Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Acta Physica Sinica

Differential compressive correlated imaging

Bai Xu, Yongqiang Li, Shengmei Zhao

Published Jan 1, 2013• 16 citations
Publisher

Abstract

Correlated imaging offers great potentiality, with respect to standard imaging, to obtain the imaging of objects located in optically harsh or noisy environment. It can solve the problems which are difficult to solve by conventional imaging techniques. Recently, it has become one of the hot topics in quantum optics. In this paper, we propose a new scheme of correlated imaging with differential correlated imaging based on compressive sensing, named differential compressive correlated imaging. The new scheme takes advantage of the high signal-to-noise ratio of the differential correlated imaging and low-imaging sampling frequency of the compressed sensing technique. In the scheme, we utilize the intensity of the thermal light, which is in line with the Gaussian distribution, as the measurement matrix of compressive sensing. We extract the differential object information as the image object information which could be recovered via orthogonal matching pursuit algorithm with high quality. By numerical simulations, we verify the proposed scheme. Here, we select the two gray-scale images, such as double-slit and NUPT, as well as the two multi-grayscale images (Lena and Boats) as the object. We take sampling 350 times in differential compressive correlated imaging for measurement. The numerical simulation results show that for the above image objects, the average mean-square error (MSE) over 10 times for the differential compressive correlated imaging scheme is reduced by 97.7%, 93.9%, 92.5% and 71.4% respectively with respect to that of the differential correlated imaging scheme. Moreover, compared with the compressive ghost imaging, the MSE value of the same double-slit in CDGI, as well as Lena and Boats under the same conditions, is reduced by 50.4%, 72.9% and 66.8% separately, which indicates that the compressive differential correlated imaging scheme can greatly improve the signal-to-noise ratio of the imaging, and significantly reduce the imaging time.

DOI
10.7498/aps.62.044209

Related papers

Robust Entangled-Photon Ghost Imaging with Compressive Sensing

Jun Li, Wenyu Gao, Jiachuan Qian +3 more

This work experimentally demonstrates that the imaging quality of quantum ghost imaging (GI) with entangled photons can be significantly improved by properly handling the errors caused by the imperfection of optical devices. We also consider compressive GI to reduce the number of measurements and thereby the data acquisition time. The image reconstruction is formulated as a sparse total least square problem which is solved with an iterative algorithm. Our experiments show that, compared with existing methods, the new method can achieve a significant performance gain in terms of mean square error and peak signal⁻noise ratio.

Sensors•Jan 7, 2019•16 citations

Quantum differential ghost microscopy

Elena Losero, Ivano Ruo Berchera, Alice Meda +3 more

Quantum correlations become formidable tools for beating classical capacities of measurement. Preserving these advantages in practical systems, where experimental imperfections are unavoidable, is a challenge of the utmost importance. Here we propose and realize a quantum ghost imaging protocol stemming from the differential ghost imaging, a scheme elaborated so far in the limit of bright thermal light, particularly suitable in the relevant case of faint or sparse objects. The extension toward the quantum regime represents an important step as quantum correlations allow low-brightness imaging, desirable for reducing the absorption dose. Furthermore, we optimize the protocol in terms of signal-to-noise ratio, to compensate for the detrimental effects of detection noise and losses. We perform the experiment using spontaneous parametric down conversion light in a microscope configuration. The image is reconstructed exploiting nonclassical intensity correlation in the low photon flux regime, rather than photon pairs detection coincidences. On the one side, we validate the theoretical model and on the other we show the applicability of this technique by imaging biological samples.

arXiv:1903.12630•Physical Review A•Dec 10, 2019•23 citations

Sampling number of image reconstruction arithmetic based on quantum correlated imaging

SU Fen

Quantum correlated imaging technology adopts single-point intensity detecting,huge information storage,slow imaging speed,so faster image reconstruction algorithm was required.The simulation of samples with image reconstructing algorithm was based on statistical arithmetic and compressed sensing respectively.The inputs of the compressed sensing algorithm are sparse images which are calculated with discrete cosine transform(DCT) and Gauss random matrices,reconstructing image with orthogonal matching pursuit(OMP).The result shows that the correlated imaging algorithm based on compressed sensing can lessen the number of measurements and save data space and speed.Therefore,the study of quantum correlated imaging image reconstruction algorithm has great significance for lessening the number of samples and improving imaging speed.

Chinese Journal of Quantum Electronics•Jan 1, 2015•0 citations

Compressive Sensing for Quantum Imaging

Gregory A. Howland

This thesis describes the application of compressive sensing to several challenging problems in quantum imaging with practical and fundamental implications. Compressive sensing is a measurement technique that compresses a signal during measurement such that it can be dramatically undersampled. Compressive sensing has been shown to be an extremely efficient measurement technique for imaging, particularly when detector arrays are not available. The thesis first reviews compressive sensing through the lens of quantum imaging and quantum measurement. Four important applications and their corresponding experiments are then described in detail. The first application is a compressive sensing, photon-counting lidar system. A novel depth mapping technique that uses standard, linear compressive sensing is described. Depth maps up to 256 x 256 pixel transverse resolution are recovered with depth resolution less than 2.54 cm. The first three-dimensional, photon counting video is recorded at 32 x 32 pixel resolution and 14 frames-per-second. The second application is the use of compressive sensing for complementary imaging--simultaneously imaging the transverse-position and transverse-momentum distributions of optical photons. This is accomplished by taking random, partial projections of position followed by imaging the momentum distribution on a cooled CCD camera. The projections are shown to not signicantly perturb the photons' momenta while allowing high resolution position images to be reconstructed using compressive sensing. A variety of objects and their diffraction patterns are imaged including the double slit, triple slit, alphanumeric characters, and the University of Rochester logo. The third application is the use of compressive sensing to characterize spatial entanglement of photon pairs produced by spontaneous parametric downconversion. The technique gives a theoretical speedup N2/log N for N-dimensional entanglement over the standard raster scanning technique. Entanglement imaging is demonstrated at 1024 dimensions-per-photon with channel capacities exceeding 8.4 bits-per-photon. In practice, the measurement time is reduced from 310 days for the standard technique to 8 hours for the compressive technique. An entropic steering inequality is violated to witness entanglement. The final application is a compressive wavefront sensor that unites compressive sensing with weak measurement. We show how a twisted-nematic spatial light modulator can be be used to weakly couple an optical field's position and polarization degrees of freedom. The complex nature of the weak value is used to directly measure random projections of the real and imaginary parts of the optical field, where polarization serves as an ancillary meter. We obtain 256 x 256 pixel wavefronts from only 10,000 random projections. Photon-counting detectors provide sub-picowatt sensitivity.

•Jan 1, 2014•4 citations

Complementary Normalized Compressive Ghost Imaging With Entangled Photons

Dawei Liu, Lifei Li, Hui Chen +5 more

We demonstrate a compressive normalized ghost imaging system with entangled photons employing complementary compressive imaging (CCI) technique. The quantum ghost image reconstruction was achieved with 19.53% sampling ratio of raster scanning and average 0.78 photons/pixel of each measurement. Using the special +1/-1 type sensing matrix and appropriate optimal algorithm, the photon utilization efficiency, and robustness of the imaging system is enhanced significantly. Our results reveal the great potential of CCI technique applied in quantum imaging and other quantum optics field such as quantum characterizing and quantum state tomography to use the information loaded in each photon with high efficiency.

arXiv:1703.04348•IEEE photonics journal•Mar 12, 2018•6 citations

Entangled-photons compressive ghost imaging based on spatial correlation of sensing matrix

Dawei Liu, Lifei Li, Yixing Geng +5 more

Using the entangled photons generated by the spontaneous parametric down conversion as a light source, we demonstrate the first quantum ghost imaging system with a modified compressive sensing technique based on the spatial correlation of sensing matrix (SCCS). The ghost image is achieved at 16.27% sampling ratio of raster scanning and 0.65 photons/pixel at each measurement on average. Our results show that image quality and photon-utilization efficiency are remarkably enhanced in comparison with the traditional compressive imaging technique, due to the sensing matrix and noise-free measurement vector rebuilt by SCCS technique. It suggests the great potential of SCCS technique applied in quantum imaging and other quantum optics fields, such as quantum charactering and quantum state tomography to use the information loaded in each photon with high efficiency.

Optical Engineering•Dec 23, 2017•5 citations
Correlated imaging offers great potentiality, with respect to standard imaging, to obtain the imaging of objects located in optically harsh or noisy environment. It can solve the problems which are difficult to solve by conventional imaging techniques. Recently, it has become one of the hot topics in quantum optics. In this paper, we propose a new scheme of correlated imaging with differential correlated imaging based on compressive sensing, named differential compressive correlated imaging. The new scheme takes advantage of the high signal-to-noise ratio of the differential correlated imaging and low-imaging sampling frequency of the compressed sensing technique. In the scheme, we utilize the intensity of the thermal light, which is in line with the Gaussian distribution, as the measurement matrix of compressive sensing. We extract the differential object information as the image object information which could be recovered via orthogonal matching pursuit algorithm with high quality. By numerical simulations, we verify the proposed scheme. Here, we select the two gray-scale images, such as double-slit and NUPT, as well as the two multi-grayscale images (Lena and Boats) as the object. We take sampling 350 times in differential compressive correlated imaging for measurement. The numerical simulation results show that for the above image objects, the average mean-square error (MSE) over 10 times for the differential compressive correlated imaging scheme is reduced by 97.7%, 93.9%, 92.5% and 71.4% respectively with respect to that of the differential correlated imaging scheme. Moreover, compared with the compressive ghost imaging, the MSE value of the same double-slit in CDGI, as well as Lena and Boats under the same conditions, is reduced by 50.4%, 72.9% and 66.8% separately, which indicates that the compressive differential correlated imaging scheme can greatly improve the signal-to-noise ratio of the imaging, and significantly reduce the imaging time.
This work experimentally demonstrates that the imaging quality of quantum ghost imaging (GI) with entangled photons can be significantly improved by properly handling the errors caused by the imperfection of optical devices. We also consider compressive GI to reduce the number of measurements and thereby the data acquisition time. The image reconstruction is formulated as a sparse total least square problem which is solved with an iterative algorithm. Our experiments show that, compared with existing methods, the new method can achieve a significant performance gain in terms of mean square error and peak signal⁻noise ratio.
Quantum correlations become formidable tools for beating classical capacities of measurement. Preserving these advantages in practical systems, where experimental imperfections are unavoidable, is a challenge of the utmost importance. Here we propose and realize a quantum ghost imaging protocol stemming from the differential ghost imaging, a scheme elaborated so far in the limit of bright thermal light, particularly suitable in the relevant case of faint or sparse objects. The extension toward the quantum regime represents an important step as quantum correlations allow low-brightness imaging, desirable for reducing the absorption dose. Furthermore, we optimize the protocol in terms of signal-to-noise ratio, to compensate for the detrimental effects of detection noise and losses. We perform the experiment using spontaneous parametric down conversion light in a microscope configuration. The image is reconstructed exploiting nonclassical intensity correlation in the low photon flux regime, rather than photon pairs detection coincidences. On the one side, we validate the theoretical model and on the other we show the applicability of this technique by imaging biological samples.
Quantum correlated imaging technology adopts single-point intensity detecting,huge information storage,slow imaging speed,so faster image reconstruction algorithm was required.The simulation of samples with image reconstructing algorithm was based on statistical arithmetic and compressed sensing respectively.The inputs of the compressed sensing algorithm are sparse images which are calculated with discrete cosine transform(DCT) and Gauss random matrices,reconstructing image with orthogonal matching pursuit(OMP).The result shows that the correlated imaging algorithm based on compressed sensing can lessen the number of measurements and save data space and speed.Therefore,the study of quantum correlated imaging image reconstruction algorithm has great significance for lessening the number of samples and improving imaging speed.
This thesis describes the application of compressive sensing to several challenging problems in quantum imaging with practical and fundamental implications. Compressive sensing is a measurement technique that compresses a signal during measurement such that it can be dramatically undersampled. Compressive sensing has been shown to be an extremely efficient measurement technique for imaging, particularly when detector arrays are not available. The thesis first reviews compressive sensing through the lens of quantum imaging and quantum measurement. Four important applications and their corresponding experiments are then described in detail. The first application is a compressive sensing, photon-counting lidar system. A novel depth mapping technique that uses standard, linear compressive sensing is described. Depth maps up to 256 x 256 pixel transverse resolution are recovered with depth resolution less than 2.54 cm. The first three-dimensional, photon counting video is recorded at 32 x 32 pixel resolution and 14 frames-per-second. The second application is the use of compressive sensing for complementary imaging--simultaneously imaging the transverse-position and transverse-momentum distributions of optical photons. This is accomplished by taking random, partial projections of position followed by imaging the momentum distribution on a cooled CCD camera. The projections are shown to not signicantly perturb the photons' momenta while allowing high resolution position images to be reconstructed using compressive sensing. A variety of objects and their diffraction patterns are imaged including the double slit, triple slit, alphanumeric characters, and the University of Rochester logo. The third application is the use of compressive sensing to characterize spatial entanglement of photon pairs produced by spontaneous parametric downconversion. The technique gives a theoretical speedup N2/log N for N-dimensional entanglement over the standard raster scanning technique. Entanglement imaging is demonstrated at 1024 dimensions-per-photon with channel capacities exceeding 8.4 bits-per-photon. In practice, the measurement time is reduced from 310 days for the standard technique to 8 hours for the compressive technique. An entropic steering inequality is violated to witness entanglement. The final application is a compressive wavefront sensor that unites compressive sensing with weak measurement. We show how a twisted-nematic spatial light modulator can be be used to weakly couple an optical field's position and polarization degrees of freedom. The complex nature of the weak value is used to directly measure random projections of the real and imaginary parts of the optical field, where polarization serves as an ancillary meter. We obtain 256 x 256 pixel wavefronts from only 10,000 random projections. Photon-counting detectors provide sub-picowatt sensitivity.
We demonstrate a compressive normalized ghost imaging system with entangled photons employing complementary compressive imaging (CCI) technique. The quantum ghost image reconstruction was achieved with 19.53% sampling ratio of raster scanning and average 0.78 photons/pixel of each measurement. Using the special +1/-1 type sensing matrix and appropriate optimal algorithm, the photon utilization efficiency, and robustness of the imaging system is enhanced significantly. Our results reveal the great potential of CCI technique applied in quantum imaging and other quantum optics field such as quantum characterizing and quantum state tomography to use the information loaded in each photon with high efficiency.
Using the entangled photons generated by the spontaneous parametric down conversion as a light source, we demonstrate the first quantum ghost imaging system with a modified compressive sensing technique based on the spatial correlation of sensing matrix (SCCS). The ghost image is achieved at 16.27% sampling ratio of raster scanning and 0.65 photons/pixel at each measurement on average. Our results show that image quality and photon-utilization efficiency are remarkably enhanced in comparison with the traditional compressive imaging technique, due to the sensing matrix and noise-free measurement vector rebuilt by SCCS technique. It suggests the great potential of SCCS technique applied in quantum imaging and other quantum optics fields, such as quantum charactering and quantum state tomography to use the information loaded in each photon with high efficiency.