Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Millimeter, Submillimeter, and Far-Infrared Detectors and Instrumentation for Astronomy XI

Millimeter-wave kinetic inductance detectors with no 1/f noise

Johannes Hubmayr, Jason E. Austermann, Bradley Dober, Gene C Hilton, Jiansong Gao, M. Malnou, Joel N. Ullom, Michael R. Vissers, Jordan Wheeler

Published Dec 12, 2020• 1 citation
Publisher

Abstract

We demonstrate microwave kinetic inductance detectors (MKIDs) whose sensitivity is limited by photon noise at 50 mHz signal frequencies. The sub-Hz part of the detection spectrum is important for millimeter-wave instruments, yet photon noise below 1 Hz in MKIDs has not previously been demonstrated unambiguously. Devices are feedhorn-coupled, direct-absorber-type and consist of lumped-element superconducting resonators fabricated from a hybrid of stoichiometric TiN, Al, and an amorphous-Si passivation layer. Viewing a 7K thermal load and a passband centered on 2mm, the device noise spectrum is white down to 50 mHz and has an amplitude consistent with photon noise. We will present these measurements and discuss the multiple design choices that lead to the result.

DOI
10.1117/12.2562870

Related papers

Ultrastable millimeter-wave kinetic inductance detectors

Michael R. Vissers, Jason E. Austermann, M. Malnou +6 more

We demonstrate microwave kinetic inductance detectors (MKIDs) whose sensitivity is limited by photon noise at signal frequencies as low as 50 mHz. The subhertz part of the detection spectrum is important for contemporary millimeter-wave science, yet photon noise below 1 Hz in MKIDs has not previously been unambiguously demonstrated. These feedhorn-coupled detectors are sensitive over a 40% fractional bandwidth centered on λ = 2 mm, are dual-polarization-sensitive, and consist of lumped-element superconducting resonators fabricated from a hybrid of stoichiometric TiN and Al films together with an amorphous-Si passivation layer. When observing a 7 K, 3.8 pW thermal load and employing no signal modulation scheme, the measured noise spectrum is white down to 50 mHz and has an amplitude consistent with photon noise. These results have implications for the development of large-format, polarization-sensitive, millimeter-wave imagers.

Applied Physics Letters•Jan 21, 2020•16 citations

Photon-noise limited sensitivity in titanium nitride kinetic inductance detectors

J. Hubmayr, J. Beall, D. Becker +14 more

We demonstrate photon-noise limited performance at sub-millimeter wavelengths in feedhorn-coupled, microwave kinetic inductance detectors made of a TiN/Ti/TiN trilayer superconducting film, tuned to have a transition temperature of 1.4 K. Micro-machining of the silicon-on-insulator wafer backside creates a quarter-wavelength backshort optimized for efficient coupling at 250 μm. Using frequency read out and when viewing a variable temperature blackbody source, we measure device noise consistent with photon noise when the incident optical power is >0.5 pW, corresponding to noise equivalent powers >3×10−17 W/Hz. This sensitivity makes these devices suitable for broadband photometric applications at these wavelengths.

arXiv:1406.4010•Applied Physics Letters•Feb 16, 2015•83 citations

Design methodology of hybrid-type microwave kinetic inductance detectors toward ground-based mm-submm observations

T. Tanaka, K. Karatsu, H.Kutsuma +16 more

Context. Microwave kinetic inductance detectors (MKIDs) are superconducting detectors that have the potential to contribute to the construction of over 10 000 pixel cameras required for mm and submm astronomical observations over the next decade. One of the issues related to its application is two-level-system (TLS) noise that creates a 1/ f term in the power spectrum density (PSD) of the detectors. A hybrid-type MKID has been proposed for TLS noise suppression without affecting the MKID performance. In this paper, we present a systematic method to model a hybrid-type MKID for mitigating TLS noise while achieving high sensitivity. Aims. Previous studies have shown that TLS noise in MKIDs depends on the sampling frequency, internal power, device geometry, and temperature. The strength of the electrical field distribution along the resonator line also affects the TLS noise properties. Based on this knowledge, we constructed a noise model of a hybrid-type MKID. Methods. Using this model, we designed MKIDs for the cosmic microwave background radiation experiment, GroundBIRD. We evaluated the 1/ f noise properties and NET of the fabricated devices using the on-site measurements. Based on the NET measurements, we can confirm that the white noise of fabricated detectors is limited by atmospheric photon noise. From the 1/ f noise measurements, we also confirm that it is possible to reach an atmospheric photon noise limit down to a low sampling frequency (i.e., of a few Hz) at the typical observation conditions from Teide observatory. Results. We confirm the design methodology we propose for hybrid-type MKID works well in optimizing the TLS model to the hybrid-type MKID, as evidenced by performance verification measurements carried out in the laboratory and on site.

Astronomy and Astrophysics•Aug 2, 2026•0 citations

Performance of hybrid NbTiN-Al microwave kinetic inductance detectors as direct detectors for sub-millimeter astronomy

R. M. J. Janssen, J. J. A. Baselmans, Akira Endo +4 more

In the next decades millimeter and sub-mm astronomy requires large format imaging arrays and broad-band spectrometers to complement the high spatial and spectral resolution of the Atacama Large Millimeter/submillimeter Array. The desired sensors for these instruments should have a background limited sensitivity and a high optical efficiency and enable arrays thousands of pixels in size. Hybrid microwave kinetic inductance detectors consisting of NbTiN and Al have shown to satisfy these requirements. We present the second generation hybrid NbTiN-Al MKIDs, which are photon noise limited in both phase and amplitude readout for loading levels P850GHz < 10 fW. Thanks to the increased responsivity, the photon noise level achieved in phase allows us to simultaneously read out approximately 8000 pixels using state-of-the-art electronics. In addition, the choice of superconducting materials and the use of a Si lens in combination with a planar antenna gives these resonators the flexibility to operate within the frequency range 0:09 < v < 1:1 THz. Given these specifications, hybrid NbTiN-Al MKIDs will enable astronomically usable kilopixel arrays for sub-mm imaging and moderate resolution spectroscopy.

arXiv:1408.3314•Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Jul 23, 2014•13 citations

Design and measurement of superconducting microwave kinetic inductance detectors

Florian Blauth

Microwave kinetic inductance detectors (MKID) are superconducting broadband direct detectors. If a superconducting thin film patterned into a resonator is illuminated with photons, Cooper pairs break up and the kinetic inductance of the film changes. This shifts the resonance frequency downwards and the dissipation of the resonator increases, which can be detected in the phase and amplitude of a transmitted signal. \n \nIn this thesis, a waveguide coupled MKID is designed and simulated. 350 GHz radiation is coupled into a copper waveguide via a horn antenna. A waveguide probe leads the signal onto a 9 µm silicon membrane where it is absorbed in a 40 nm superconducting aluminum film which is the inductive part of a superconducting resonator. The capacitor of the resonator is made of niobium. Two versions of the device are developed, a transmission line resonator and a lumped element resonator design. The new design will enable an accurate understanding of the optical sensitivity of MKIDs and allow comparison of different resonator materials. Since two different resonator types are used, the direct comparison of transmission line and lumped resonators will also be possible. \n \nA measurement setup is developed including an ADR cryostat to cool MKID devices down to below 40 mK. An analog readout system using either a vector network analyzer or an IQ mixer is designed and built. The necessary software to control the ADR, the temperature monitoring, the readout signal generation and detection and the signal acquisition of the setup is also developed. \n \nThe waveguide coupled MKID design is fabricated in our in-house microfabrication laboratory and measured in the new setup. In my measurements, the devices do not show a resonance feature. The VNA and DC measurements are analyzed to determine a plausible hypothesis of the failure. The devices are diagnosed for critical issues during fabrication which will be addressed in a future iteration. \n \nTo verify the measurement setup, a test device of the IRAM NIKA 2 MKID camera is measured and the complete analysis pipeline is exercised. The quasi-particle lifetime in the aluminum thin films is measured and a dark and optical noise equivalent power are determined. The results are within the uncertainty comparable to measurements of IRAM themselves. \n \nA test chip designed in my master thesis that contains eight NbTiN resonators is measured in the new setup and non-linear effects under strong readout power are studied. Parametric amplification and oscillation of a resonator are shown qualitatively.

•Oct 1, 2019•0 citations

Design and Readout of Large MKID Arrays for Submillimeter Astronomy

James A. Schlaerth, Omid Noroozian, Nicole G. Czakon +16 more

Microwave Kinetic Inductance Detectors (MKIDs) are superconducting microresonators useful as detectors for sub/millimeter and far-infrared cameras, as well as instruments in optical and x-ray wavelengths. A probe sine wave at the resonance frequency can detect a change in frequency and microwave loss due to submillimeter optical load as a phase or amplitude change. These detectors may be coupled to light through on-chip, phased-array antennas. A single antenna may feed several detectors with different bandpasses defined by on-chip lumped-element filters. The resonators are easily frequency multiplexed by tuning the resonance frequencies, so hundreds of detectors can be read out while coupled to a single feedline. The deployment and operation of ground-based, background-limited detectors in close-packed arrays present significant challenges in both readout strategy and array design. The initial designs consisted of simple coplanar waveguide microwave resonators with aluminum absorptive sections. The first change has been to substitute the capacitive portion of the resonator with a large interdigitated capacitor (IDC) to reduce its noise contribution. While their low-noise characteristics have been demonstrated, these detectors had not yet been tested on array-scale devices. We present results from arrays of detectors designed for sub/millimeter imaging, tested for their optical response characteristics. In particular, we address challenges of microwave inter-resonator coupling, out-of-band resonator optical sensitivity, and noise reduction in the latest device designs. We show the results of stepped-impedance filters in preventing direct pickup of wide-band radiation, and new frequency spacing to limit crosstalk between resonators. We show direct comparison between olderdesign coplanar waveguide resonators and new IDC resonators under optical load, demonstrating the noise reduction and comparable responsivity. In addition, we show results of the probe signal readout power that maximizes signal-to-noise.

Softwaretechnik-Trends•Mar 1, 2010•0 citations
We demonstrate microwave kinetic inductance detectors (MKIDs) whose sensitivity is limited by photon noise at 50 mHz signal frequencies. The sub-Hz part of the detection spectrum is important for millimeter-wave instruments, yet photon noise below 1 Hz in MKIDs has not previously been demonstrated unambiguously. Devices are feedhorn-coupled, direct-absorber-type and consist of lumped-element superconducting resonators fabricated from a hybrid of stoichiometric TiN, Al, and an amorphous-Si passivation layer. Viewing a 7K thermal load and a passband centered on 2mm, the device noise spectrum is white down to 50 mHz and has an amplitude consistent with photon noise. We will present these measurements and discuss the multiple design choices that lead to the result.
We demonstrate microwave kinetic inductance detectors (MKIDs) whose sensitivity is limited by photon noise at signal frequencies as low as 50 mHz. The subhertz part of the detection spectrum is important for contemporary millimeter-wave science, yet photon noise below 1 Hz in MKIDs has not previously been unambiguously demonstrated. These feedhorn-coupled detectors are sensitive over a 40% fractional bandwidth centered on λ = 2 mm, are dual-polarization-sensitive, and consist of lumped-element superconducting resonators fabricated from a hybrid of stoichiometric TiN and Al films together with an amorphous-Si passivation layer. When observing a 7 K, 3.8 pW thermal load and employing no signal modulation scheme, the measured noise spectrum is white down to 50 mHz and has an amplitude consistent with photon noise. These results have implications for the development of large-format, polarization-sensitive, millimeter-wave imagers.
We demonstrate photon-noise limited performance at sub-millimeter wavelengths in feedhorn-coupled, microwave kinetic inductance detectors made of a TiN/Ti/TiN trilayer superconducting film, tuned to have a transition temperature of 1.4 K. Micro-machining of the silicon-on-insulator wafer backside creates a quarter-wavelength backshort optimized for efficient coupling at 250 μm. Using frequency read out and when viewing a variable temperature blackbody source, we measure device noise consistent with photon noise when the incident optical power is >0.5 pW, corresponding to noise equivalent powers >3×10−17 W/Hz. This sensitivity makes these devices suitable for broadband photometric applications at these wavelengths.
Context. Microwave kinetic inductance detectors (MKIDs) are superconducting detectors that have the potential to contribute to the construction of over 10 000 pixel cameras required for mm and submm astronomical observations over the next decade. One of the issues related to its application is two-level-system (TLS) noise that creates a 1/ f term in the power spectrum density (PSD) of the detectors. A hybrid-type MKID has been proposed for TLS noise suppression without affecting the MKID performance. In this paper, we present a systematic method to model a hybrid-type MKID for mitigating TLS noise while achieving high sensitivity. Aims. Previous studies have shown that TLS noise in MKIDs depends on the sampling frequency, internal power, device geometry, and temperature. The strength of the electrical field distribution along the resonator line also affects the TLS noise properties. Based on this knowledge, we constructed a noise model of a hybrid-type MKID. Methods. Using this model, we designed MKIDs for the cosmic microwave background radiation experiment, GroundBIRD. We evaluated the 1/ f noise properties and NET of the fabricated devices using the on-site measurements. Based on the NET measurements, we can confirm that the white noise of fabricated detectors is limited by atmospheric photon noise. From the 1/ f noise measurements, we also confirm that it is possible to reach an atmospheric photon noise limit down to a low sampling frequency (i.e., of a few Hz) at the typical observation conditions from Teide observatory. Results. We confirm the design methodology we propose for hybrid-type MKID works well in optimizing the TLS model to the hybrid-type MKID, as evidenced by performance verification measurements carried out in the laboratory and on site.
In the next decades millimeter and sub-mm astronomy requires large format imaging arrays and broad-band spectrometers to complement the high spatial and spectral resolution of the Atacama Large Millimeter/submillimeter Array. The desired sensors for these instruments should have a background limited sensitivity and a high optical efficiency and enable arrays thousands of pixels in size. Hybrid microwave kinetic inductance detectors consisting of NbTiN and Al have shown to satisfy these requirements. We present the second generation hybrid NbTiN-Al MKIDs, which are photon noise limited in both phase and amplitude readout for loading levels P850GHz < 10 fW. Thanks to the increased responsivity, the photon noise level achieved in phase allows us to simultaneously read out approximately 8000 pixels using state-of-the-art electronics. In addition, the choice of superconducting materials and the use of a Si lens in combination with a planar antenna gives these resonators the flexibility to operate within the frequency range 0:09 < v < 1:1 THz. Given these specifications, hybrid NbTiN-Al MKIDs will enable astronomically usable kilopixel arrays for sub-mm imaging and moderate resolution spectroscopy.
Microwave kinetic inductance detectors (MKID) are superconducting broadband direct detectors. If a superconducting thin film patterned into a resonator is illuminated with photons, Cooper pairs break up and the kinetic inductance of the film changes. This shifts the resonance frequency downwards and the dissipation of the resonator increases, which can be detected in the phase and amplitude of a transmitted signal. \n \nIn this thesis, a waveguide coupled MKID is designed and simulated. 350 GHz radiation is coupled into a copper waveguide via a horn antenna. A waveguide probe leads the signal onto a 9 µm silicon membrane where it is absorbed in a 40 nm superconducting aluminum film which is the inductive part of a superconducting resonator. The capacitor of the resonator is made of niobium. Two versions of the device are developed, a transmission line resonator and a lumped element resonator design. The new design will enable an accurate understanding of the optical sensitivity of MKIDs and allow comparison of different resonator materials. Since two different resonator types are used, the direct comparison of transmission line and lumped resonators will also be possible. \n \nA measurement setup is developed including an ADR cryostat to cool MKID devices down to below 40 mK. An analog readout system using either a vector network analyzer or an IQ mixer is designed and built. The necessary software to control the ADR, the temperature monitoring, the readout signal generation and detection and the signal acquisition of the setup is also developed. \n \nThe waveguide coupled MKID design is fabricated in our in-house microfabrication laboratory and measured in the new setup. In my measurements, the devices do not show a resonance feature. The VNA and DC measurements are analyzed to determine a plausible hypothesis of the failure. The devices are diagnosed for critical issues during fabrication which will be addressed in a future iteration. \n \nTo verify the measurement setup, a test device of the IRAM NIKA 2 MKID camera is measured and the complete analysis pipeline is exercised. The quasi-particle lifetime in the aluminum thin films is measured and a dark and optical noise equivalent power are determined. The results are within the uncertainty comparable to measurements of IRAM themselves. \n \nA test chip designed in my master thesis that contains eight NbTiN resonators is measured in the new setup and non-linear effects under strong readout power are studied. Parametric amplification and oscillation of a resonator are shown qualitatively.
Microwave Kinetic Inductance Detectors (MKIDs) are superconducting microresonators useful as detectors for sub/millimeter and far-infrared cameras, as well as instruments in optical and x-ray wavelengths. A probe sine wave at the resonance frequency can detect a change in frequency and microwave loss due to submillimeter optical load as a phase or amplitude change. These detectors may be coupled to light through on-chip, phased-array antennas. A single antenna may feed several detectors with different bandpasses defined by on-chip lumped-element filters. The resonators are easily frequency multiplexed by tuning the resonance frequencies, so hundreds of detectors can be read out while coupled to a single feedline. The deployment and operation of ground-based, background-limited detectors in close-packed arrays present significant challenges in both readout strategy and array design. The initial designs consisted of simple coplanar waveguide microwave resonators with aluminum absorptive sections. The first change has been to substitute the capacitive portion of the resonator with a large interdigitated capacitor (IDC) to reduce its noise contribution. While their low-noise characteristics have been demonstrated, these detectors had not yet been tested on array-scale devices. We present results from arrays of detectors designed for sub/millimeter imaging, tested for their optical response characteristics. In particular, we address challenges of microwave inter-resonator coupling, out-of-band resonator optical sensitivity, and noise reduction in the latest device designs. We show the results of stepped-impedance filters in preventing direct pickup of wide-band radiation, and new frequency spacing to limit crosstalk between resonators. We show direct comparison between olderdesign coplanar waveguide resonators and new IDC resonators under optical load, demonstrating the noise reduction and comparable responsivity. In addition, we show results of the probe signal readout power that maximizes signal-to-noise.