Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Frontiers in Optics

Phase- and Transmission-Based Quantum-Enhanced Resonance Sensing at the Quantum Cramér Rao Bound

Mohammadjavad Dowran, Timothy S. Woodworth, Alberto M. Marino

Published Jan 1, 2020• 0 citations
Publisher

Abstract

We present and compare the ultimate sensitivity bounds with twin beams for resonance schemes based on changes in amplitude and phase of the probing light. Additionally, we present measurement strategies that saturate the ultimate bounds.
DOI
10.1364/fio.2020.fw7c.3

Related papers

Fundamental sensitivity bounds for quantum enhanced optical resonance sensors based on transmission and phase estimation

Mohammadjavad Dowran, Timothy S. Woodworth, Ashok Kumar +1 more

Abstract Quantum states of light can enable sensing configurations with sensitivities beyond the shot-noise limit. In order to better take advantage of available quantum resources and obtain the maximum possible sensitivity, it is necessary to determine fundamental sensitivity limits for different possible configurations for a given sensing system. Here, due to their wide applicability, we focus on optical resonance sensors, which detect a change in a parameter of interest through a resonance shift. We compare their fundamental sensitivity limits set by the quantum Cramér–Rao bound (QCRB) based on the estimation of changes in transmission or phase of a probing bright two-mode squeezed state (bTMSS) of light. We show that the fundamental sensitivity results from an interplay between the QCRB and the transfer function of the system. As a result, for a resonance sensor with a Lorentzian lineshape a phase-based scheme outperforms a transmission-based one for most of the parameter space; however, this is not the case for lineshapes with steeper slopes, such as higher order Butterworth lineshapes. Furthermore, such an interplay results in conditions under which the phase-based scheme provides a higher sensitivity but a smaller degree of quantum enhancement than the transmission-based scheme. We also study the effect of losses external to the sensor on the degree of quantum enhancement and show that for certain conditions, probing with a classical state can provide a higher sensitivity than probing with a bTMSS. Finally, we discuss detection schemes, namely optimized intensity-difference and optimized homodyne detection, that can achieve the fundamental sensitivity limits even in the presence of external losses.

arXiv:2106.07741•Quantum Science and Technology•Nov 1, 2021•6 citations

Towards the ultimate limit in transmission estimation

Alberto M. Marino

The minimum possible uncertainty when estimating a parameter, in this case transmission, is bounded by the quantum Cramér-Rao bound (QCRB). This bound is independent of the measurement technique and as result can be used to quantify how close a measurement is to the optimal one for a given system and probing state, as an optimal measurement saturates the QCRB. The ability to perform transmission measurements through an optical system at the QCRB can lead to enhancements in the calibration of optimal states for interferometers, the characterization of high efficiency photodetectors, or the sensitivity of sensing devices based on transmission, such as plasmonic sensors or spectroscopy. We show theoretically that the ultimate sensitivity limit per photon in the estimation of transmission, achievable with Fock states or vacuum two-mode squeezed states (vTMSS), can be approached through the use of bright quantum states of light, such as bright single-mode squeezed states (bSMSS) or bright two-mode squeezed states (bTMSS). The use of bright quantum states has the advantage that they can be generated with a significantly larger number of photons, which leads to an absolute sensitivity that can be many orders of magnitude larger than the one achieved with Fock states or vTMSS. We identify a measurement strategy that saturates the QCRB for these bright quantum states and shown experimentally that transmission estimation at the QCRB can be achieved with bTMSS through optimized intensity difference measurements.

Optical and Quantum Sensing and Precision Metrology•Mar 4, 2021•0 citations

Transmission estimation at the quantum Cramér-Rao bound with macroscopic quantum light

Timothy S. Woodworth, Carla Hermann-Avigliano, Kam Wai Clifford Chan +1 more

The field of quantum metrology seeks to apply quantum techniques and/or resources to classical sensing approaches with the goal of enhancing the precision in the estimation of a parameter beyond what can be achieved with classical resources. Theoretically, the fundamental minimum uncertainty in the estimation of a parameter for a given probing state is bounded by the quantum Cramér-Rao bound. From a practical perspective, it is necessary to find physical measurements that can saturate this fundamental limit and to show experimentally that it is possible to perform measurements with the required precision to do so. Here we perform experiments that saturate the quantum Cramér-Rao bound for transmission estimation over a wide range of transmissions when probing the system under study with a continuous wave bright two-mode squeezed state. To properly take into account the imperfections in the generation of the quantum state, we extend our previous theoretical results to incorporate the measured properties of the generated quantum state. For our largest transmission level of 84%, we show a 62% reduction over the optimal classical protocol in the variance in transmission estimation when probing with a bright two-mode squeezed state with -8 dB of intensity-difference squeezing. Given that transmission estimation is an integral part of many sensing protocols, such as plasmonic sensing, spectroscopy, calibration of the quantum efficiency of detectors, etc., the results presented promise to have a significant impact on a number of applications in various fields of research.

arXiv:2201.08902•EPJ Quantum Technology•Dec 1, 2022•12 citations

Sensitivity of Quantum-Enhanced Interferometers

Dariya Salykina, Farid Ya Khalili

We review various schemes of quantum-enhanced optical interferometers, both linear (SU(2)) and non-linear (SU(1,1)) ones, as well as hybrid SU(2)/SU(1,1) options, using the unified modular approach based on the Quantum Cramèr–Rao bound (QCRB), and taking into account the practical limitations pertinent to all real-world highly-sensitive interferometers. We focus on three important cases defined by the interferometer symmetry: (i) the asymmetric single-arm interferometer; (ii) the symmetric two-arm interferometer with the antisymmetric phase shifts in the arms; and (iii) the symmetric two-arm interferometer with the symmetric phase shifts in the arms. We show that while the optimal regimes for these cases differ significantly, their QCRBs asymptotically correspond to the same squeezing-enhanced shot noise limit (2), which first appeared in the pioneering work by C. Caves in 1981.We show also that in all considered cases the QCRB can be asymptotically saturated by the standard (direct or homodyne) detection schemes.

arXiv:2212.07708•Symmetry•Mar 22, 2023•11 citations

Quantum enhanced beam displacement estimation: sensitivity limits, optimal probes, and measurement schemes

B. Novák, Pau Colomer, Joseph Zhang +2 more

We investigate the ultimate sensitivity limits for measuring small transverse beam displacements and identify optimal strategies that attain them, using the framework of mode parameter estimation. We contrast two families of states with different resource constraints, using Hermite-Gauss and Laguerre-Gauss mode pairs. First, for fixed total photon number states, the optimal state is identified and we show that it asymptotically approaches a rotated NOON state. The sensitivity bound is compared to that of an asymptotically optimal pure Gaussian state with fixed average photon number. Finally, we propose concrete measurement schemes using the method of moments and show that the twin-Fock state may provide a viable alternative to the rotated NOON state for this task. Our work provides a broader benchmark for developing practical strategies for spatial sensing at the quantum limit.

arXiv:2611.08427•Nov 5, 2026•0 citations

Resonator-Based Phase Sensing Beyond the Standard Quantum Limit with Classical Coherent Light

Yu Tao, Jingzheng Huang, Guihua Zeng

We investigate resonator-based phase sensing strategy with classical coherent light and show that properly designed resonator strategies can surpass the standard quantum limit, establishing new precision bounds and practical protocols for high-resolution optical metrology applications.

Conference on Lasers and Electro-Optics Pacific Rim (CLEO-PR)•Aug 1, 2026•0 citations
Abstract Quantum states of light can enable sensing configurations with sensitivities beyond the shot-noise limit. In order to better take advantage of available quantum resources and obtain the maximum possible sensitivity, it is necessary to determine fundamental sensitivity limits for different possible configurations for a given sensing system. Here, due to their wide applicability, we focus on optical resonance sensors, which detect a change in a parameter of interest through a resonance shift. We compare their fundamental sensitivity limits set by the quantum Cramér–Rao bound (QCRB) based on the estimation of changes in transmission or phase of a probing bright two-mode squeezed state (bTMSS) of light. We show that the fundamental sensitivity results from an interplay between the QCRB and the transfer function of the system. As a result, for a resonance sensor with a Lorentzian lineshape a phase-based scheme outperforms a transmission-based one for most of the parameter space; however, this is not the case for lineshapes with steeper slopes, such as higher order Butterworth lineshapes. Furthermore, such an interplay results in conditions under which the phase-based scheme provides a higher sensitivity but a smaller degree of quantum enhancement than the transmission-based scheme. We also study the effect of losses external to the sensor on the degree of quantum enhancement and show that for certain conditions, probing with a classical state can provide a higher sensitivity than probing with a bTMSS. Finally, we discuss detection schemes, namely optimized intensity-difference and optimized homodyne detection, that can achieve the fundamental sensitivity limits even in the presence of external losses.
The minimum possible uncertainty when estimating a parameter, in this case transmission, is bounded by the quantum Cramér-Rao bound (QCRB). This bound is independent of the measurement technique and as result can be used to quantify how close a measurement is to the optimal one for a given system and probing state, as an optimal measurement saturates the QCRB. The ability to perform transmission measurements through an optical system at the QCRB can lead to enhancements in the calibration of optimal states for interferometers, the characterization of high efficiency photodetectors, or the sensitivity of sensing devices based on transmission, such as plasmonic sensors or spectroscopy. We show theoretically that the ultimate sensitivity limit per photon in the estimation of transmission, achievable with Fock states or vacuum two-mode squeezed states (vTMSS), can be approached through the use of bright quantum states of light, such as bright single-mode squeezed states (bSMSS) or bright two-mode squeezed states (bTMSS). The use of bright quantum states has the advantage that they can be generated with a significantly larger number of photons, which leads to an absolute sensitivity that can be many orders of magnitude larger than the one achieved with Fock states or vTMSS. We identify a measurement strategy that saturates the QCRB for these bright quantum states and shown experimentally that transmission estimation at the QCRB can be achieved with bTMSS through optimized intensity difference measurements.
The field of quantum metrology seeks to apply quantum techniques and/or resources to classical sensing approaches with the goal of enhancing the precision in the estimation of a parameter beyond what can be achieved with classical resources. Theoretically, the fundamental minimum uncertainty in the estimation of a parameter for a given probing state is bounded by the quantum Cramér-Rao bound. From a practical perspective, it is necessary to find physical measurements that can saturate this fundamental limit and to show experimentally that it is possible to perform measurements with the required precision to do so. Here we perform experiments that saturate the quantum Cramér-Rao bound for transmission estimation over a wide range of transmissions when probing the system under study with a continuous wave bright two-mode squeezed state. To properly take into account the imperfections in the generation of the quantum state, we extend our previous theoretical results to incorporate the measured properties of the generated quantum state. For our largest transmission level of 84%, we show a 62% reduction over the optimal classical protocol in the variance in transmission estimation when probing with a bright two-mode squeezed state with -8 dB of intensity-difference squeezing. Given that transmission estimation is an integral part of many sensing protocols, such as plasmonic sensing, spectroscopy, calibration of the quantum efficiency of detectors, etc., the results presented promise to have a significant impact on a number of applications in various fields of research.
We review various schemes of quantum-enhanced optical interferometers, both linear (SU(2)) and non-linear (SU(1,1)) ones, as well as hybrid SU(2)/SU(1,1) options, using the unified modular approach based on the Quantum Cramèr–Rao bound (QCRB), and taking into account the practical limitations pertinent to all real-world highly-sensitive interferometers. We focus on three important cases defined by the interferometer symmetry: (i) the asymmetric single-arm interferometer; (ii) the symmetric two-arm interferometer with the antisymmetric phase shifts in the arms; and (iii) the symmetric two-arm interferometer with the symmetric phase shifts in the arms. We show that while the optimal regimes for these cases differ significantly, their QCRBs asymptotically correspond to the same squeezing-enhanced shot noise limit (2), which first appeared in the pioneering work by C. Caves in 1981.We show also that in all considered cases the QCRB can be asymptotically saturated by the standard (direct or homodyne) detection schemes.
We investigate the ultimate sensitivity limits for measuring small transverse beam displacements and identify optimal strategies that attain them, using the framework of mode parameter estimation. We contrast two families of states with different resource constraints, using Hermite-Gauss and Laguerre-Gauss mode pairs. First, for fixed total photon number states, the optimal state is identified and we show that it asymptotically approaches a rotated NOON state. The sensitivity bound is compared to that of an asymptotically optimal pure Gaussian state with fixed average photon number. Finally, we propose concrete measurement schemes using the method of moments and show that the twin-Fock state may provide a viable alternative to the rotated NOON state for this task. Our work provides a broader benchmark for developing practical strategies for spatial sensing at the quantum limit.