The optical light shift effect is an all-optical technique to create magnetic bias fields to determine the vector components of the magnetic field using a scalar optically pumped magnetometer. We show that the measurement of the induced bias fields is affected by the response pattern of the scalar magnetometer. The sensitivity of the magnetometer affects the minimum total field resolution as well as the angular resolution of the vector measurement. Three configurations of multiple-laser, optically pumped cesium vapor vector magnetometers are characterized for their spatial sensitivity patterns. Each configuration has a unique response level as a function of the relative magnetic field orientation. Thus, the formulations used for angular determination are dependent on the magnetometer configuration, and the angular resolution of the vector measurement is dependent on the relative angle between the magnetic field and the optical probe beam. The spatial dependence of the light shift signals is measured, and the equations describing their responses are presented for each configuration. Equations for determining the field angles from the bias field responses are derived.
The optical light shift effect is an all-optical technique to create magnetic bias fields to determine the vector components of the magnetic field using a scalar optically pumped magnetometer. We show that the measurement of the induced bias fields is affected by the response pattern of the scalar magnetometer. The sensitivity of the magnetometer affects the minimum total field resolution as well as the angular resolution of the vector measurement. Three configurations of multiple-laser, optically pumped cesium vapor vector magnetometers are characterized for their spatial sensitivity patterns. Each configuration has a unique response level as a function of the relative magnetic field orientation. Thus, the formulations used for angular determination are dependent on the magnetometer configuration, and the angular resolution of the vector measurement is dependent on the relative angle between the magnetic field and the optical probe beam. The spatial dependence of the light shift signals is measured, and the equations describing their responses are presented for each configuration. Equations for determining the field angles from the bias field responses are derived.
Atomic vapor magnetometers have demonstrated very high sensitivity to the magnitude of the magnetic field. Vector field measurements are possible using bias fields applied to the vapor. For remote operation, the bias field can be generated using the optical light shift (LS) effect created with an optical beam delivered through optical fiber. Here, it is shown that the optical frequency of the LS effect for an optically pumped vapor vector magnetometer causes an angular error in the measured field orientation when it is tuned near the absorption resonances, countering the benefit of higher response. This angle-shifting effect is dependent on the LS beam power. The LS response, normalized to the LS power, is higher for lower powers due to a saturation effect but also shows a dependence on the LS optical frequency. We show that it is necessary to carefully choose the LS optical frequency and power to maximize the LS effect while avoiding potential angular error.
Vector field measurement is demonstrated with an all-optical scalar atomic magnetometer using intrinsic parameters related to its scalar operation. The Bell-Bloom type atomic magnetometer measures the Larmor precession of cesium atoms through on-resonant absorption of a probe beam. While the AC component of the probe signal is used for the field magnitude measurement, the probe DC signal contains information about the polar angle, defined as the angle between the magnetic field and the probe beam. Additional polar angle information is obtained from the light-shift-induced magnetic field caused by the frequency modulation of the probe beam. With a measurement time of 100 ms, better than 0.02° sensitivity has been achieved using a commercial miniaturized sensor at the optimal sensor orientation. The angle measurement accuracy is checked against an optical encoder over the entire polar angle range of 0°–180°. Better than 1° error is recorded over most set polar angles. Azimuthal angle measurement is also exhibited with two orthogonally oriented sensors.
Based on power modulation of a pump laser and precessional projection detection, we present an all-optical vector magnetometer of cesium, which has a demonstrated magnitude sensitivity of 80 fT/Hz 1/2 and an orientation sensitivity of 0.1°/Hz 1/2 . In the device, four main factors are measured experimentally, which are the Larmor precession frequency of a polarized magnetic moment that depends on the modulus of the measured magnetic field only, two phase shifts and amplitude ratio of the precession projection in the two probe directions relative to the magnetic field orientation. This kind of magnetometer with high sensitivity in the range of the spatial angle is suitable for solving the inverse problem and geomagnetic navigation.
In this work, we look to compare three methods of feedback for the ultimate purpose of measuring the transverse vector components of a magnetic field using a synchronous light-pulse atomic scalar magnetometer with a few tens of fT/Hz sensitivity in Earth-field-scale magnetic environments. By applying modulation in the magnetic field to orthogonal axes, the respective vector components may, in principle, be separated from the scalar measurement. Success of this technique depends in significant part on the ability to measure and respond to these perturbations with low measurement uncertainty. Using high-speed least-squares fitting, the phase response of the atomic spins relative to the first harmonic of the optical pump pulse repetition rate is monitored and correspondingly adjusted into resonance with the natural Larmor precession frequency. This paper seeks to motivate and compare three distinct methods of feedback for this purpose. As a first step toward the full development of this technique, the present work uses a simplified version with modulation applied only along the bias field. All three methods investigated herein are shown to provide results that match well with the scalar magnetometer measurements and to depend on both the applied modulation amplitude and optimal feedback response to achieve low relative uncertainty.
A scalar magnetic field sensor based on a millimeter-size Rb87 vapor cell is described. The magnetometer uses nearly copropagating pump and probe laser beams, amplitude modulation of the pump beam, and detection through monitoring the polarization rotation of the detuned probe beam. The circularly polarized pump laser resonantly drives a spin precession in the alkali atoms at the Larmor frequency. A modulation signal on the probe laser polarization is detected with a lock-in amplifier. Since the Larmor precession is driven all-optically, potential cross talk between sensors is minimized. And since the pump light is turned off during most of the precession cycle, large offsets of the resonance, typically present in a single-beam Bell–Bloom scheme, are avoided. At the same time, relatively high sensitivities can be reached even in millimeter-size vapor cells: The magnetometer achieves a sensitivity of 1 pT/Hz1/2 in a sensitive volume of 16 mm3, limited by environmental noise. When a gradiometer configuration is used to cancel the environmental noise, the magnetometer sensitivity reaches 300 fT/Hz1/2. We systematically study the dependence of the magnetometer performance on the optical duty cycles of the pump light and find that better performance is achieved with shorter duty cycles, with the highest values measured at 1.25% duty cycle.
The main focus of this dissertation is investigation of vector AC Stark shifts (light shifts) in evacuated 133Cs paraffin-coated cells. Although light shifts in alkali atoms have been investigated since 1960s, the effect of laser-induced vector light shifts (VLS) in paraffin-coated cells is little explored in literature. The works considering light shift effects primarily focus on transitions relevant for atomic clocks, or magnetometers using buffer gas cells, or magnetometers using broad-spectrum alkali metal lamps. This work, on the other hand, focuses on light shifts in a setup shared by finite-field optical magnetometers that use paraffin-coated sensor cells, as well as on their impact on sensitivity and accuracy of these devices.Along with describing the light shifts, this work presents several techniques that take advantage of the VLS to improve atomic magnetometers as a tool. The proposed techniques eliminate the need for oscillating radio-frequency magnetic fields and replace them with well contained laser beams. This can benefit applications where non-magnetic sensors are needed and stray fields are highly undesirable, such as the search for a permanent electric dipole moment of the neutron.This dissertation includes two such projects, the all-optical vector magnetometer and the rf magnetometer driven by a fictitious magnetic field. In the first project a finite-field optical magnetometer, which is normally a scalar sensor, is augmented with two power-modulated orthogonal laser beams that provide the directional sensitivity. The sensor exhibits a demonstrated rms noise floor of 50 fT/√Hz in measurement of the field magnitude and 0.5 mrad/√Hz in the field direction. Elimination of technical noise would improve these sensitivities to 12 fT/√Hz and 5 μrad/√Hz, respectively. In the second project, the atomic precession in a scalar 133Cs magnetometer is driven by an effective oscillating magnetic field provided by the AC Stark shift of an intensity-modulated laser beam. The demonstrated sensitivity of this magnetometer is 40 fT/√Hz rms, which is equivalent to the conventional coil-driven scalar magnetometer we built sharing the same setup.The Appendix includes documentation on the custom-built polarimeter used in the experiments and the frequency response of the magnetic sensor head.