Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

SPIE Optical and Infrared Interferometry and Imaging

On the quantum-limit of the noise temperature in balanced correlation receivers

Ernest A. Michael, M. Hadjara, Felipe E. Besser, Miguel I. Pina, D. Pollarolo, Antonio Rodriguez

Published Dec 11, 2020• 0 citations
Publisher

Abstract

Recent results for the cross-correlation signal of a newly proposed balanced correlation receiver at 1.5 μm pointed towards a possible bypassing of the standard quantum limit for the receiver noise-temperature hν⁄k in cross-correlation by a factor of 4-6. The only radiation source strong enough for a clear hot-cold measurement was a heavily attenuated fiber-coupled superluminant LED (SLED), because a multi-mode fiber-coupled thermal halogen lamp was difficult to control in polarization due to its weakness when coupled to a single-mode fiber. This peculiarity left some doubts regarding a possible “strange” quantum-mechanical behavior of the signal light from the SLED. Here we want to present the concept for more convincing measurements using a true thermal signal source.

DOI
10.1117/12.2563146

Related papers

On the Possibility of Breaking the Heterodyne Detection Quantum Noise Limit With Cross-Correlation

Ernest A. Michael, Felipe E. Besser

The cross-correlation sensitivity of two identical balanced photodiode heterodyne receivers is characterized. Both the balanced photodiodes receive the same weak signal split up equally, a situation equivalent to an astronomical spatial interferometer. A common local oscillator is also split up equally and its phase difference between both the receivers is stabilized. We show by a semi-classical photon deletion theory that the post-detection laser shot noise contributions on both the receivers must be completely uncorrelated in this case of passing three power splitters. We measured the auto- and cross-correlation outputs as a function of the weak signal power (system noise temperature measurement) and obtained a cross-correlation system noise temperature up to 20 times lower than for the auto-correlation system noise temperature of each receiver separately. This is supported by Allan plot measurements showing cross-correlation standard deviations 30 times lower than in auto-correlation. Careful calibration of the source power shows that the auto-correlation (regular) noise temperature of the single balanced receivers is already very near to the quantum limit as expected, which suggests a cross-correlation system noise temperature below the quantum limit. If validated further, this experimentally clear finding will not only be relevant for astronomical instrumentation but also for other fields, such as telecommunications and medical imaging.

arXiv:2101.05533•IEEE Access•Jan 1, 2018•7 citations

MMA Memo 161 Receiver Noise Temperature, the Quantum Noise Limit, and the Role of the Zero-Point Fluctuations *

Anthony R. Kerr, M. J. Feldman

There are in use at present three different ways of deducing the receiver noise temperature TR from the measured Y-factor, each resulting in a different value of TR. The methods differ in the way the physical of the hot and cold loads, Th and Tc (usually room temperature and liquid nitrogen), are converted into radiated power temperatures to deduce TR from Y. Only one of these methods is consistent with Tucker's quantum mixer theory and the constraints of Heisenberg's uncertainty principle. The paper also examines the minimum system noise achievable with single- and double-sideband receivers.

•Jan 1, 1997•1 citation

RECEIVER NOISE TEMPERATURE, THE QUANTUM NOISE LIMIT, AND THE ROLE OF THE ZERO-POINT FLUCTUATIONS

Anthony R. Kerr, M. J. Feldman

There are in use at present three different ways of deducing the receiver noise temperature TR from the measured Y-factor, each resulting in a different value of TR . The methods differ in the way the physical of the hot and cold loads, T h and Tc (usually room temperature and liquid nitrogen), are converted into radiated power temperatures to deduce T R from Y. Only one of these methods is consistent with Tucker's quantum mixer theory and the constraints of Heisenberg's uncertainty principle. The paper also examines the minimum system noise achievable with single- and double-sideband receivers.

Softwaretechnik-Trends•Jan 1, 1997•53 citations

A comparison between quantum and classical noise radar sources

Robert Jonsson, Roberto Di Candia, Martin Ankel +2 more

We compare the performance of a quantum radar based on two-mode squeezed states with a classical radar system based on correlated thermal noise. With a constraint of equal number of photons NStransmitted to probe the environment, we find that the quantum setup exhibits an advantage with respect to its classical counterpart of √2 in the cross-mode correlations. Amplification of the signal and the idler is considered at different stages of the protocol, showing that no quantum advantage is achievable when a large-enough gain is applied, even when quantum-limited amplifiers are available. We also characterize the minimal type-II error probability decay, given a constraint on the type-I error probability, and find that the optimal decay rate of the type-II error probability in the quantum setup is ln(1 + 1/NS) larger than the optimal classical setup, in the NS<; <; 1 regime. In addition, we consider the Receiver Operating Characteristic (ROC) curves for the scenario when the idler and the received signal are measured separately, showing that no quantum advantage is present in this case. Our work characterizes the trade-off between quantum correlations and noise in quantum radar systems.

arXiv:2008.12711•IEEE Radar Conference (RadarConf)•Sep 21, 2020•18 citations

A comparison between quantum and classical noise radar sources

Robert Jonsson, Roberto Di Candia, Martin Ankel +2 more

We compare the performance of a quantum radar based on two-mode squeezed states with a classical radar system based on correlated thermal noise. With a constraint of equal number of photons N-S transmitted to probe the environment, we find that the quantum setup exhibits an advantage with respect to its classical counterpart of root 2 in the cross-mode correlations. Amplification of the signal and the idler is considered at different stages of the protocol, showing that no quantum advantage is achievable when a large-enough gain is applied, even when quantum-limited amplifiers are available. We also characterize the minimal type-II error probability decay, given a constraint on the type-I error probability, and find that the optimal decay rate of the type-II error probability in the quantum setup is ln(1 + 1/N-S) larger than the optimal classical setup, in the N-S << 1 regime. In addition, we consider the Receiver Operating Characteristic (ROC) curves for the scenario when the idler and the received signal are measured separately, showing that no quantum advantage is present in this case. Our work characterizes the trade-off between quantum correlations and noise in quantum radar systems.

•Jan 1, 2020•20 citations

Quantum-Enhanced Strain and Temperature Sensing Based on Self-Imaging Principle in a Single-Multi-Single-Mode Fiber Structure

Dongxu Wang, Zihao Liu, Hailong Wang +3 more

To overcome the precision limitation imposed by classical common noise and standard quantum limit (SQL) in traditional classical sensing, a single-multi-single-mode (SMS) fiber optic sensor based on the combination of self-imaging principle and two-mode squeezed light source is proposed and experimentally demonstrated. The SMS sensor is constructed by fusing a multi-mode fiber in between two single-mode fiber segments. By utilizing an intensity-correlated twin beam source (signal and idler), the signal beam acts as the sensing probe interacting with the SMS sensor, while the idler beam serves as a reference to implement balanced differential measurement. The experimental results explicitly demonstrate a maximum signal-to-noise ratio enhancement of 1.196±0.012 dB and 1.194±0.019 dB for strain sensing (0 με to 2077.9 με) and temperature sensing (30°C to 110°C), respectively. These findings confirm the sensor's capability for real-time, high-precision sub-Poissonian measurements, particularly for practical applications in electromagnetic-immune and the requirements of simultaneous discrimination of temperature and strain.

IEEE Transactions on Instrumentation and Measurement•Jan 1, 2026•0 citations
Recent results for the cross-correlation signal of a newly proposed balanced correlation receiver at 1.5 μm pointed towards a possible bypassing of the standard quantum limit for the receiver noise-temperature hν⁄k in cross-correlation by a factor of 4-6. The only radiation source strong enough for a clear hot-cold measurement was a heavily attenuated fiber-coupled superluminant LED (SLED), because a multi-mode fiber-coupled thermal halogen lamp was difficult to control in polarization due to its weakness when coupled to a single-mode fiber. This peculiarity left some doubts regarding a possible “strange” quantum-mechanical behavior of the signal light from the SLED. Here we want to present the concept for more convincing measurements using a true thermal signal source.
The cross-correlation sensitivity of two identical balanced photodiode heterodyne receivers is characterized. Both the balanced photodiodes receive the same weak signal split up equally, a situation equivalent to an astronomical spatial interferometer. A common local oscillator is also split up equally and its phase difference between both the receivers is stabilized. We show by a semi-classical photon deletion theory that the post-detection laser shot noise contributions on both the receivers must be completely uncorrelated in this case of passing three power splitters. We measured the auto- and cross-correlation outputs as a function of the weak signal power (system noise temperature measurement) and obtained a cross-correlation system noise temperature up to 20 times lower than for the auto-correlation system noise temperature of each receiver separately. This is supported by Allan plot measurements showing cross-correlation standard deviations 30 times lower than in auto-correlation. Careful calibration of the source power shows that the auto-correlation (regular) noise temperature of the single balanced receivers is already very near to the quantum limit as expected, which suggests a cross-correlation system noise temperature below the quantum limit. If validated further, this experimentally clear finding will not only be relevant for astronomical instrumentation but also for other fields, such as telecommunications and medical imaging.
There are in use at present three different ways of deducing the receiver noise temperature TR from the measured Y-factor, each resulting in a different value of TR. The methods differ in the way the physical of the hot and cold loads, Th and Tc (usually room temperature and liquid nitrogen), are converted into radiated power temperatures to deduce TR from Y. Only one of these methods is consistent with Tucker's quantum mixer theory and the constraints of Heisenberg's uncertainty principle. The paper also examines the minimum system noise achievable with single- and double-sideband receivers.
There are in use at present three different ways of deducing the receiver noise temperature TR from the measured Y-factor, each resulting in a different value of TR . The methods differ in the way the physical of the hot and cold loads, T h and Tc (usually room temperature and liquid nitrogen), are converted into radiated power temperatures to deduce T R from Y. Only one of these methods is consistent with Tucker's quantum mixer theory and the constraints of Heisenberg's uncertainty principle. The paper also examines the minimum system noise achievable with single- and double-sideband receivers.
We compare the performance of a quantum radar based on two-mode squeezed states with a classical radar system based on correlated thermal noise. With a constraint of equal number of photons NStransmitted to probe the environment, we find that the quantum setup exhibits an advantage with respect to its classical counterpart of √2 in the cross-mode correlations. Amplification of the signal and the idler is considered at different stages of the protocol, showing that no quantum advantage is achievable when a large-enough gain is applied, even when quantum-limited amplifiers are available. We also characterize the minimal type-II error probability decay, given a constraint on the type-I error probability, and find that the optimal decay rate of the type-II error probability in the quantum setup is ln(1 + 1/NS) larger than the optimal classical setup, in the NS<; <; 1 regime. In addition, we consider the Receiver Operating Characteristic (ROC) curves for the scenario when the idler and the received signal are measured separately, showing that no quantum advantage is present in this case. Our work characterizes the trade-off between quantum correlations and noise in quantum radar systems.
We compare the performance of a quantum radar based on two-mode squeezed states with a classical radar system based on correlated thermal noise. With a constraint of equal number of photons N-S transmitted to probe the environment, we find that the quantum setup exhibits an advantage with respect to its classical counterpart of root 2 in the cross-mode correlations. Amplification of the signal and the idler is considered at different stages of the protocol, showing that no quantum advantage is achievable when a large-enough gain is applied, even when quantum-limited amplifiers are available. We also characterize the minimal type-II error probability decay, given a constraint on the type-I error probability, and find that the optimal decay rate of the type-II error probability in the quantum setup is ln(1 + 1/N-S) larger than the optimal classical setup, in the N-S << 1 regime. In addition, we consider the Receiver Operating Characteristic (ROC) curves for the scenario when the idler and the received signal are measured separately, showing that no quantum advantage is present in this case. Our work characterizes the trade-off between quantum correlations and noise in quantum radar systems.
To overcome the precision limitation imposed by classical common noise and standard quantum limit (SQL) in traditional classical sensing, a single-multi-single-mode (SMS) fiber optic sensor based on the combination of self-imaging principle and two-mode squeezed light source is proposed and experimentally demonstrated. The SMS sensor is constructed by fusing a multi-mode fiber in between two single-mode fiber segments. By utilizing an intensity-correlated twin beam source (signal and idler), the signal beam acts as the sensing probe interacting with the SMS sensor, while the idler beam serves as a reference to implement balanced differential measurement. The experimental results explicitly demonstrate a maximum signal-to-noise ratio enhancement of 1.196±0.012 dB and 1.194±0.019 dB for strain sensing (0 με to 2077.9 με) and temperature sensing (30°C to 110°C), respectively. These findings confirm the sensor's capability for real-time, high-precision sub-Poissonian measurements, particularly for practical applications in electromagnetic-immune and the requirements of simultaneous discrimination of temperature and strain.