

Qiang Huang, Bo Lang, Xiaofu He, Liang Bing, Xiaoliang Zhang, Lijie Song

Published Dec 4, 2020• 0 citations
Publisher

Abstract

Magnetic phenomenon is one of the earliest physical phenomena realized by human. The technology of high sensitivity magnetic field measurement has been used in many applications such as geophysical prospection, aerospace engineering, earth-magnetism navigation, biomedicine, fundamental physics, and so on. With the development of laser technology, the study of atomic magnetometer makes great progresses for the past few decades. This paper reports a magnetic field sensor with optical resonant measurement. Experiments have demonstrated the scalar component of the magnetic field with the resonant precession frequency of the coherent atoms and the vector component with the Lock-in Amplifier (LIA) phase shift on the field angle.

DOI
10.1117/12.2584503

Related papers

Vector measurements using all optical scalar atomic magnetometers

Rui Zhang, Rahul R. Mhaskar, Ken A. Smith +2 more

Vector field measurement is demonstrated with an all-optical scalar atomic magnetometer using intrinsic parameters related to its scalar operation. The Bell-Bloom type atomic magnetometer measures the Larmor precession of cesium atoms through on-resonant absorption of a probe beam. While the AC component of the probe signal is used for the field magnitude measurement, the probe DC signal contains information about the polar angle, defined as the angle between the magnetic field and the probe beam. Additional polar angle information is obtained from the light-shift-induced magnetic field caused by the frequency modulation of the probe beam. With a measurement time of 100 ms, better than 0.02° sensitivity has been achieved using a commercial miniaturized sensor at the optimal sensor orientation. The angle measurement accuracy is checked against an optical encoder over the entire polar angle range of 0°–180°. Better than 1° error is recorded over most set polar angles. Azimuthal angle measurement is also exhibited with two orthogonally oriented sensors.

arXiv:2011.08943•Journal of Applied Physics•Jan 28, 2021•17 citations

All-Optical Vector Atomic Magnetometer

Brian Patton, E. Zhivun, D. C. Hovde +1 more

We demonstrate an all-optical magnetometer capable of measuring the magnitude and direction of a magnetic field using nonlinear magneto-optical rotation in cesium vapor. Vector capability is added by effective modulation of the field along orthogonal axes and subsequent demodulation of the magnetic-resonance frequency. This modulation is provided by the ac Stark shift induced by circularly polarized laser beams. The sensor exhibits a demonstrated rms noise floor of $\ensuremath{\sim}65\text{ }\text{ }\mathrm{fT}/\sqrt{\mathrm{Hz}}$ in measurement of the field magnitude and $0.5\text{ }\text{ }\mathrm{mrad}/\sqrt{\mathrm{Hz}}$ in the field direction; elimination of technical noise would improve these sensitivities to $12\text{ }\text{ }\mathrm{fT}/\sqrt{\mathrm{Hz}}$ and $10\text{ }\text{ }\ensuremath{\mu}\mathrm{rad}/\sqrt{\mathrm{Hz}}$, respectively. Applications for this all-optical vector magnetometer would include magnetically sensitive fundamental physics experiments, such as the search for a permanent electric dipole moment of the neutron.

arXiv:1403.7545•Physical Review Letters•Jul 1, 2014•190 citations

Research on methods for weak signal detection of atomic magnetometers

Yang Liu, Wei Quan, Tao Wang

Atomic magnetometers use the coherent precession of polarized atomic spins to detect and measure magnetic fields. When an off-resonant, linearly polarized probe beam propagates through the atomic vapor cell, the precession will cause a rotation of its polarization plane. Measuring the angle of the rotation, the magnetic field can be calculated. In this paper, we introduce the basic principles of atomic magnetometers and describe the method to measure the angle. Then a dual-phase lock-in amplifier (LIA) is proposed to detect the weak signal of the atomic magnetometer. And we design a simulation for the LIA based on Matlab/Simulink. Our theoretical analysis and simulation results show that the detecting system is well working and it is possible to detect weak signal of magnetic fields in an accurate way.

Fifth International Symposium on Instrumentation and Control Technology•Jul 1, 2012•5 citations

All-optical vector atomic magnetometer

E. Zhivun, Brian Patton, Chris Hovde +1 more

We demonstrate an all-optical magnetometer capable of measuring the magnitude and direction of a magnetic field using nonlinear magneto-optical rotation in a cesium vapor. Vector capability is added by effective modulation of the field along orthogonal axes and subsequent demodulation of the magnetic-resonance frequency. This modulation is provided by the AC Stark shift induced by circularly polarized laser beams. The sensor exhibits a demonstrated rms noise floor of 50 fT/ √ Hz in measurement of the field magnitude and 0.5 mrad/ √ Hz in the field direction; elimination of technical noise would improve these sensitivities to 12 fT/ √ Hz and 5 μrad/ √ Hz, respectively. Applications for a precise all-optical vector magnetometer would include magnetically sensitive fundamental physics experiments, such as the search for a permanent electric dipole moment of the neutron.

Bulletin of the American Physical Society•Jun 5, 2014•24 citations

All-Optical Vector Cesium Magnetometer

Weimin Sun, Qiang Huang, Zongjun Huang +2 more

Based on power modulation of a pump laser and precessional projection detection, we present an all-optical vector magnetometer of cesium, which has a demonstrated magnitude sensitivity of 80 fT/Hz 1/2 and an orientation sensitivity of 0.1°/Hz 1/2 . In the device, four main factors are measured experimentally, which are the Larmor precession frequency of a polarized magnetic moment that depends on the modulus of the measured magnetic field only, two phase shifts and amplitude ratio of the precession projection in the two probe directions relative to the magnetic field orientation. This kind of magnetometer with high sensitivity in the range of the spatial angle is suitable for solving the inverse problem and geomagnetic navigation.

Chinese Physics Letters•May 1, 2017•12 citations

Shape of the Coherent Population Trapping Resonances Registered in Fluorescence

S. Gateva, G. Todorov

There has been permanent interest in investigations of new magnetic sensors and their various applications (Edelstein, 2007). Last years there is a rapid progress in development of magneto-optical sensors because of their sensitivity and potential for miniaturization. Magnetometers, based on magneto-optical sensors have high sensitivity comparable to, or even surpassing this of the SQUIDs (Superconducting Quantum Interference Devices) (Kominis et al., 2003; Dang et al., 2010; Savukov, 2010; Knappe, 2010). Microfabrication of components using the techniques of Micro-Electro-Mechanical Systems (MEMS) developed for atomic clocks (Knappe, 2004) gives the opportunity for building small, low consuming, low cost and non-cryogenic (as SQUIDs) sensors (Griffith et al., 2010). Coherent optical effects can be applied for magnetic field detection and offer perspectives for development of high-precision optical magnetometers (Cox et al., 2011; Kitching et al., 2011). These magnetometers are appropriate for geomagnetic, space, nuclear and biological magnetic field measurements (cardio and brain magnetic field imaging), environmental monitoring, magnetic microscopy, investigations of fundamental physics, etc. Coherent magneto-optical resonances have many applications not only in magnetometry, but in high-resolution spectroscopy, lasing without inversion, laser cooling, ultraslow group velocity propagation of light, etc. (Gao, 2009).

InTech eBooks•Mar 23, 2012•0 citations
Magnetic phenomenon is one of the earliest physical phenomena realized by human. The technology of high sensitivity magnetic field measurement has been used in many applications such as geophysical prospection, aerospace engineering, earth-magnetism navigation, biomedicine, fundamental physics, and so on. With the development of laser technology, the study of atomic magnetometer makes great progresses for the past few decades. This paper reports a magnetic field sensor with optical resonant measurement. Experiments have demonstrated the scalar component of the magnetic field with the resonant precession frequency of the coherent atoms and the vector component with the Lock-in Amplifier (LIA) phase shift on the field angle.
Vector field measurement is demonstrated with an all-optical scalar atomic magnetometer using intrinsic parameters related to its scalar operation. The Bell-Bloom type atomic magnetometer measures the Larmor precession of cesium atoms through on-resonant absorption of a probe beam. While the AC component of the probe signal is used for the field magnitude measurement, the probe DC signal contains information about the polar angle, defined as the angle between the magnetic field and the probe beam. Additional polar angle information is obtained from the light-shift-induced magnetic field caused by the frequency modulation of the probe beam. With a measurement time of 100 ms, better than 0.02° sensitivity has been achieved using a commercial miniaturized sensor at the optimal sensor orientation. The angle measurement accuracy is checked against an optical encoder over the entire polar angle range of 0°–180°. Better than 1° error is recorded over most set polar angles. Azimuthal angle measurement is also exhibited with two orthogonally oriented sensors.
We demonstrate an all-optical magnetometer capable of measuring the magnitude and direction of a magnetic field using nonlinear magneto-optical rotation in cesium vapor. Vector capability is added by effective modulation of the field along orthogonal axes and subsequent demodulation of the magnetic-resonance frequency. This modulation is provided by the ac Stark shift induced by circularly polarized laser beams. The sensor exhibits a demonstrated rms noise floor of $\ensuremath{\sim}65\text{ }\text{ }\mathrm{fT}/\sqrt{\mathrm{Hz}}$ in measurement of the field magnitude and 0.5  mrad/Hz0.5\text{ }\text{ }\mathrm{mrad}/\sqrt{\mathrm{Hz}}0.5  mrad/Hz​ in the field direction; elimination of technical noise would improve these sensitivities to 12  fT/Hz12\text{ }\text{ }\mathrm{fT}/\sqrt{\mathrm{Hz}}12  fT/Hz​ and $10\text{ }\text{ }\ensuremath{\mu}\mathrm{rad}/\sqrt{\mathrm{Hz}}$, respectively. Applications for this all-optical vector magnetometer would include magnetically sensitive fundamental physics experiments, such as the search for a permanent electric dipole moment of the neutron.
Atomic magnetometers use the coherent precession of polarized atomic spins to detect and measure magnetic fields. When an off-resonant, linearly polarized probe beam propagates through the atomic vapor cell, the precession will cause a rotation of its polarization plane. Measuring the angle of the rotation, the magnetic field can be calculated. In this paper, we introduce the basic principles of atomic magnetometers and describe the method to measure the angle. Then a dual-phase lock-in amplifier (LIA) is proposed to detect the weak signal of the atomic magnetometer. And we design a simulation for the LIA based on Matlab/Simulink. Our theoretical analysis and simulation results show that the detecting system is well working and it is possible to detect weak signal of magnetic fields in an accurate way.
We demonstrate an all-optical magnetometer capable of measuring the magnitude and direction of a magnetic field using nonlinear magneto-optical rotation in a cesium vapor. Vector capability is added by effective modulation of the field along orthogonal axes and subsequent demodulation of the magnetic-resonance frequency. This modulation is provided by the AC Stark shift induced by circularly polarized laser beams. The sensor exhibits a demonstrated rms noise floor of 50 fT/ √ Hz in measurement of the field magnitude and 0.5 mrad/ √ Hz in the field direction; elimination of technical noise would improve these sensitivities to 12 fT/ √ Hz and 5 μrad/ √ Hz, respectively. Applications for a precise all-optical vector magnetometer would include magnetically sensitive fundamental physics experiments, such as the search for a permanent electric dipole moment of the neutron.
Based on power modulation of a pump laser and precessional projection detection, we present an all-optical vector magnetometer of cesium, which has a demonstrated magnitude sensitivity of 80 fT/Hz 1/2 and an orientation sensitivity of 0.1°/Hz 1/2 . In the device, four main factors are measured experimentally, which are the Larmor precession frequency of a polarized magnetic moment that depends on the modulus of the measured magnetic field only, two phase shifts and amplitude ratio of the precession projection in the two probe directions relative to the magnetic field orientation. This kind of magnetometer with high sensitivity in the range of the spatial angle is suitable for solving the inverse problem and geomagnetic navigation.
There has been permanent interest in investigations of new magnetic sensors and their various applications (Edelstein, 2007). Last years there is a rapid progress in development of magneto-optical sensors because of their sensitivity and potential for miniaturization. Magnetometers, based on magneto-optical sensors have high sensitivity comparable to, or even surpassing this of the SQUIDs (Superconducting Quantum Interference Devices) (Kominis et al., 2003; Dang et al., 2010; Savukov, 2010; Knappe, 2010). Microfabrication of components using the techniques of Micro-Electro-Mechanical Systems (MEMS) developed for atomic clocks (Knappe, 2004) gives the opportunity for building small, low consuming, low cost and non-cryogenic (as SQUIDs) sensors (Griffith et al., 2010). Coherent optical effects can be applied for magnetic field detection and offer perspectives for development of high-precision optical magnetometers (Cox et al., 2011; Kitching et al., 2011). These magnetometers are appropriate for geomagnetic, space, nuclear and biological magnetic field measurements (cardio and brain magnetic field imaging), environmental monitoring, magnetic microscopy, investigations of fundamental physics, etc. Coherent magneto-optical resonances have many applications not only in magnetometry, but in high-resolution spectroscopy, lasing without inversion, laser cooling, ultraslow group velocity propagation of light, etc. (Gao, 2009).