High-impedance quantum circuit elements consisting of large inductors with small self-capacitance, are important building blocks in quantum circuit elements, with many potential applications. We present thin-film niobium (Nb) spiral resonators exhibiting large geometric inductance, high critical magnetic fields, and high single-photon quality factors. These low-loss geometric inductors can be a compelling alternative to kinetic inductors to create high-impedance superconducting devices for applications that require magnetic fields. We measure the temperature and magnetic-field-dependent losses and find that the high-impedance resonators maintain an intrinsic quality factor above approximately 105 for parallel magnetic fields of up to 1 T. These properties make spiral Nb resonators a promising candidate for quantum devices that require circuit elements with high impedance and magnetic-field resilience. The quantum device we present, incorporating these spirals, is the inductively shunted transmon qudit. The transmon is a widely used superconducting qubit. We develop and optimize a fabrication procedure for transmons, and our primary qubit measurements indicate that we have successfully fabricated qubits. We develop and optimize a fabrication procedure for transmons with Al/AlOx/Al Josephson junctions. For the rest of the circuit, we start with Nb and then shift to Ta due to its superior material properties and the more feasible fabrication procedure it allows using our existing fabrication capabilities. Finally, we introduce the inductively shunted transmon, a transmon shunted by a linear inductor. We show numerically that it could provide highly coherent qudit operations. Then, we propose a simple design to shunt the previously introduced spirals to the transmons.
I discuss the design, fabrication and measurement at millikelvin-temperatures of Al/AlO
x/Al Josephson junction-based transmon qubits coupled to superconducting thin-film lumped element microwave resonators made of aluminum on sapphire. The resonators had a center frequency of around
6GHz, and a total quality factor ranging from 15,000 to 70,000 for the various devices. The area of the transmon junctions was about
150nm×150nm and with Josephson energy
EJ such that
10GHz≤EJ/h≤30GHz. The charging energy of the transmons arising mostly from the large interdigital shunt capacitance, was
Ec/h≈300MHz. I present microwave spectroscopy of the devices in the strongly dispersive regime of circuit quantum electrodynamics. In this limit the ac Stark shift due to a single photon in the resonator is greater than the linewidth of the qubit transition. When the resonator is driven coherently using a coupler tone, the transmon spectrum reveals individual ``photon number'' peaks, each corresponding to a single additional photon in the resonator. Using a weighted average of the peak heights in the qubit spectrum, I calculated the average number of photons
nˉ in the resonator. I also observed a nonlinear variation of
nˉ with the applied power of the coupler tone
Prf. I studied this nonlinearity using numerical simulations and found good qualitative agreement with data. In the absence of a coherent drive on the resonator, a thermal population of
5.474GHz photons in the resonator, at an effective temperature of
120mK resulted in a weak
n=1 thermal photon peak in the qubit spectrum. In the presence of independent coupler and probe tones, the
n=1 thermal photon peak revealed an Autler-Townes splitting. The observed effect was explained accurately using the four lowest levels of the dispersively dressed Jaynes-Cummings transmon-resonator system, and numerical simulations of the steady-state master equation for the coupled system. I also present time-domain measurements on transmons coupled to lumped-element resonators. From
T1 and Rabi oscillation measurements, I found that my early transmon devices (called design LEv5) had lifetimes (
T1∼1μs) limited by strong coupling to the
50Ω transmission line. This coupling was characterized by the the rate of change of the Rabi oscillation frequency with the change in the drive voltage (
dfRabi/dV) -- also termed the Rabi coupling to the drive. I studied the design of the transmon-resonator system using circuit analysis and microwave simulations with the aim being to reduce the Rabi coupling to the drive. By increasing the resonance frequency of the resonator
ωr/2π from 5.4
GHz to 7.2
GHz, lowering the coupling of the resonator to the transmission line and thereby increasing the external quality factor
Qe from 20,000 to 70,000, and reducing the transmon-resonator coupling
g/2π from 70
MHz to 40
MHz, I reduced the Rabi coupling to the drive by an order of magnitude (
∼ factor of 20). The
T1∼4μs of devices in the new design (LEv6) was longer than that of the early devices, but still much shorter than the lifetimes predicted from Rabi coupling, suggesting the presence of alternative sources of noise causing qubit relaxation. Microwave simulations and circuit analysis in the presence of a dielectric loss tangent
tanδ≃5×10−6 agree reasonably well with the measured
T1 values, suggesting that surface dielectric loss may be causing relaxation of transmons in the new designs.
We present a method for in situ temperature measurement of superconducting quantum circuits, by using the first three levels of a transmon device to which we apply a sequence of π gates. Our approach employs projective dispersive readout and utilizes the basic properties of the density matrix associated with thermal states. This method works with an averaging readout scheme and does not require a single-shot readout setup. We validate this protocol by performing thermometry in the range of 50–200 mK, corresponding to a range of residual populations 1%–20% for the first excited state and 0.02%–3% for the second excited state.